Tech-invite3GPPspaceIETFspace
21222324252627282931323334353637384‑5x

Content for  TS 38.331  Word version:  18.0.0

Top   Top   Up   Prev   Next
1…   4…   5…   5.2.2.4…   5.3…   5.3.3…   5.3.5…   5.3.5.5…   5.3.5.6…   5.3.5.7…   5.3.5.13…   5.3.5.17…   5.3.6…   5.3.8…   5.3.13…   5.3.14…   5.4…   5.5…   5.5.3…   5.5.4…   5.5.4.15…   5.5.4.23…   5.5.5…   5.5a…   5.7…   5.7.4…   5.7.8…   5.7.12…   5.8…   5.8.9…   5.8.9.2…   5.8.9.8…   5.8.10…   5.8.11…   5.9…   5.10…   6…   6.2.2…   6-2-2-23…   6-2-2-27…   6-2-2-43…   6-2-2-47…   6.3…   6.3.2…   6-3-2-27…   6-3-2-49…   6-3-2-73…   6-3-2-95…   6-3-2-108…   6-3-2-134…   6-3-2-162…   6-3-2-188…   6-3-2-213…   6-3-2-243…   6-3-2-271…   6-3-2-297…   6-3-2-341…   6.3.3…   6-3-3-25…   6-3-3-51…   6.3.4…   6.3.5…   6-3-5-25…   6.3.6…   6.4…   7…   9…   11…   A…   A.4…   B…

 

 –  SL-LogicalChannelConfigp. 1346

The IE SL-LogicalChannelConfig is used to configure the sidelink logical channel parameters.
SL-LogicalChannelConfig information element
SL-LogicalChannelConfig field descriptions
sl-AllowedCarriers
If present, SL MAC SDUs from this logical channel can only be mapped to the sidelink carriers indicated in this list. Otherwise, SL MAC SDUs from this logical channel can be mapped to any configured sidelink carriers. The value 1 corresponds to the frequency of first entry in sl-FreqInfoList broadcast in SIB12, the value 2 corresponds to the frequency of first entry in sl-FreqInfoListSizeExt broadcast in SIB12, the value 3 corresponds to the frequency of second entry in sl-FreqInfoListSizeExt broadcast in SIB12 and so on.
sl-AllowedCG-List
This restriction applies only when the SL grant is a configured grant. If present, SL MAC SDUs from this logical channel can only be mapped to the indicated configured grant configuration. If the size of the sequence is zero, then SL MAC SDUs from this logical channel cannot be mapped to any configured grant configurations. If the field is not present, SL MAC SDUs from this logical channel can be mapped to any configured grant configurations. If the field sl-ConfiguredGrantType1Allowed is present, only those sidelink configured grant type 1 configurations indicated in this sequence are allowed for use by this sidelink logical channel; otherwise, this sequence shall not include any sidelink configured grant type 1 configuration. Corresponds to "sl-AllowedCG-List" as specified in TS 38.321.
sl-AllowedSCS-List
If present, indicate the numerology of UL-SCH resources that this sidelink logical channel is mapped to, when checking the SR trigger condition. Corresponds to 'sl-AllowedSCS-List' in TS 38.321.
sl-BucketSizeDuration
Value in ms. ms5 corresponds to 5 ms, value ms10 corresponds to 10 ms, and so on.
sl-ChannelAccessPriority
Indicates the Channel Access Priority Class (CAPC), as specified in TS 38.300, to be used on sidelink transmissions for operation with shared spectrum channel access in FR1. The network configures this field only for DRBs.
sl-ConfiguredGrantType1Allowed
If present and set to true, or if the capability lcp-RestrictionSidelink as specified in TS 38.306 is not indicated, SL MAC SDUs from this sidelink logical channel can be transmitted on a sidelink configured grant type 1. Otherwise, SL MAC SDUs from this logical channel cannot be transmitted on a sidelink configured grant type 1. Corresponds to 'sl-configuredGrantType1Allowed' in TS 38.321.
sl-HARQ-FeedbackEnabled
Network always includes this field. It indicates the HARQ feedback enabled/disabled restriction in LCP for this sidelink logical channel. If set to enabled, the sidelink logical channel will be multiplexed only with a logical channel which enabling the HARQ feedback. If set to disabled, the sidelink logical channel cannot be multiplexed with a logical channel which enabling the HARQ feedback. Corresponds to 'sl-HARQ-FeedbackEnabled' in TS 38.321. If this field of at least one sidelink logical channel for the UE is set to enabled, sl-PSFCH-Config should be mandatory present in configuration SL-ResourcePool of at least one of the sidelink resource pools.
sl-LogicalChannelGroup
ID of the sidelink logical channel group, as specified in TS 38.321, which the sidelink logical channel belongs to.
sl-LogicalChannelSR-DelayTimerApplied
Indicates whether to apply the delay timer for SR transmission for this sidelink logical channel. Set to false if logicalChannelSR-DelayTimer is not included in sl-BSR-Config.
sl-MaxPUSCH-Duration
If present, indicate the maximum PUSCH duration of UL-SCH resources that this sidelink logical channel is mapped to, when checking the SR trigger condition. Corresponds to "sl-MaxPUSCH-Duration" in TS 38.321.
sl-PrioritisedBitRate
Value in kiloBytes/s. Value kBps0 corresponds to 0 kiloBytes/s, value kBps8 corresponds to 8 kiloBytes/s, value kBps16 corresponds to 16 kiloBytes/s, and so on.
sl-Priority
Sidelink logical channel priority, as specified in TS 38.321.
sl-SchedulingRequestId
If present, it indicates the scheduling request configuration applicable for this sidelink logical channel, as specified in TS 38.321.
Conditional Presence Explanation
CONNECTEDThis field is optionally present, Need M, in an RRCReconfiguration message, for a SL DRB with additional RLC bearer being configured. The field is absent otherwise.
Up

 –  SL-L2RelayUE-Configp. 1349

The IE SL-L2RelayUE-Config is used to configure L2 U2N relay operation related configurations used by L2 U2N Relay UE, or L2 U2U relay operation related configurations used by L2 U2U Relay UE.
SL-L2RelayUE-Config information element
SL-L2RelayUE-Config field descriptions
sl-RemoteUE-ToAddModList
List of L2 U2N Remote UEs to be added and modified to the L2 U2N Relay UE.
sl-RemoteUE-ToReleaseList
List of L2 U2N Remote UEs to be released by the L2 U2N Relay UE.
sl-U2U-RemoteUE-ToAddModList
List of L2 U2U Remote UEs for which the related configuration is to be added and modified to the L2 U2U Relay UE.
sl-U2U-RemoteUE-ToReleaseList
List of L2 U2U Remote UEs for which the related configuration is to be released by the L2 U2U Relay UE.
sl-U2U-SourceRemoteUE-ToAddModList
List of Source L2 U2U Remote UEs for which the related configuration is to be added and modified.
sl-U2U-SourceRemoteUE-ToReleaseList
List of Source L2 U2U Remote UEs for which the related configuration is to be released.
Up

 –  SL-L2RemoteUE-Configp. 1350

The IE SL-L2RemoteUE-Config is used to configure L2 U2N relay operation related configurations used by L2 U2N Remote UE, or L2 U2U relay operation related configurations used by L2 U2U Remote UE.
SL-L2RemoteUE-Config information element
SL-L2RemoteUE-Config field descriptions
sl-SRAP-ConfigRemote
Indicates SRAP configuration used for L2 U2N Remote UE.
sl-UEIdentityRemote
Indicates the C-RNTI to the L2 U2N Remote UE.
sl-U2U-RelayUE-ToAddModList
List of L2 U2U Relay UEs for which the related configuration is to be added and modified to the L2 U2U Remote UE.
sl-U2U-RelayUE-ToReleaseList
List of L2 U2U Relay UEs for which the related configuration is to be released by the L2 U2U Remote UE.
sl-U2U-PeerRemoteUE-ToAddModList
List of Peer L2 U2U Remote UEs for which the related configuration is to be added and modified.
sl-U2U-PeerRemoteUE-ToReleaseList
List of Peer L2 U2U Remote UEs for which the related configuration is to be released.
Conditional Presence Explanation
FirstRRCReconfigThis field is mandatory present in the first RRCReconfiguration for L2 U2N Remote UE when PCell is on indirect path, i.e. MP configuration is not present. Otherwise the field is absent.
Up

 –  SL-MeasConfigCommonp. 1351

The IE SL-MeasConfigCommon is used to set the cell specific SL RSRP measurement configurations for unicast destinations.
SL-MeasConfigCommon information element
SL-MeasConfigCommon field descriptions
sl-MeasIdListCommon
List of sidelink measurement identities
sl-MeasObjectListCommon
List of sidelink measurement objects.
sl-QuantityConfigCommon
Indicates the layer 3 filtering coefficient for sidelink measurement.
sl-ReportConfigListCommon
List of sidelink measurement reporting configurations.
Up

 –  SL-MeasConfigInfop. 1352

The IE SL-MeasConfigInfo is used to set RSRP measurement configurations for unicast destinations.
SL-MeasConfigInfo information element
SL-MeasConfigInfo field descriptions
sl-MeasIdToAddModList
List of sidelink measurement identities to add and/or modify.
sl-MeasIdToRemoveList
List of sidelink measurement identities to remove.
sl-MeasObjectToAddModList
List of sidelink measurement objects to add and/or modify.
sl-MeasObjectToRemoveList
List of sidelink measurement objects to remove.
sl-QuantityConfig
Indicates the layer 3 filtering coefficient for sidelink measurement.
sl-ReportConfigToAddModList
List of sidelink measurement reporting configurations to add and/or modify.
sl-ReportConfigToRemoveList
List of sidelink measurement reporting configurations to remove.
Up

 –  SL-MeasIdListp. 1353

The IE SL-MeasIdList concerns a list of SL measurement identities to add or modify for a destination, with for each entry the sl-MeasId, the associated sl-MeasObjectId and the associated sl-ReportConfigId.
SL-MeasIdList information element
Up

 –  SL-MeasObjectListp. 1353

The IE SL-MeasObjectList concerns a list of SL measurement objects to add or modify for a destination.
SL-MeasObjectList information element
SL-MeasObjectList field descriptions
frequencyInfoSL
It indicates the lowest usable subcarrier on the carrier where SL RSRP is measured, determined according to sl-AbsoluteFrequencyPointA in IE SL-FreqConfig/SL-FreqConfigCommon and offsetToCarrier in IE SCS-SpecificCarrier configured for sl-SCS-SpecificCarrierList in IE SL-FreqConfig/SL-FreqConfigCommon. See clause 8.2.5 of TS 38.211.
sl-MeasObjectId
It is used to identify a sidelink measurement object configuration.
sl-MeasObject
It specifies information applicable for sidelink DMRS measurement.
Up

 –  SL-PagingIdentityRemoteUEp. 1354

The IE SL-PagingIdentityRemoteUE includes the Remote UE's paging UE ID.
SL-PagingIdentityRemoteUE information element
Up

 –  SL-PBPS-CPS-Configp. 1355

The IE SL-PBPS-CPS-Config specifies the operation information for a resource pool which can be (pre-)configured to enable full sensing only, partial sensing only, random resource selection only, or any combination(s) thereof.
SL-PBPS-CPS-Config information element
SL-PBPS-CPS-Config field descriptions
sl-Additional-PBPS-Occasion
Indicates that UE additionally monitors periodic sensing occasions that correspond to a set of values. (see clause 8.1.4 of TS 38.214).
sl-AllowedResourceSelectionConfig
Indicates the allowed resource selection mechanism(s), i.e. full sensing only, partial sensing only, random resource selection only, or any combination(s) thereof. (see clause 8.1.4 of TS 38.214). Only c1, c4 , c5 or c7 can be configured for a Rel-16 resource pool. If this field is not configured for a resource pool included in sl-TxPoolSelectedNormal, only full sensing is allowed in the corresponding resource pool.
c1: only full sensing allowed
c2: only partial sensing allowed
c3: only random selection allowed
c4: full sensing+random selection allowed
c5: full sensing+ partial sensing allowed
c6: partial sensing + random selection allowed
c7: full sensing+ partial sensing + random selection allowed.
sl-CPS-WindowAperiodic
Parameter that indicates the minimum size of contiguous partial sensing window in logical slot units for a resource (re)selection procedure and re-evaluation/pre-emption checking triggered by aperiodic transmission. (see clause 8.1.4 of TS 38.214). If not configured, the size of contiguous partial sensing window in logical slot units is 31.
sl-CPS-WindowPeriodic
Indicates the size of contiguous partial sensing window in logical slot units when UE performs periodic-based and contiguous partial sensing for a resource (re)selection procedure triggered by periodic transmission. If not configured, the size of contiguous partial sensing window in logical slot units is 31.
sl-DefaultCBR-PartialSensing
Indicates default value of SL CBR measurement for a UE that is configured to perform partial sensing by its higher layer (including when SL DRX is configured) if the number of SL RSSI measurement slots over CBR measurement window is below sl-MinNumRssiMeasurementSlots, (see clause 8.1.6 of TS 38.214). Value 0 corresponds to 0, value 1 to 0.01, value 2 to 0.02, and so on.
sl-DefaultCBR-RandomSelection
Indicates default value of CBR measurement for a UE that performs random resource selection if no SL CBR measurement result over SL CBR measurement window, (see clause 8.1.6 of TS 38.214). Value 0 corresponds to 0, value 1 to 0.01, value 2 to 0.02, and so on.
sl-MinNumCandidateSlotsAperiodic
Indicates the minimum number of Y' slots that are included in the possible candidate resources corresponding to periodic-based partial sensing and/or contiguous partial sensing for resource (re)selection triggered by aperiodic transmission. (see clause 8.1.4 of TS 38.214).
sl-MinNumCandidateSlotsPeriodic
Indicates the minimum number of Y slots that are included in the possible candidate resources corresponding to periodic-based partial sensing for resource (re)selection triggered by periodic transmission. (see clause 8.1.4 of TS 38.214).
sl-MinNumRssiMeasurementSlots
Indicates a threshold for a minimum number of SL RSSI measurement slots over CBR measurement window for which the SL RSSI is measured for a UE that is configured to perform partial sensing by its higher layer (including when SL DRX is configured). (see clause 8.1.6 of TS 38.214).
sl-PartialSensingInactiveTime
Indicates whether or not UE is required to perform SL reception of PSCCH and RSRP measurement for partial sensing on slots in SL DRX inactive time when partial sensing is configured by its higher layer. (see clause 8.1.4 of TS 38.214).
sl-PBPS-OccasionReservePeriodList
Indicates the subset of periodicity values from sl-ResourceReservePeriodList used to determine periodic sensing occasions in periodic-based partial sensing, by means of an index to the corresponding entry in sl-ResourceReservePeriodList-r16. If not configured, all periodicity values from sl-ResourceReservePeriodList are used to determine periodic sensing occasions in periodic-based partial sensing (see clause 8.1.4 of TS 38.214).
Up

 –  SL-PDCP-Configp. 1357

The IE SL-PDCP-Config is used to set the configurable PDCP parameters for a sidelink radio bearer.
SL-PDCP-Config information element
SL-PDCP-Config field descriptions
sl-DiscardTimer
Value in ms of discardTimer specified in TS 38.323. Value ms50 corresponds to 50 ms, value ms100 corresponds to 100 ms and so on.
sl-OutOfOrderDelivery
Indicates whether or not outOfOrderDelivery specified in TS 38.323 is configured. This field should be either always present or always absent, after the radio bearer is established.
sl-PDCP-SN-Size
PDCP sequence number size for unicast NR sidelink communication, 12 or 18 bits, as specified in TS 38.323. For groupcast and broadcast NR sidelink communication, only 12 bits is applicable, as specified in clause 9.1.1.5.
Conditional Presence Explanation
SetupThe field is mandatory present in case of sidelink DRB setup via dedicated signaling and in case of sidelink DRB configuration via system information and pre-configuration; otherwise the field is optionally present, need M.
Setup2The field is mandatory present in case of sidelink DRB setup via dedicated signaling and in case of sidelink DRB configuration via system information and pre-configuration for RLC-AM and RLC-UM for unicast NR sidelink communication; otherwise the field is not present, Need M.
Up

 –  SL-PRS-ResourcePoolp. 1357

The IE SL-PRS-ResourcePool specifies the configuration information for NR sidelink PRS dedicated resource pool.
SL-PRS-ResourcePool information element
SL-PRS-ResourcePool field descriptions
sl-RB-Number
Indicates the number of PRBs in the corresponding SL PRS dedicated resource pool, which consists of contiguous PRBs only.
sl-StartRB-Subchannel-DedicatedSL-PRS-RP
Indicates the lowest RB index of the SL PRS dedicated resource pool with respect to the lowest RB index of a SL BWP.
sl-TimeResource
This field indicates the bitmap of the SL PRS dedicated resource pool, which is defined by repeating the bitmap with a periodicity during a SFN or DFN cycle.
sl-PosAllowedResourceSelectionConfig
Indicates allowed resource allocation method configured per resource pool.
C1: only sensing allowed
c2: only random resource selection allowed
c3: sensing and random resource selection allowed
sl-PRS-ResourceReservePeriodList
Indicates set of possible resource reservation period in the unit of ms allowed in the resource pool. Up to 16 values can be configured per resource pool. The possible resource reservation period are periodicities for legacy SL communication and the ones defined for DL-PRS.
sl-PRS-ResourcesDedicatedSL-PRS-RP
Indicates SL PRS resources in a slot of dedicated SL PRS resource pool as defined in TS 38.211.
sl-SensingWindowDedicated-SL-PRS-RP
Indicates Parameter that indicates the start of the sensing window for SL PRS in a dedicated resource pool.
sl-TxPercentageDedicatedSL-PRS-RP-List
Indicates List of minimum Tx percentage (list per priority)
sl-SCI-basedSL-PRS-TxTriggerSCI1-B
Indicates presence of a bit-field in SCI format 1-B to trigger SL-PRS transmission by a receiving UE.
sl-NumSubchannelDedicatedSL-PRS-RP
Indicates the number of subchannels in the corresponding resource pool, which consists of contiguous PRBs only.
sl-SubchannelSizeDedicatedSL-PRS-RP
Indicates size of a subchannel for PSCCH in number of RBs.
sl-MaxNumPerReserveDedicatedSL-PRS-RP
Indicates the maximum number of SL PRS reservations that can be indicated by an SCI.
sl-NumReservedBitsSCI1B-DedicatedSL-PRS-RP
Indicates the number of reserved bits in SCI format 1-B.
sl-SRC-ID-LenDedicatedSL-PRS-RP
Indicates the number of bits used for the source ID in SCI format 1-B.
sl-CBR-PriorityTxConfigList-DedicatedSL-PRS-RP
Indicates the mapping between SL-PRS transmission parameter (such as transmission power, etc.) sets by using the indexes of the configurations in sl-CBR-SL-PRS-TxConfigList, CBR ranges by using the indexes to the entry of the CBR range configurations in sl-CBR-SL-PRS-RangeConfigList, and priority ranges. It also indicates the default SL-PRS transmission parameters to be used when CBR measurement results are not available.
sl-PriorityThresholdDedicatedSL-PRS-RP
Indicates the upper bound of priority range which is associated with the configurations in sl-CBR-ConfigIndex-Dedicated-SL-PRS-RP and in sl-PRS-Tx-ConfigIndex. The upper bounds of the priority ranges are configured in ascending order for consecutive entries of SL-PriorityTxConfigIndex-Dedicated-SL-PRS-RP in SL-PriorityTxConfigList-Dedicated-SL-PRS-RP. For the first entry of sl-PriorityThreshold-Dedicated-SL-PRS-RP, the lower bound of the priority range is 1.
sl-TimeWindowSizeCBR-DedicatedSL-PRS-RP
Indicates the time window size for CBR measurement in a dedicated SL-PRS resource pool.
sl-TimeWindowSizeCR-DedicatedSL-PRS-RP
Indicates the time window size for CR evaluation in a dedicated SL-PRS resource pool.
sl-DefaultTxConfigIndexDedicatedSL-PRS-RP
Indicates the SL PRS transmission parameters to be used by the UEs which do not have available CBR measurement results, by means of an index to the corresponding entry in sl-PRS-TxConfigIndexList. Value 0 indicates the first entry in sl-PRS-Tx-ConfigIndexList. The field is ignored if the UE has available CBR measurement results.
sl-CBR-ConfigIndexDedicatedSL-PRS-RP
Indicates the CBR ranges to be used by an index to the entry of the CBR range configuration in sl-CBR-RangeConfigList-Dedicated-SL-PRS-RP.
sl-PRS-TxConfigIndexList
Indicates List of sl-PRS-Tx-ConfigIndex indicating the SL PRS transmission index
sl-PRS-TxConfigIndex
Indicates SL PRS transmission Configuration index.
sl-PriorityThreshold
Indicates the threshold used to determine whether NR sidelink transmission in dedicated SL PRS resource pool is prioritized over uplink transmission of priority index 0 as specified in clause 16.2.4.3 of TS 38.213, or whether PUCCH transmission carrying SL HARQ is prioritized over PUCCH transmission carrying UCI of priority index 0 if they overlap in time as specified in clause 9.2.5.0 of TS 38.213.
sl-PriorityThresholdUL-URLLC
Indicates the threshold used to determine whether NR sidelink transmission in dedicated SL PRS resource pool is prioritized over uplink transmission of priority index 1 as specified in clause 16.2.4.3 of TS 38.213, or whether PUCCH transmission carrying SL HARQ is prioritized over PUCCH transmission carrying UCI of priority index 1 if they overlap in time as specified in clause 9.2.5.0 of TS 38.213.
SL-PRS-PSCCH-Config field descriptions
freqResourcePSCCH-Dedicated-SL-PRS-RP
Indicates the number of PRBs for PSCCH in a dedicated SL PRS resource pool.
timeResourcePSCCH-Dedicated-SL-PRS-RP
Indicates the number of symbols for PSCCH in a dedicated SL PRS resource pool.
SL-PRS-PowerControl field descriptions
dl-P0-SL-PRS
Indicates P0 value for DL pathloss based open loop power control for SL PRS transmission in dedicated SL PRS resource pool.
dl-AlphaSL-PRS
Indicates alpha value for DL pathloss based open loop power control for SL PRS transmission in dedicated SL PRS resource pool.
sl-P0-SL-PRS
Indicates P0 value for SL pathloss based open loop power control for SL PRS transmission in dedicated SL PRS resource pool.
sl-AlphaSL-PRS
Indicates alpha value for downlink pathloss based power control for PSCCH/PSSCH when dl-P0-PSSCH-PSCCH is configured. When the field is absent the UE applies the value 1.
Up

 –  SL-PSBCH-Configp. 1357

The IE SL-PSBCH-Config indicates PSBCH transmission parameters on each sidelink bandwidth part.
SL-PSBCH-Config information element
SL-PSBCH-Config field descriptions
dl-Alpha-PSBCH
Indicates alpha value for DL pathloss based power control for PSBCH. When the field is not configured the UE applies the value 1.
dl-P0-PSBCH
Indicates P0 value for DL pathloss based power control for PSBCH. If not configured, DL pathloss based power control is disabled for PSBCH. When dl-P0-PSBCH-r17 is configured, the UE ignores dl-P0-PSBCH-r16. A Remote UE which is out of coverage, considers downlink pathloss based power control is disabled for PSBCH when dl-P0-PSBCH is configured.
Up

 –  SL-PSSCH-TxConfigListp. 1362

The IE SL-PSSCH-TxConfigList indicates PSSCH transmission parameters. When lower layers select parameters from the range indicated in IE SL-PSSCH-TxConfigList, the UE considers both configurations in IE SL-PSSCH-TxConfigList and the CBR-dependent configurations represented in IE SL-CBR-PriorityTxConfigList. Only one IE SL-PSSCH-TxConfig is provided per SL-TypeTxSync.
SL-PSSCH-TxConfigList information element
SL-PSSCH-TxConfigList field descriptions
sl-MaxTxTransNumPSSCH
Indicates the maximum transmission number (including new transmission and retransmission) for PSSCH.
sl-MaxTxPower
This field indicates the maximum transmission power for transmission on PSSCH and PSCCH.
sl-MinMCS-PSSCH, sl-MaxMCS-PSSCH
This field indicates the minimum and maximum MCS values used for transmissions on PSSCH. The UE shall ignore the minimum and maximum MCS values used for the associated MCS table(s) in sl-ParametersAboveThres-r16 and sl-ParametersBelowThres-r16 if sl-ParametersAboveThres-v1650 and sl-ParametersBelowThres-v1650 are present, respectively.
sl-MinSubChannelNumPSSCH, sl-MaxSubChannelNumPSSCH
This field indicates the minimum and maximum number of sub-channels which may be used for transmissions on PSSCH.
sl-TypeTxSync
This field indicates the synchronization reference type. For configurations by the eNB/gNB, only gnbEnb can be configured; and for pre-configuration or when this field is absent, the configuration is applicable for all synchronization reference types.
sl-ThresUE-Speed
This field indicates a UE absolute speed threshold.
Conditional Presence Explanation
CBRThe field is optionally present, Need R, when the IE SL-PSSCH-TxParameters is present in SL-CBR-CommonTxConfigList, SL-UE-SelectedConfig, SIB12 or SidelinkPreconfigNR; otherwise the field is not present, need R.
Up

 –  SL-QoS-FlowIdentityp. 1363

The IE SL-QoS-FlowIdentity is used to identify a sidelink QoS flow.
SL-QoS-FlowIdentity information element

 –  SL-QoS-Profilep. 1363

The IE SL-QoS-Profile is used to give the QoS parameters for a sidelink QoS flow. Need codes or conditions specified for SL-QoS-Profile do not apply, in case SL-QoS-Profile is included in SidelinkUEInformationNR.
SL-QoS-Profile information element
SL-QoS-Profile field descriptions
sl-GFBR
Indicate the guaranteed bit rate for a GBR QoS flow. The unit is: Kbit/s
sl-MFBR
Indicate the maximum bit rate for a GBR QoS flow. The unit is: Kbit/s
sl-PQI
This field indicates either the PQI for standardized PQI or non-standardized QoS parameters.
sl-Range
This field indicates the range parameter of the Qos flow, as defined in clause 5.4.1.1.1 of TS 23.287. It is present only for groupcast. The unit is meter.
SL-PQI field descriptions
sl-AveragingWindow
Indicates the Averaging Window for a QoS flow, and applies to GBR QoS flows only. Unit: ms. The default value of the IE is 2000ms.
sl-MaxDataBurstVolume
Indicates the Maximum Data Burst Volume for a QoS flow, and applies to delay critical GBR QoS flows only. Unit: byte.
sl-PacketDelayBudget
Indicates the Packet Delay Budget for a QoS flow. Upper bound value for the delay that a packet may experience expressed in unit of 0.5ms.
sl-PacketErrorRate
Indicates the Packet Error Rate for a QoS flow. The packet error rate is expressed as Scalar x 10-k where k is the Exponent.
sl-PriorityLevel
Indicates the Priority Level for a QoS flow. Values ordered in decreasing order of priority, i.e. with 1 as the highest priority and 8 as the lowest priority.
sl-StandardizedPQI
Indicate the PQI for standardized PQI.
Up

 –  SL-QuantityConfigp. 1365

The IE SL-QuantityConfig specifies the layer 3 filtering coefficients for NR SL RSRP measurement for a destination.
SL-QuantityConfig information element
SL-QuantityConfig field descriptions
sl-FilterCoefficientDMRS
DMRS based L3 filter configuration:
Specifies L3 filter configuration for sidelink RSRP measurement result from the L1 fiter(s), as defined in TS 38.215.
Up

 –  SL-RadioBearerConfigp. 1365

The IE SL-RadioBearerConfig specifies the sidelink DRB configuration information for NR sidelink communication.
SL-RadioBearerConfig information element
SL-RadioBearerConfig field descriptions
sl-PDCP-Config
This field indicates the PDCP parameters for the sidelink DRB.
sl-SDAP-Config
This field indicates how to map sidelink QoS flows to sidelink DRB.
slrb-Uu-ConfigIndex
This field indicates the index of sidelink DRB configuration.
sl-TransRange
This field indicates the transmission range of the sidelink DRB. The unit is meter.
Conditional Presence Explanation
SLRBSetupThe field is mandatory present in case of sidelink DRB setup via the dedicated signalling and in case of sidelink DRB configuration via system information and pre-configuration; otherwise the field is optionally present, need M.
Up

 –  SL-RBSetConfigp. 1366

The IE SL-RBSetConfig specifies the configuration information for RB set for NR Sidelink Communication.
SL-RBSetConfig information element
SL-RBSetConfig field descriptions
sl-GapBetweenSSSBRepetition
Indicates the gap between two adjacent S-SSB repetitions in frequency domain in one RB set, and the gap is between the lowest subcarrier of the upper PSBCH and the highest subcarrier of the lower PSBCH. The Unit is PRB.
sl-NumOfSSSBRepetition
Indicates the number of S-SSB repetitions in frequency domain in one RB set. Legacy S-SSB are applicable in region with no OCB requirement, or with OCB exemption.
sl-RBSetIndex
Indicates the index of RB-set for which the configuration applies.
Up

 –  SL-RelayUE-Configp. 1367

The IE SL-RelayUE-Config specifies the configuration information for NR sidelink U2N Relay UE.
SL-RelayUE-Config information element
SL-RelayUE-Config field descriptions
threshHighRelay
Indicates the upper threshold of Uu RSRP for a UE that is in network coverage to evaluate AS layer conditions for U2N relay UE operation.
threshLowRelay
Indicates the lower threshold of Uu RSRP for a UE that is in network coverage to evaluate AS layer conditions for U2N relay UE operation.
Conditional Presence Explanation
ThreshHighRelayThis field is mandatory present if threshHighRelay is included. Otherwise, the field is absent, Need R.
ThreshLowRelayThis field is mandatory present if threshLowRelay is included. Otherwise, the field is absent, Need R.
Up

 –  SL-RelayUE-ConfigU2Up. 1368

The IE SL-RelayUE-ConfigU2U specifies the threshold configuration information for NR sidelink U2U Relay UE.
SL-RelayUE-ConfigU2U information element
SL-RelayUE-ConfigU2U field descriptions
sl-RSRP-Thresh-DiscConfig
Indicates the threshold of SL-RSRP for a U2U Relay UE to evaluate AS layer conditions for discovery. The U2U relay UE applies the value of this field to decide which UE(s) can be announced as proximity UE(s) in the discovery message when performing U2U Relay Discovery with Model A, and decide whether to forward the discovery message when performing the U2U Relay Discovery with Model B as specified in [65].
sd-RSRP-Thresh-DiscConfig
Indicates the threshold of SD-RSRP for a U2U Relay UE to evaluate AS layer conditions for discovery. The U2U relay UE applies the value of this field to evaluate AS layer conditions to decide which UE(s) can be announced as proximity UE(s) in the discovery message when performing U2U Relay Discovery with Model A, and decide whether to forward the discovery message when performing the U2U Relay Discovery with Model B or U2U relay communication with integrated Discovery as specified in TS 23.304.
Conditional Presence Explanation
SL-RSRP-ThreshRelayThis field is mandatory present if sl-RSRP-Thresh-DiscConfig is included. Otherwise, the field is absent, Need R.
SD-RSRP-ThreshRelayThis field is mandatory present if sd-RSRP-Thresh-DiscConfig is included. Otherwise, the field is absent, Need R.
Up

 –  SL-RemoteUE-Configp. 1368

The IE SL-RemoteUE-Config specifies the configuration information for NR sidelink U2N Remote UE.
SL-RemoteUE-Config information element
SL-RemoteUE-Config field descriptions
sl-ReselectionConfig
Includes the parameters used by the U2N remote UE when selecting/ reselecting a U2N relay UE.
thresHighRemote
Indicates the threshold of Uu RSRP for a UE that is in network coverage to evaluate AS layer conditions for U2N remote UE operation.
SL-ReselectionConfig field descriptions
sl-FilterCoefficientRSRP
Specifies L3 filter coefficient for SL communication/ discovery RSRP measurement results from L1 filter.
sl-RSRP-Thresh
Indicates the threshold of SL communication/ discovery RSRP for a U2N remote UE to perform relay UE selection/ reselection.
Conditional Presence Explanation
SL-RSRP-ThreshThis field is mandatory present if sl-RSRP-Thresh is included. Otherwise, the field is absent, Need R.
ThreshHighRemoteThis field is mandatory present if threshHighRemote is included. Otherwise, the field is absent, Need R.
Up

 –  SL-RemoteUE-ConfigU2Up. 1369

The IE SL-RemoteUE-ConfigU2U specifies the threshold configuration information for NR sidelink U2U Remote UE.
SL-RemoteUE-ConfigU2U information element
SL-RemoteUE-ConfigU2U field descriptions
sl-RSRP-ThreshU2U
Indicates the threshold of SL-RSRP for a U2U Remote UE to perform Relay UE selection/ reselection. The U2U remote UE applies the value of this field to evaluate AS layer conditions on direct PC5 link with the peer U2U Remote UE to trigger relay selection, and evaluate AS layer conditions on U2U relay link with U2U Relay UE to trigger relay reselection.
sl-FilterCoefficientU2U
Specifies L3 filter coefficient for SL-RSRP measurement results from L1 filter.
sd-RSRP-ThreshU2U
Indicates the threshold of SD-RSRP for a U2U Remote UE to perform discovery and Relay UE selection/ reselection. For discovery, the U2U Remote UE applies the value of this field to evaluate AS layer conditions to decide whether to respond the discovery message when performing the U2U Relay Discovery with Model B as specified in TS 23.304. For relay selection and reselection, the U2U remote UE applies the value of this field to evaluate AS layer conditions on direct PC5 link to trigger relay selection, and evaluate AS layer conditions on U2U relay link to trigger relay reselection. The target U2U remote UE applies the value of this field to evaluate AS layer conditions trigger relay selection when performing U2U relay communication with integrated Discovery as specified in TS 23.304.
sd-FilterCoefficientU2U
Specifies L3 filter coefficient for SD-RSRP measurement results from L1 filter.
Conditional Presence Explanation
SL-RSRP-ThreshU2UThis field is mandatory present if sl-RSRP-ThreshU2U is included. Otherwise, the field is absent, Need R.
SD-RSRP-ThreshU2UThis field is mandatory present if sd-RSRP-ThreshU2U is included. Otherwise, the field is absent, Need R.
Up

 –  SL-ReportConfigListp. 1370

The IE SL-ReportConfigList concerns a list of SL measurement reporting configurations to add or modify for a destination.
SL-ReportConfigList information element
SL-ReportConfig field descriptions
sl-ReportType
Type of the configured sidelink measurement report.
SL-EventTriggerConfig field descriptions
sl-EventId
Choice of sidelink measurement event triggered reporting criteria.
sl-ReportAmount
Number of sidelink measurement reports applicable for sl-EventTriggered report type.
sl-ReportInterval
Indicates the interval between periodical reports (i.e., when sl-ReportAmount exceeds 1) for sl-EventTriggered report type.
sl-ReportOnLeave
indicates whether or not the UE shall initiate the sidelink measurement reporting procedure when the leaving condition is met for a frequency in sl-FrequencyTriggeredList, as specified in clause 5.8.10.4.1.
sl-ReportQuantity
The sidelink measurement quantities to be included in the sidelink measurement report.
sl-TimeToTrigger
Time during which specific criteria for the event needs to be met in order to trigger a sidelink measurement report.
sN-Threshold
Threshold used for events S1 and S2 specified in clauses 5.8.10.4.2 and 5.8.10.4.3, respectively.
SL-PeriodicalReportConfig field descriptions
sl-ReportAmount
Number of sidelink measurement reports applicable for sl-Periodical report type.
sl-ReportInterval
Indicates the interval between periodical reports (i.e., when sl-ReportAmount exceeds 1) for sl-Periodical report type.
sl-ReportQuantity
The sidelink measurement quantities to be included in the sidelink measurement report.
Up

 –  SL-ResourcePoolp. 1372

The IE SL-ResourcePool specifies the configuration information for NR sidelink communication resource pool.
SL-ResourcePool information element
SL-ZoneConfigMCR field descriptions
sl-TransRange
Indicates the communication range requirement for the corresponding sl-ZoneConfigMCR-Index. The unit is meter.
sl-ZoneConfig
Indicates the zone configuration for the corresponding sl-ZoneConfigMCR-Index.
sl-ZoneConfigMCR-Index
Indicates the codepoint of the communication range requirement field in SCI.
SL-ResourcePool field descriptions
dummy
This field is not used in the specification. If received it shall be ignored by the UE.
numSym-SL-PRS-2ndStageSCI
Indicates the number symbols to be assumed for SL PRS in determining the number of coded modulation symbols for second stage SCI in a slot of a shared SL PRS resource pool.
sl-A2X-Service
Presence of this field indicates the resource pool is dedicated for A2X service, i.e., not to be used for other than A2X service. Value brid indicates the resource pool is for BRID, value daa indicates the resource pool is for DAA, and value bridAndDAA indicates the resource poos is for both BRID and DAA. If this field is absent in all the configured resource pools, the UE may choose non-dedidcated resource pool for A2X service.
sl-Additional-MCS-Table
Indicates the MCS table(s) additionally used in the resource pool. 64QAM table is (pre-)configured as default. Zero, one or two can be additionally (pre-)configured using the 256QAM and/or low-SE MCS tables. If two MCS tables are indicated, 256QAM MCS table is the 1st table and qam64lowSE MCS table is the 2nd table as specified in clause 8.1.3.1 of TS 38.214.
sl-CPE-StartingPositionsPSCCH-PSSCH-InitiateCOT-Default
Indicates CPE starting position index for the default CPE starting position, to be used for PSCCH/PSSCH transmission when UE initiating a COT.
sl-CPE-StartingPositionsPSCCH-PSSCH-InitiateCOT-List
Indicates a set of selected indices that correspond to multiple candidate CPE starting positions to be used for PSCCH/PSSCH transmission when UE initiating a COT, associated per L1 priority of PSSCH.
sl-CPE-StartingPositionsPSCCH-PSSCH-WithinCOT-Default
Indicates CPE starting position index for the default CPE starting position, to be used by UE for PSCCH/PSSCH transmission within a COT.
sl-CPE-StartingPositionsPSCCH-PSSCH-WithinCOT-List
Indicates a set of one or multiple selected indices that correspond to one or multiple candidate CPE starting positions to be used by UE for PSCCH/PSSCH transmission within a COT, associated per L1 priority of PSSCH.
sl-CPE-StartingPositionPSFCH
Indicates CPE starting position within the GP symbol before PSFCH transmission. The value is an index of the set of all candidate CPE starting positions specified in Table 5.3.1-3 of TS 38.211 for Ci=1 and the corresponding SCS of the SL BWP.
sl-FilterCoefficient
This field indicates the filtering coefficient for long-term measurement and reference signal power derivation used for sidelink open-loop power control.
sl-InterUE-CoordinationConfig
Indicates the configured sidelink inter-UE coordination parameters.
sl-IUC-RB-SetList
The n-th value in the list indicates the set of PRBs that are actually used for inter-UE coordination information transmission and reception in Scheme 2. It shall be (pre-)configured such that N candidate PSFCH occasion(s) are associated with N different PRB sets. PRBs within intra-cell guard band are not used for PSFCH transmission. The length of this list is aligned with sl-NumPSFCH-Occasions. For each PSFCH occasion, the set of PRBs are indicated in the same format as in sl-PSFCH-RB-Set.
sl-NumDedicatedPRBs-ForPSFCH
Indicates the value of K3 when each PSFCH transmission occupies "1 common interlace and K3 dedicated PRB(s)" (as indicated by sl-TransmissionStructureForPSFCH). Value prb1 corresponds to K3=1, value prb2 corresponds to K3=2, and so on. UE expects the same (pre-)configured value of sl-NumDedicatedPRBs-ForPSFCH across all resource pools.
sl-NumInterlacePerSubchannel
Indicates the number of (K) interlaces per sub-channel within a resource pool. Value sc1 corresponds to 1 interlace per sub-channel, and value sc2 corresponds to 2 interlaces per sub-channel. The applicable values are related to the subcarrier spacing as below:
For SCS = 15 kHz: K=1 or 2
For SCS = 30 kHz: K=1
sl-NumPSFCH-Occasions
Indicates one PSCCH/PSSCH transmission has N associated candidate PSFCH occasion(s). Value o1 corresponds to N=1, value o2 corresponds to N=2, and so on. If the field is not configured, the UE shall use value o1.
sl-NumReferencePRBs-OfInterlace
Indicate reference number of PRBs of one interlace within 1 RB set. Value prb10 corresponds to 10 PRBs, and value prb11 corresponds to 11 PRBs.
sl-NumRefSymbolLength
Indicates a reference number of symbols for TBS determination.
sl-NumSubchannel
Indicates the number of subchannels in the corresponding resource pool, which consists of contiguous PRBs only.
sl-PBPS-CPS-Config
Indicates the allowed resource allocation schemes of full sensing only, partial sensing only, random resource selection only, or any combination(s), and the related configuration for power saving resource allocation schemes. This field is absent for sl-TxPoolExceptional.
sl-PreemptionEnable
Indicates whether pre-emption is disabled or enabled in a resource pool. If the field is present and the value is pl1, pl2, and so on (but not enabled), it means that pre-emption is enabled and a priority level p_preemption is configured. If the field is present and the value is enabled, the pre-emption is enabled (but p_preemption is not configured) and pre-emption is applicable to all levels.
sl-PriorityThreshold-UL-URLLC
Indicates the threshold used to determine whether NR sidelink transmission is prioritized over uplink transmission of priority index 1 as specified in clause 16.2.4.3 of TS 38.213, or whether PUCCH transmission carrying SL HARQ is prioritized over PUCCH transmission carrying UCI of priority index 1 if they overlap in time as specified in clause 9.2.5.0 of TS 38.213.
sl-PriorityThreshold
Indicates the threshold used to determine whether NR sidelink transmission is prioritized over uplink transmission of priority index 0 as specified in clause 16.2.4.3 of TS 38.213, or whether PUCCH transmission carrying SL HARQ is prioritized over PUCCH transmission carrying UCI of priority index 0 if they overlap in time as specified in clause 9.2.5.0 of TS 38.213.
sl-PRS-ResourcesSharedSL-PRS-RP
Indicates SL PRS resources in a slot of shared SL PRS resource pool as defined in TS 38.211.
sl-PSFCH-CommonInterlaceIndex
Indicate the index of common interlace to meet OCB requirements when transmissionStructureForPSFCH is set to common interlace. Value 0 corresponds to interlace 0 is used as common interlace, value 1 corresponds to interlace 1 is used as common interlace and so on.
sl-PSFCH-PowerOffset
Indicates the power offset between Tx power on one common PRB (P_common) and Tx power on one dedicated PRB (P_dedicated) when sl-TransmissionStructureForPSFCH is (pre-)configured as commonInterlace, i.e., P_common = P_dedicated - offset. UE expects the same (pre-)configured value of sl-PSFCH-PowerOffset across all resource pools. The unit is dB.
sl-PSFCH-RB-SetList
The n-th value in the list indicates the set of PRBs that are actually used for PSFCH transmission and reception of n-th PSFCH occasion of a PSCCH/PSSCH transmission.
It shall be (pre-)configured such that N candidate PSFCH occasion(s) are associated with N different PRB sets. PRBs within intra-cell guard band are not used for PSFCH transmission. The length of this list is aligned with sl-NumPSFCH-Occasions. For each PSFCH occasion, the set of PRBs are indicated in the same format as in sl-PSFCH-RB-Set.
sl-RB-Number
Indicates the number of PRBs in the corresponding resource pool, which consists of contiguous PRBs only. The remaining RB cannot be used (See clause 8 of TS 38.214).
sl-RBSetIndexOfResourcePool
For interlace RB based PSCCH/PSSCH, indicates the RB set index(s) included in the resource pool. Contiguous RB sets are (pre-)configured for a resource pool.
sl-SCI-based-SL-PRS-Tx-Trigger-SCI2-D
Indicates presence of a bit-field in SCI format 2-D to trigger SL-PRS transmission by a receiving UE.
sl-StartRB-Subchannel
Indicates the lowest RB index of the subchannel with the lowest index in the resource pool with respect to the lowest RB index of a SL BWP.
sl-SubchannelSize
Indicates the minimum granularity in frequency domain for the sensing for PSSCH resource selection in the unit of PRB.
sl-SyncAllowed
Indicates the allowed synchronization reference(s) which is (are) allowed to use the configured resource pool.
sl-SyncConfigIndex
Indicates the synchronisation configuration that is associated with a reception pool, by means of an index to the corresponding entry SL-SyncConfigList of in SIB12 for NR sidelink communication.
sl-TDD-Configuration
Indicates the TDD configuration associated with the reception pool of the cell indicated by sl-SyncConfigIndex.
sl-ThreshS-RSSI-CBR
Indicates the S-RSSI threshold for determining the contribution of a sub-channel to the CBR measurement. Value 0 corresponds to -112 dBm, value 1 to -110 dBm, value n to (-112 + n*2) dBm, and so on.
sl-TimeResource
Indicates the bitmap of the resource pool, which is defined by repeating the bitmap with a periodicity during a SFN or DFN cycle.
sl-TimeWindowSizeCBR
Indicates the time window size for CBR measurement.
sl-TimeWindowSizeCR
Indicates the time window size for CR evaluation.
sl-TransmissionStructureForPSFCH
Indicate each PSFCH transmission occupies "1 common interlace and K3 dedicated PRB(s)", or "1 dedicated interlace". Value commonInterlace corresponds to "1 common interlace and K3 dedicated PRB(s)", and value dedicatedInterlace corresponds to "1 dedicated interlace". UE expects the same (pre-)configured value of transmissionStructureForPSFCH across all resource pools.
sl-TxPercentageList
Indicates the portion of candidate single-slot PSSCH resources over the total resources. Value p20 corresponds to 20%, and so on.
sl-Type1-LBT-BlockingOption1
Indicates UE may avoid selection of N consecutive resource(s) before a reserved resource when the L1 SL priority value for the transmission is higher than the L1 SL priority value of the reserved resource, and UE may also avoid selection of M consecutive resource(s) after a reserved resource when the transmitting symbols of the reserved resource overlap with LBT of the selected resource. The selection of the value N is up to UE implementation from {0, 1, 2}. M is determined based on UE implementation (at least including 0).
sl-Type1-LBT-BlockingOption2
Indicates UE may prioritize/select resource(s) in the slot(s) for transmission, if UE's transmission in slot(s) before a reserved resource is able to share its initiated COT to the reservation.
sl-X-Overhead
Accounts for overhead from CSI-RS, PT-RS. If the field is absent, the UE applies value n0 (see clause 5.1.3.2 of TS 38.214).
SL-SyncAllowed field descriptions
gnbEnb-Sync
If configured, the (pre-) configured resources can be used if the UE is directly or indirectly synchronized to eNB or gNB (i.e., synchronized to a reference UE which is directly synchronized to eNB or gNB).
gnss-Sync
If configured, the (pre-) configured resources can be used if the UE is directly or indirectly synchronized to GNSS (i.e., synchronized to a reference UE which is directly synchronized to GNSS).
ue-Sync
If configured, the (pre-) configured resources can be used if the UE is synchronized to a reference UE which is not synchronized to eNB, gNB and GNSS directly or indirectly.
SL-PSCCH-Config field descriptions
sl-FreqResourcePSCCH
Indicates the number of PRBs for PSCCH in a resource pool where it is not greater than the number PRBs of the subchannel.
sl-DMRS-ScrambleID
Indicates the initialization value for PSCCH DMRS scrambling.
sl-NumReservedBits
Indicates the number of reserved bits in first stage SCI.
sl-TimeResourcePSCCH
Indicates the number of symbols of PSCCH in a resource pool.
SL-PSSCH-Config field descriptions
sl-BetaOffsets2ndSCI
Indicates candidates of beta-offset values to determine the number of coded modulation symbols for second stage SCI. The value indicates the index of Table 9.3-2 of TS 38.213.
sl-PSSCH-DMRS-TimePatternList
Indicates the set of PSSCH DMRS time domain patterns in terms of PSSCH DMRS symbols in a slot that can be used in the resource pool.
sl-Scaling
Indicates a scaling factor to limit the number of resource elements assigned to the second stage SCI on PSSCH. Value f0p5 corresponds to 0.5, value f0p65 corresponds to 0.65, and so on.
SL-PSFCH-Config field descriptions
sl-MinTimeGapPSFCH
The minimum time gap between PSFCH and the associated PSSCH in the unit of slots.
sl-NumMuxCS-Pair
Indicates the number of cyclic shift pairs used for a PSFCH transmission that can be multiplexed in a PRB.
sl-PSFCH-CandidateResourceType
Indicates the number of PSFCH resources available for multiplexing HARQ-ACK information in a PSFCH transmission (see clause 16.3 of TS 38.213).
sl-PSFCH-HopID
Scrambling ID for sequence hopping of the PSFCH used in the resource pool.
sl-PSFCH-Period
Indicates the period of PSFCH resource in the unit of slots within this resource pool. If set to sl0, no resource for PSFCH, and HARQ feedback for all transmissions in the resource pool is disabled.
sl-PSFCH-RB-Set
Indicates the set of PRBs that are actually used for PSFCH transmission and reception. The leftmost bit of the bitmap refers to the lowest RB index in the resource pool, and so on. Value 0 in the bitmap indicates that the corresponding PRB is not used for PSFCH transmission and reception while value 1 indicates that the corresponding PRB is used for PSFCH transmission and reception (see TS 38.213).
SL-PTRS-Config field descriptions
sl-PTRS-FreqDensity
Presence and frequency density of SL PT-RS as a function of scheduled BW. If the field is not configured, the UE uses K_PT-RS = 2
sl-PTRS-TimeDensity
Presence and time density of SL PT-RS as a function of MCS. If the field is not configured, the UE uses L_PT-RS = 1
sl-PTRS-RE-Offset
Indicates the subcarrier offset for SL PT-RS . If the field is not configured, the UE applies the value offset00 (see clause 8.4.1.2.2 of TS 38.211).
SL-UE-SelectedConfigRP field descriptions
sl-CBR-PriorityTxConfigList
Indicates the mapping between PSSCH transmission parameter (such as MCS, PRB number, retransmission number, CR limit) sets by using the indexes of the configurations in sl-CBR-PSSCH-TxConfigList, CBR ranges by using the indexes to the entry of the CBR range configurations in sl-CBR-RangeConfigList, and priority ranges. It also indicates the default PSSCH transmission parameters to be used when CBR measurement results are not available, and MCS range for the MCS tables used in the resource pool. The field sl-CBR-PriorityTxConfigList-v1650 is present only when sl-CBR-PriorityTxConfigList-r16 is configured.
sl-MaxNumPerReserve
Indicates the maximum number of reserved PSCCH/PSSCH resources that can be indicated by an SCI.
sl-MultiReserveResource
Indicates if it is allowed to reserve a sidelink resource for an initial transmission of a TB by an SCI associated with a different TB, based on sensing and resource selection procedure.
sl-NRPSFCH-EUTRA-ThresRSRP-List
Indicates a list of 64 thresholds from which a threshold should be selected based on the priority in the decoded EUTRA SCI and the priority in the NR SCI to be transmitted. A NR SL resource is excluded if the corresponding PSFCH transmission occasions overlap with resources indicated or reserved by the decoded EUTRA SCI in time domain and EUTRA PSSCH RSRP in the associated data resource is above the threshold. If the field is present, the UE shall perform the dynamic co-channel coexistence of LTE sidelink and NR sidelink as specified in TS 38.214; otherwise it shall not perform it.
sl-NRPSSCH-EUTRA-ThresRSRP-List
Indicates a list of 64 thresholds, and a threshold should be selected based on the priority in the decoded EUTRA SCI and the priority in the NR SCI to be transmitted. A NR SL resource is excluded if it is indicated or reserved by the decoded EUTRA SCI and EUTRA PSSCH RSRP in the associated data resource is above the threshold.
sl-ResourceReservePeriodList
Set of possible resource reservation period allowed in the resource pool in the unit of ms. Up to 16 values can be configured per resource pool. The value ms0 is always configured.
sl-RS-ForSensing
Indicates whether DMRS of PSCCH or PSSCH is used for L1 RSRP measurement in the sensing operation.
sl-SensingWindow
Parameter that indicates the start of the sensing window.
sl-SelectionWindowList
Parameter that determines the end of the selection window in the resource selection for a TB with respect to priority indicated in SCI. Value n1 corresponds to 1*2μ, value n5 corresponds to 5*2μ, and so on, where μ = 0,1,2,3 refers to SCS 15,30,60,120 kHz respectively.
sl-Thres-RSRP-List
Indicates a list of 64 thresholds, and the threshold should be selected based on the priority in the decoded SCI and the priority in the SCI to be transmitted. A resource is excluded if it is indicated or reserved by a decoded SCI and PSSCH/PSCCH RSRP in the associated data resource is above a threshold.
SL-PowerControl field descriptions
sl-MaxTransPower
Indicates the maximum value of the UE's sidelink transmission power on this resource pool when the sidelink transmission is performed only on this resource pool. The unit is dBm. If the sidelink transmission is PSFCH, and multiple resource pools are used, the maximum transmission power for PSFCH is configured as sum of fields sl-maxTransPower over multiple resource pools, as specified in TS 38.101-1.
sl-Alpha-PSSCH-PSCCH
Indicates alpha value for sidelink pathloss based power control for PSCCH/PSSCH when sl-P0-PSSCH-PSCCH is configured. When the field is absent the UE applies the value 1.
sl-P0-PSSCH-PSCCH
Indicates P0 value for sidelink pathloss based power control for PSCCH/PSSCH. If not configured, sidelink pathloss based power control is disabled for PSCCH/PSSCH. When sl-P0-PSSCH-PSCCH-r17 is configured, the UE ignores sl-P0-PSSCH-PSCCH-r16.
dl-Alpha-PSSCH-PSCCH
Indicates alpha value for downlink pathloss based power control for PSCCH/PSSCH when dl-P0-PSSCH-PSCCH is configured. When the field is absent the UE applies the value 1.
dl-P0-PSSCH-PSCCH
Indicates P0 value for downlink pathloss based power control for PSCCH/PSSCH. If not configured, downlink pathloss based power control is disabled for PSCCH/PSSCH. When dl-P0-PSSCH-PSCCH-r17 is configured, the UE ignores dl-P0-PSSCH-PSCCH-r16. A Remote UE which is out of coverage, considers downlink pathloss based power control is disabled for PSCCH/PSSCH when dl-P0-PSSCH-PSCCH is configured.
dl-Alpha-PSFCH
Indicates alpha value for downlink pathloss based power control for PSFCH when dl-P0-PSFCH is configured. When the field is absent the UE applies the value 1. For resource pools configured with PSFCH resources overlapping in time, this field is either not configured in any of the resource pools or configured with the same value for all the resource pools.
dl-P0-PSFCH
Indicates P0 value for downlink pathloss based power control for PSFCH. If not configured, downlink pathloss based power control is disabled for PSFCH. When dl-P0-PSFCH-r17 is configured, the UE ignores dl-P0-PSFCH-r16. For resource pools configured with PSFCH resources overlapping in time, this field is either not configured in any of the resource pools or configured with the same value for all the resource pools.
A Remote UE which is out of coverage, considers downlink pathloss based power control is disabled for PSFCH when dl-P0-PSFCH is configured.
SL-MinMaxMCS-Config field descriptions
sl-MaxMCS-PSSCH
Indicates the maximum MCS value when using the associated MCS table. If no MCS is configured, UE autonomously selects MCS from the full range of values.
sl-MinMCS-PSSCH
Indicates the minimum MCS value when using the associated MCS table. If no MCS is configured, UE autonomously selects MCS from the full range of values.
SL-CPE-StartingPositionsPSCCH-PSSCH field descriptions
sl-Priority
Indicates L1 priority of PSSCH.
sl-CPE-StartingPositions
Indicates a set of candidate CPE starting positions specified in Table 5.3.1-3 of TS 38.211.
Up

 –  SL-RLC-BearerConfigp. 1385

The IE SL-RLC-BearerConfig specifies the SL RLC bearer configuration information for NR sidelink communication.
SL-RLC-BearerConfig information element
SL-RLC-BearerConfig field descriptions
sl-MAC-LogicalChannelConfig
The field is used to configure MAC SL logical channel parameters.
sl-RLC-BearerConfigIndex
The index of the RLC bearer configuration. If the field sl-RLC-BearerConfigIndex-v1800 is present, the UE shall ignore the sl-RLC-BearerConfigIndex-r16 field.
sl-RLC-Config
Determines the RLC mode (UM, AM) and provides corresponding parameters.
sl-ServedRadioBearer
Associates the sidelink RLC Bearer with a sidelink DRB. It indicates the index of SL radio bearer configuration, which is corresponding to the RLC bearer configuration.
Conditional Presence Explanation
LCH-SetupThe field is mandatory present upon creation of a new sidelink logical channel via the dedicated signalling and in case of sidelink DRB configuration via system information and pre-configuration; otherwise the field is optionally present, Need M.
LCH-SetupOnlyThis field is mandatory present upon creation of a new sidelink logical channel via the dedicated signalling and in case of sidelink DRB configuration via system information and pre-configuration. Otherwise, it is absent, Need M.
Up

 –  SL-RLC-BearerConfigIndexp. 1385

The IE SL-RLC-BearerConfigIndex is used to identify a SL RLC bearer configuration.
SL-RLC-BearerConfigIndex information element
Up

 –  SL-RLC-ChannelConfigp. 1386

The IE SL-RLC-ChannelConfig specifies the configuration information for PC5 Relay RLC channel between L2 U2N Relay UE and L2 U2N Remote UE, or between L2 U2U Remote UE and L2 U2U Relay UE.
SL-RLC-ChannelConfig information element
SL-RLC-ChannelConfig field descriptions
sl-MAC-LogicalChannelConfig
The field is used to configure MAC SL logical channel parameters.
sl-RLC-ChannelID
Indicates the PC5 Relay RLC channel in the link between L2 U2N Relay UE and L2 U2N Remote UE, or between L2 U2U Remote UE and L2 U2U Relay UE.
sl-RLC-Config
Determines the RLC mode (UM, AM) and provides corresponding parameters.
sl-PacketDelayBudget
Indicates the Packet Delay Budget for a PC5 Relay RLC channel used in L2 U2N relay operation. Upper bound value for the delay that a packet may experience expressed in unit of 0.5ms.
Up

 –  SL-RLC-ChannelIDp. 1387

The IE SL-RLC-ChannelID is used to identify a PC5 Relay RLC channel in the link between L2 U2N Relay UE and L2 U2N Remote UE, or between L2 U2U Relay UE and L2 U2U Remote UE.
SL-RLC-ChannelID information element
Up

 –  SL-RLC-Configp. 1387

The IE SL-RLC-Config is used to specify the RLC configuration of sidelink DRB. RLC AM configuration is only applicable to the unicast NR sidelink communication.
SL-RLC-Config information element
SL-RLC-Config field descriptions
sl-MaxRetxThreshold
Parameter value of maxRetxThreshold for RLC AM for NR sidelink communications, see TS 38.322. Value t1 corresponds to 1 retransmission, value t2 corresponds to 2 retransmissions and so on.
sl-PollByte
Parameter value of pollByte for RLC AM for NR sidelink communications, see TS 38.322. Value kB25 corresponds to 25 kBytes, value kB50 corresponds to 50 kBytes and so on. infinity corresponds to an infinite amount of kBytes.
sl-PollPDU
Parameter value of pollPDU for RLC AM for NR sidelink communications, seeTS 38.322. Value p4 corresponds to 4 PDUs, value p8 corresponds to 8 PDUs and so on. infinity corresponds to an infinite number of PDUs.
sl-SN-FieldLength
This field indicates the RLC SN field size for NR sidelink communication, see TS 38.322. For groupcast and broadcast, only value size6 (6 bits) is configured for the field sl-SN-FieldLengthUM.
sl-T-PollRetransmit
Timer value of t-PollRetransmit for RLC AM for NR sidelink communications, see TS 38.322, in milliseconds. Value ms5 means 5 ms, value ms10 means 10 ms and so on.
Conditional Presence Explanation
SLRBSetupThe field is mandatory present in case of sidelink DRB setup via the dedicated signalling and in case of sidelink DRB configuration via system information and pre-configuration; otherwise the field is optionally present, need M.
Up

 –  SL-ScheduledConfigp. 1388

The IE SL-ScheduledConfig specifies sidelink communication/ positioning configurations used for network scheduled NR sidelink communication/ positioning.
SL-ScheduledConfig information element
SL-ScheduledConfig field descriptions
sl-CS-RNTI
Indicate the RNTI used to scramble CRC of DCI format 3_0, see TS 38.321.
sl-DCI-ToSL-Trans
Indicate the time gap between DCI reception and the first sidelink transmission scheduled by the DCI (see clause 8.1.2.1 of TS 38.214). Value 1 included in this field corresponds to 1 slot, value 2 corresponds to 2 slots and so on, based on the numerology of sidelink BWP.
sl-PSFCH-ToPUCCH
For dynamic grant and configured grant type 2, this field configures the values (in number of slot lengths) of the PSFCH to PUCCH gap. The field PSFCH-to-HARQ_feedback timing indicator in DCI format 3_0 selects one of the configured values of the PSFCH to PUCCH gap.
sl-RNTI
Indicate the SL-RNTI used for monitoring the network scheduling to transmit NR sidelink communication (i.e. the mode 1).
MAC-MainConfigSL field descriptions
sl-BSR-Config
This field is to configure the sidelink buffer status report.
sl-PrioritizationThres
Indicates the SL priority threshold, which is used to determine whether SL TX is prioritized over UL TX, as specified in TS 38.321. Network does not configure the sl-PrioritizationThres and the ul-PrioritizationThres to the UE separately.
ul-PrioritizationThres
Indicates the UL priority threshold, which is used to determine whether SL TX is prioritized over UL TX, as specified in TS 38.321. Network does not configure the sl-PrioritizationThres and the ul-PrioritizationThres to the UE separately.
Up

 –  SL-SDAP-Configp. 1390

The IE SL-SDAP-Config is used to set the configurable SDAP parameters for a Sidelink DRB.
SL-SDAP-Config information element
SL-SDAP-Config field descriptions
sl-DefaultRB
Indicates whether or not this is the default sidelink DRB for this NR sidelink communication transmission destination. Among all configured instances of SL-SDAP-Config for this destination, this field shall be set to true in at most one instance of SL-SDAP-Config and to false in all other instances.
sl-MappedQoS-Flows
Indicates QoS flows to be mapped to the sidelink DRB. If the field is included in dedicated signalling, it is set to sl-MappedQoS-FlowsListDedicated; otherwise, it is set to sl-MappedQoS-FlowsList.
sl-MappedQoS-FlowsList
Indicates the list of QoS profiles of the NR sidelink communication transmission destination mapped to this sidelink DRB.
sl-MappedQoS-FlowsToAddList
Indicates the list of SL QoS flows ID of the NR sidelink communication transmission destination to be additionally mapped to this sidelink DRB.
sl-MappedQoS-FlowsToReleaseList
Indicates the list of SL QoS flows ID of the NR sidelink communication transmission destination to be released from existing QoS flow to SLRB mapping of this sidelink DRB.
sl-SDAP-Header
Indicates whether or not a SDAP header is present on this sidelink DRB. The field cannot be changed after a sidelink DRB is established. This field is set to present if the field sl-DefaultRB is set to true.
Up

 –  SL-ServingCellInfop. 1391

The IE SL-ServingCellInfo is used to indicate the L2 U2N Relay UE's PCell/camping cell, which is considered as PCell/camping cell by the L2 U2N Remote UEs connecting with this L2 U2N Relay UE.
SL-ServingCellInfo information element
SL-ServingCellInfo field descriptions
sl-CarrierFreqNR
Indicates the DL frequency of the cell indicated by sl-PhysCellId.
sl-PhysCellId
Indicates the PCI of the PCell.
Up

 –  SL-SourceIdentityp. 1391

The IE SL-SourceIdentity is used to identify a source of a NR sidelink communication.
SL-SourceIdentity information element

 –  SL-SRAP-Configp. 1391

The IE SL-SRAP-Config is used to set the configurable SRAP parameters used by L2 U2N Relay UE and L2 U2N Remote UE as specified in TS 38.351.
SL-SRAP-Config information element
SL-SRAP-Config field descriptions
sl-LocalIdentity
Indicates the local UE ID of the L2 U2N Remote UE used in SRAP as specified in TS 38.351.
sl-MappingToAddModList
Indicates the list of mappings between the bearer identity of the L2 U2N Remote UE and the egress RLC channel as specified in TS 38.351 to be added or modified.
sl-MappingToReleaseList
Indicates the list of mappings between the bearer identity of the L2 U2N Remote UE and the egress RLC channel as specified in TS 38.351 to be released.
sl-RemoteUE-RB-Identity
Identity of the end-to-end Uu bearer identity of the L2 U2N Remote UE. The value 3 for the field srb-identity-r17 (i.e., for configuring SRB3) is not supported in this version of the specification.
sl-EgressRLC-ChannelUu
Indicates the egress RLC channel on Uu Hop for uplink transmissions at the L2 U2N Relay UE.
sl-EgressRLC-ChannelPC5
Indicates the egress RLC channel on PC5 Hop for downlink transmissions at the L2 U2N Relay UE and for uplink transmissions at the L2 U2N Remote UE.
Conditional Presence Explanation
L2RelayUEFor L2 U2N Relay UE, the field is optionally present, Need M. Otherwise, it is absent.
Up

 –  SL-SRAP-ConfigU2Up. 1393

The IE SL-SRAP-ConfigU2U is used to set the configurable SRAP parameters used by L2 U2U Relay UE and L2 U2U Remote UE as specified in TS 38.351.
SL-SRAP-ConfigU2U information element
SL-SRAP-ConfigU2U field descriptions
sl-MappingToAddMod-U2U-List
Indicates the list of mappings between the end-to-end sidelink bearer of a given L2 U2U Remote UE and the egress PC5 Relay RLC channel used by L2 U2U Remote UE and L2 U2U Relay UE when acting as Tx UE, as specified in TS 38.351 to be added or modified.
sl-MappingToRelease-U2U-List
Indicates the list of mappings the end-to-end sidelink bearer of a given L2 U2U Remote UE and the egress PC5 Relay RLC channel as specified in TS 38.351 to be released,
sl-EgressRLC-ChannelPC5
Indicates the egress PC5 Relay RLC channel for sidelink transmissions at the L2 U2U Relay UE and at the L2 U2U Remote UE.
sl-RemoteUE-SLRB-Identity
Identity of the end-to-end sidelink bearer identity of the L2 U2U Remote UE.
Up

 –  SL-SyncConfigp. 1393

The IE SL-SyncConfig specifies the configuration information concerning reception of synchronisation signals from neighbouring cells as well as concerning the transmission of synchronisation signals for sidelink communication.
SL-SyncConfig information element
SL-SyncConfig field descriptions
gnss-Sync
If configured, the synchronization configuration is used for SLSS transmission/reception when the UE is synchronized to GNSS. If not configured, the synchronization configuration is used for SLSS transmission/reception when the UE is synchronized to eNB/gNB.
sl-SyncRefMinHyst
Hysteresis when evaluating a SyncRef UE using absolute comparison.
sl-SyncRefDiffHyst
Hysteresis when evaluating a SyncRef UE using relative comparison.
sl-NumSSB-WithinPeriod
Indicates the number of sidelink SSB transmissions within one sidelink SSB period. The applicable values are related to the subcarrier spacing and frequency as follows:
FR1, SCS = 15 kHz: 1
FR1, SCS = 30 kHz: 1, 2
FR1, SCS = 60 kHz: 1, 2, 4
FR2, SCS = 60 kHz: 1, 2, 4, 8, 16, 32
FR2, SCS = 120 kHz: 1, 2, 4, 8, 16, 32, 64
All values in sl-NumSSB-WithinPeriod in sl-SSB-TimeAllocation1 is set to be same across all carrier frequencies configured for UEs performing NR sidelink communication on multiple carrier frequencies, if configured. All values in sl-NumSSB-WithinPeriod in sl-SSB-TimeAllocation2 is set to be same across all carrier frequencies configured for UEs performing NR sidelink communication on multiple carrier frequencies, if configured. All values in sl-NumSSB-WithinPeriod in sl-SSB-TimeAllocation3 is set to be same across all carrier frequencies configured for UEs performing NR sidelink communication on multiple carrier frequencies, if configured.
sl-TimeOffsetSSB
Indicates the slot offset from the start of sidelink SSB period to the first sidelink SSB. All values in sl-TimeOffsetSSB in sl-SSB-TimeAllocation1 is set to be same across all carrier frequencies configured for UEs performing NR sidelink communication on multiple carrier frequencies, if configured. All values in sl-TimeOffsetSSB in sl-SSB-TimeAllocation2 is set to be same across all carrier frequencies configured for UEs performing NR sidelink communication on multiple carrier frequencies, if configured. All values in sl-TimeOffsetSSB in sl-SSB-TimeAllocation3 is set to be same across all carrier frequencies configured for UEs performing NR sidelink communication on multiple carrier frequencies, if configured.
sl-TimeInterval
Indicates the slot interval between neighboring sidelink SSBs. This value is applicable when there are more than one sidelink SSBs within one sidelink SSB period. All values in sl-TimeInterval in sl-SSB-TimeAllocation1 is set to be same across all carrier frequencies configured for UEs performing NR sidelink communication on multiple carrier frequencies, if configured. All values in sl-TimeInterval in sl-SSB-TimeAllocation2 is set to be same across all carrier frequencies configured for UEs performing NR sidelink communication on multiple carrier frequencies, if configured. All values in sl-TimeInterval in sl-SSB-TimeAllocation3 is set to be same across all carrier frequencies configured for UEs performing NR sidelink communication on multiple carrier frequencies, if configured.
sl-SSID
Indicates the ID of sidelink synchronization signal associated with different synchronization priorities.
syncInfoReserved
Reserved for future use.
syncTxThreshIC, syncTxThreshOoC
Indicates the thresholds used while in coverage and out of coverage, respectively. Value 0 corresponds to -infinity, value 1 to -115 dBm, value 2 to -110 dBm, and so on (i.e. in steps of 5 dBm) until value 12, which corresponds to -60 dBm, while value 13 corresponds to +infinity.
Up

 –  SL-Thres-RSRP-Listp. 1395

The IE SL-Thres-RSRP-List indicates a threshold used for sensing based UE autonomous resource selection (see TS 38.215). A resource is excluded if it is indicated or reserved by a decoded SCI and PSSCH/PSCCH RSRP in the associated data resource is above the threshold defined by IE SL-Thres-RSRP-List. A NR sidelink resource is excluded if the corresponding PSFCH transmission occasions overlap with resources indicated or reserved by the decoded EUTRA SCI in time domain and EUTRA PSSCH RSRP in the associated data resource is above the threshold defined by IE sl-NRPSFCH-EUTRA-ThresRSRP-List. A NR sidelink resource is excluded if it is indicated or reserved by the decoded EUTRA SCI and EUTRA PSSCH RSRP in the associated data resource is above the threshold defined by IE sl-NRPSSCH-EUTRA-ThresRSRP-List. Value 0 corresponds to minus infinity dBm, value 1 corresponds to -128dBm, value 2 corresponds to -126dBm, value n corresponds to (-128 + (n-1)*2) dBm and so on, value 66 corresponds to infinity dBm.
SL-Thres-RSRP-List information element
Up

 –  SL-TxPowerp. 1396

The IE SL-TxPower is used to limit the UE's sidelink transmission power on a carrier frequency. The unit is dBm. Value minusinfinity corresponds to -infinity.
SL-TxPower information element
Up

 –  SL-TypeTxSyncp. 1396

The IE SL-TypeTxSync indicates the synchronization reference type.
SL-TypeTxSync information element

 –  SL-UE-SelectedConfigp. 1397

IE SL-UE-SelectedConfig specifies sidelink communication configurations used for UE autonomous resource selection.
SL-UE-SelectedConfig information element
SL-UE-SelectedConfig field descriptions
sl-PrioritizationThres
Indicates the SL priority threshold, which is used to determine whether SL TX is prioritized over UL TX, as specified in TS 38.321. Network does not configure the sl-PrioritizationThres and the ul-PrioritizationThres to the UE separately.
sl-ProbResourceKeep
Indicates the probability with which the UE keeps the current resource when the resource reselection counter reaches zero for sensing based UE autonomous resource selection (see TS 38.321).
sl-PSSCH-TxConfigList
Indicates PSSCH TX parameters such as MCS, sub-channel number, retransmission number, associated to different UE absolute speeds and different synchronization reference types for UE autonomous resource selection.
sl-ReselectAfter
Indicates the number of consecutive skipped transmissions before triggering resource reselection for sidelink communication (see TS 38.321).
ul-PrioritizationThres
Indicates the UL priority threshold, which is used to determine whether SL TX is prioritized over UL TX, as specified in TS 38.321. Network does not configure the sl-PrioritizationThres and the ul-PrioritizationThres to the UE separately.
Up

 –  SL-ZoneConfigp. 1397

The IE SL-ZoneConfig is used to configure the zone ID related parameters.
SL-ZoneConfig information element
SL-ZoneConfig field descriptions
sl-ZoneLength
Indicates the length of each geographic zone.
Up

 –  SLRB-Uu-ConfigIndexp. 1398

The IE SLRB-Uu-ConfigIndex is used to identify a sidelink DRB configuration from the network side.
SLRB-Uu-ConfigIndex information element

Up   Top   ToC