1…   4…   8…   8.2…   8.2.3…   8.3…   8.3.4…   8.4…   8.4.3…   8.5…   8.7…   8.8…   8.10…   8.12…   8.17…   9…   9.2…   9.2.2…   9.2.3…   9.2.4…   9.2.6…   9.2.7…   9.2.9…   9.2.11…   9.2.16…   9.2.17…   9.3…   9.3.1.21…   9.3.1.41…   9.3.1.61…   9.3.1.81…   9.3.1.101…   9.3.1.121…   9.3.1.141…   9.3.1.161…   9.3.1.181…   9.3.1.205…   9.3.1.222…   9.3.1.245…   9.3.2…   9.3.3…   9.3.3.21…   9.3.3.42…   9.3.4…   9.3.4.10…   9.3.5…   9.4…   9.4.4   9.4.5   9.4.6…   9.5…   10…

 

9.3.1.141  Paging Assistance Data for CE Capable UE |R16|p. 263

This IE provides Assistance Data for paging CE capable UE.
IE/Group Name Pre­sence Range IE type and reference Semantics description
Global Cell IDME-UTRA CGI
9.3.1.9
Coverage Enhancement LevelMOCTET STRINGIncludes either the UEPagingCoverageInformation message as defined in TS 36.331, or the UEPagingCoverageInformation-NB message as defined in TS 36.331.
Up

9.3.1.142  UE Radio Capability ID |R16|p. 263

This IE contains the UE Radio Capability ID.
IE/Group Name Pre­sence Range IE type and reference Semantics description
UE Radio Capability IDMOCTET STRINGDefined in TS 23.003.
Up

9.3.1.143  WUS Assistance Information |R16|p. 264

This IE provides WUS Assistance Information to be used by the NG-RAN node for determining the WUS group for the UE.
IE/Group Name Pre­sence Range IE type and reference Semantics description
Paging Probability InformationMENUMERATED (p00, p05, p10, p15, p20, p25, p30, p35, p40, p45, p50, p55, p60, p65, p70, p75, p80, p85, p90, p95, p100, …)Unit: percentage
Up

9.3.1.144  UE Differentiation Information |R16|p. 264

This IE is generated by the AMF based on the UE subscription information, it provides the Expected UE Behavior Information.
IE/Group Name Pre­sence Range IE type and reference Semantics description
Periodic Communication IndicatorOENUMERATED (periodically, on demand, …)This IE indicates whether the UE communicates periodically or not, e.g. only on demand.
Periodic TimeOINTEGER (1..3600, …)This IE indicates the interval time of periodic communication, the unit is: second
Scheduled Communication Time0..1This IE indicates the time zone and day of the week when the UE is available for communication.
>Day of WeekOBIT STRING (SIZE(7)) Each position in the bitmap represents a day of the week:
first bit = Mon, second bit =Tue, third bit =Wed, and so on. Value '1' indicates 'scheduled. Value '0' indicates 'not scheduled'.
If Day-Of-Week is not provided, this is interpreted as every day of the week.
>Time of Day StartOINTEGER (0..86399, …) This IE indicates the time to start of the day, each value represents the corresponding second since 00:00 of the day.
If Time-Of-Day-Start is not provided, starting time is start of the day(s) indicated by Day-Of-Week-Mask.
>Time of Day EndOINTEGER (0..86399, …) This IE indicates the time to start of the day, each value represents the corresponding second since 00:00 of the day. The value of this IE should be bigger than the value of Time of Day Start IE.
If Time-Of-Day-End is not provided, ending time is end of the day(s) indicated by Day-Of-Week-Mask.
Stationary IndicationOENUMERATED (stationary, mobile, …)
Traffic ProfileOENUMERATED (single packet, dual packets, multiple packets, …) "single packet" indicates single packet transmission (UL or DL), "dual packets" indicates dual packet transmission (UL with subsequent DL, or DL with subsequent UL), "multiple packets" indicates multiple packets transmission.
Battery IndicationOENUMERATED (battery powered, battery powered not rechargeable or replaceable, not battery powered, …) "battery powered" indicates that the UE is battery powered and the battery is rechargeable/replaceable, "battery powered not rechargeable or replaceable" indicates that the UE is battery powered but the battery is not rechargeable/replaceable, "not battery powered" indicates that the UE is not battery powered.
Up

9.3.1.145  NB-IoT UE Priority |R16|p. 266

This IE provides the NB-IoT UE Priority and to be used by the NG-RAN to prioritise between UEs accessing via NB-IoT.
IE/Group Name Pre­sence Range IE type and reference Semantics description
NB-IoT UE PriorityMINTEGER (0..255, …) Lower value indicates higher priority.
Up

9.3.1.146  NR V2X Services Authorized |R16|p. 266

This IE provides information on the authorization status of the UE to use the NR sidelink for V2X services.
IE/Group Name Pre­sence Range IE type and reference Semantics description
Vehicle UEOENUMERATED (authorized, not authorized, ...)Indicates whether the UE is authorized as Vehicle UE
Pedestrian UEOENUMERATED (authorized, not authorized, ...)Indicates whether the UE is authorized as Pedestrian UE
Up

9.3.1.147  LTE V2X Services Authorized |R16|p. 266

This IE provides information on the authorization status of the UE to use the LTE sidelink for V2X services.
IE/Group Name Pre­sence Range IE type and reference Semantics description
Vehicle UEOENUMERATED (authorized, not authorized, ...)Indicates whether the UE is authorized as Vehicle UE
Pedestrian UEOENUMERATED (authorized, not authorized, ...)Indicates whether the UE is authorized as Pedestrian UE
Up

9.3.1.148  NR UE Sidelink Aggregate Maximum Bit Rate |R16|p. 266

This IE provides information on the Aggregate Maximum Bitrate of the UE's sidelink communication.
IE/Group Name Pre­sence Range IE type and reference Semantics description
NR UE Sidelink Aggregate Maximum Bit RateMBit Rate
9.3.1.4
Value 0 is not valid, and considered as a logical error by the receiving NG-RAN node.
Up

9.3.1.149  LTE UE Sidelink Aggregate Maximum Bit Rate |R16|p. 266

This IE provides information on the Aggregate Maximum Bitrate of the UE's sidelink communication for LTE V2X services.
IE/Group Name Pre­sence Range IE type and reference Semantics description
LTE UE Sidelink Aggregate Maximum Bit RateMBit Rate
9.3.1.4
Value 0 is not valid, and considered as a logical error by the receiving NG-RAN node.
Up

9.3.1.150  PC5 QoS Parameters |R16|p. 267

This IE provides information on the PC5 QoS parameters of the UE's sidelink communication for NR PC5.
IE/Group Name Pre­sence Range IE type and reference Semantics description
PC5 QoS Flow List1
>PC5 QoS Flow Item1..<maxnoofPC5QoSFlows>
>>PQI MINTEGER (0..255, …)PQI is a special 5QI as specified in TS 23.501.
>>PC5 Flow Bit Rates0..1Only applies for GBR QoS Flows.
>>>Guaranteed Flow Bit RateMBit Rate
9.3.1.4
Guaranteed Bit Rate for the PC5 QoS flow. Details in TS 23.501.
>>>Maximum Flow Bit RateMBit Rate
9.3.1.4
Maximum Bit Rate for the PC5 QoS flow. Details in TS 23.501.
>>RangeOENUMERATED (m50, m80, m180, m200, m350, m400, m500, m700, m1000, …)Only applies for groupcast.
PC5 Link Aggregate Bit RatesOBit Rate
9.3.1.4
Only applies for non-GBR QoS Flows.
Range bound Explanation
maxnoofPC5QoSFlowsMaximum no. of PC5 QoS flows allowed towards one UE. Value is 2048.
Up

9.3.1.151  Alternative QoS Parameters Set List |R16|p. 267

This IE contains alternative sets of QoS parameters which the NG-RAN node can indicate to be fulfilled when notification control is enabled and it cannot fulfil the requested list of QoS parameters.
IE/Group Name Pre­sence Range IE type and reference Semantics description
Alternative QoS Parameters Set Item1..<maxnoofQoSparaSets>
>Alternative QoS Parameters Set IndexM 9.3.1.152
>Guaranteed Flow Bit Rate DownlinkOBit Rate
9.3.1.4
>Guaranteed Flow Bit Rate UplinkOBit Rate
9.3.1.4
>Packet Delay Budget O 9.3.1.80
>Packet Error Rate O 9.3.1.81
Range bound Explanation
maxnoofQoSparaSetsMaximum no. of alternative sets of QoS Parameters allowed for the QoS profile. Value is 8.
Up

9.3.1.152  Alternative QoS Parameters Set Index |R16|p. 268

This IE indicates the QoS parameters set which can currently be fulfilled.
IE/Group Name Pre­sence Range IE type and reference Semantics description
Alternative QoS Parameters Set IndexMINTEGER (1..8, ...)Indicates the index of the item within the the Alternative QoS Parameters Set List IE corresponding to the currently fulfilled alternative QoS parameters set.
Up

9.3.1.153  Alternative QoS Parameters Set Notify Index |R16|p. 268

This IE indicates the QoS parameters set which can currently be fulfilled.
IE/Group Name Pre­sence Range IE type and reference Semantics description
Alternative QoS Parameters Set Notify IndexMINTEGER (0..8, ...)Indicates the index of the item within the the Alternative QoS Parameters Set List IE corresponding to the currently fulfilled alternative QoS parameters set. Value 0 indicates that NG-RAN cannot even fulfil the lowest alternative parameters set.
Up

9.3.1.154  E-UTRA Paging eDRX Information |R16|p. 268

This IE indicates the E-UTRA Paging eDRX parameters as defined in TS 36.304.
IE/Group Name Pre­sence Range IE type and reference Semantics description
E-UTRA Paging eDRX CycleMENUMERATED (hfhalf, hf1, hf2, hf4, hf6, hf8, hf10, hf12, hf14, hf16, hf32, hf64, hf128, hf256, …)TeDRX defined in TS 36.304. Unit: [number of hyperframes].
E-UTRA Paging Time WindowOENUMERATED (s1, s2, s3, s4, s5, s6, s7, s8, s9, s10, s11, s12, s13, s14, s15, s16, …)Unit: [1.28 second].
Up

9.3.1.155  CE-mode-B Restricted |R16|p. 268

This IE provides information on the restriction information of using Coverage Enhancement Mode B.
IE/Group Name Pre­sence Range IE type and reference Semantics description
CE-mode-B RestrictedMENUMERATED (restricted, not-restricted, ...)Indicates whether the UE is restricted to use coverage enhancement. Value "restricted" indicates that the UE is not allowed to use coverage enhancement mode B. Value "not-restricted" indicates that the UE is allowed to use coverage enhancement mode B.
Up

9.3.1.156  CE-mode-B Support Indicator |R16|p. 269

This IE indicates whether CE-mode-B as specified in TS 36.306 is supported for the UE.
IE/Group Name Pre­sence Range IE type and reference Semantics description
CE-mode-B Support IndicatorMENUMERATED (supported, …)
Up

9.3.1.157  LTE-M Indication |R16|p. 269

This IE is provided by the NG-RAN node to inform that the UE indicates category M1 or M2 in its UE Radio Capability.
IE/Group Name Pre­sence Range IE type and reference Semantics description
LTE-M IndicationMENUMERATED (LTE-M, ...)
Up

9.3.1.158  Suspend Request Indication |R16|p. 269

This IE indicates that the NG-RAN node requests immediate transition to RRC idle with suspend, as specified in TS 23.502.
IE/Group Name Pre­sence Range IE type and reference Semantics description
Suspend Request IndicationMENUMERATED (suspend-requested, …)
Up

9.3.1.159  Suspend Response Indication |R16|p. 269

This IE is used by the AMF to inform the NG-RAN node to suspend the UE and send it to RRC_IDLE, as specified in TS 23.502.
IE/Group Name Pre­sence Range IE type and reference Semantics description
Suspend Response IndicationMENUMERATED (suspend-indicated, …)
Up

9.3.1.160  UE User Plane CIoT Support Indicator |R16|p. 269

This IE indicates whether User Plane CIoT 5GS Optimisation as specified in TS 23.501 is supported for the UE.
IE/Group Name Pre­sence Range IE type and reference Semantics description
UE User Plane CIoT Support IndicatorMENUMERATED (supported, …)
Up