Tech-invite3GPPspaceIETF RFCsSIP
index21222324252627282931323334353637384‑5x

Content for  TS 38.331  Word version:  17.4.0

Top   Top   Up   Prev   Next
1…   4…   5…   5.2.2.4…   5.3…   5.3.3…   5.3.5…   5.3.5.5…   5.3.5.6…   5.3.5.7…   5.3.5.13…   5.3.6…   5.3.8…   5.3.13…   5.3.14…   5.4…   5.5…   5.5.3…   5.5.4…   5.5.5…   5.5a…   5.7…   5.7.4…   5.7.8…   5.8…   5.8.9…   5.8.10…   5.8.11…   5.9…   6…   6.2.2…   6-2-2-25…   6.3…   6.3.2…   6-3-2-27…   6-3-2-49…   6-3-2-73…   6-3-2-95…   6-3-2-108…   6-3-2-134…   6-3-2-162…   6-3-2-188…   6-3-2-213…   6-3-2-243…   6-3-2-271…   6-3-2-297…   6.3.3…   6-3-3-25…   6-3-3-51…   6.3.4…   6.3.5…   6-3-5-25…   6.3.6…   6.4…   7…   9…   11…   A…   A.4…   B…

 

 –  CellAccessRelatedInfop. 518

The IE CellAccessRelatedInfo indicates cell access related information for this cell.
CellAccessRelatedInfo information element
CellAccessRelatedInfo field descriptions
cellReservedForFutureUse
Indicates whether the cell is reserved, as defined in 38.304 [20] for future use. The field is applicable to all PLMNs and NPNs. This field is ignored by IAB-MT.
cellReservedForOtherUse
Indicates whether the cell is reserved, as defined in 38.304 [20]. The field is applicable to all PLMNs. This field is ignored by IAB-MT for cell barring determination, but still considered by NPN capable IAB-MT for determination of an NPN-only cell.
npn-IdentityInfoList
The npn-IdentityInfoList is used to configure a set of NPN-IdentityInfo elements. Each of those elements contains a list of one or more NPN Identities and additional information associated with those NPNs. The total number of PLMNs (identified by a PLMN identity in plmn -IdentityList), PNI-NPNs (identified by a PLMN identity and a CAG-ID), and SNPNs (identified by a PLMN identity and a NID) together in the PLMN-IdentityInfoList and NPN-IdentityInfoList does not exceed 12, except for the NPN-only cells. A PNI-NPN and SNPN can be included only once, and in only one entry of the NPN-IdentityInfoList. In case of NPN-only cells the PLMN-IdentityList contains a single element that does not count to the limit of 12 and the cellIdentity of the first entry of the PLMN-IdentityInfoList is set to the same value as the cellIdentity-r16 of the first entry of the NPN-IdentityInfoList. The NPN index is defined as B+c1+c2+…+c(n-1)+d1+d2+…+d(m-1)+e(i) for the NPN identity included in the n-th entry of NPN-IdentityInfoList and in the m-th entry of npn-Identitylist within that NPN-IdentityInfoList entry, and the i-th entry of its corresponding NPN-Identity, where
  • B is the index used for the last PLMN in the PLMN-IdentittyInfoList; in NPN-only cells B is considered 0;
  • c(j) is the number of NPN index values used in the j-th NPN-IdentityInfoList entry;
  • d(k) is the number of NPN index values used in the k-th npn-IdentityList entry within the n-th NPN-IdentityInfoList entry;
  • e(i) is
    • i if the n-th entry of NPN-IdentityInfoList entry is for SNPN(s);
    • 1 if the n-th entry of NPN-IdentityInfoList entry is for PNI-NPN(s).
plmn-IdentityInfoList
The plmn-IdentityInfoList is used to configure a set of PLMN-IdentityInfo elements. Each of those elements contains a list of one or more PLMN Identities and additional information associated with those PLMNs. A PLMN-identity can be included only once, and in only one entry of the PLMN-IdentityInfoList. The PLMN index is defined as b1+b2+…+b(n-1)+i for the PLMN included at the n-th entry of PLMN-IdentityInfoList and the i-th entry of its corresponding PLMN-IdentityInfo, where b(j) is the number of PLMN-Identity entries in each PLMN-IdentityInfo, respectively.
snpn-AccessInfoList
This list provides access related information for each SNPN in npn-IdentityInfoList, see TS 23.501. The n-th entry of the list contains the access related information of the n-th SNPN in npn-IdentityInfoList.
SNPN-AccessInfo field descriptions
extCH-Supported
Indicates whether the SNPN supports access using credentials from a Credentials Holder as specified in TS 23.501.
extCH-WithoutConfigAllowed
Indicates whether the SNPN allows registration attempts with credentials from a Credentials Holder from UEs that are not explicitly configured to select the SNPN as specified in TS 23.501.
imsEmergencySupportForSNPN
Indicates whether the SNPN supports IMS emergency bearer services for UEs in limited service mode in the cell. If absent, IMS emergency call is not supported by the SNPN in the cell for UEs in limited service mode.
onboardingEnabled
Indicates whether the onboarding SNPN allows registration for onboarding in the cell as specified in TS 23.501.
Up

 –  CellAccessRelatedInfo-EUTRA-5GCp. 520

The IE CellAccessRelatedInfo-EUTRA-5GC indicates cell access related information for an LTE cell connected to 5GC.
CellAccessRelatedInfo-EUTRA-5GC information element
Up

 –  CellAccessRelatedInfo-EUTRA-EPCp. 520

The IE CellAccessRelatedInfo-EUTRA-EPC indicates cell access related information for an LTE cell connected to EPC.
CellAccessRelatedInfo-EUTRA-EPC information element
Up

 –  CellGroupConfigp. 521

The CellGroupConfig IE is used to configure a master cell group (MCG) or secondary cell group (SCG). A cell group comprises of one MAC entity, a set of logical channels with associated RLC entities and of a primary cell (SpCell) and one or more secondary cells (SCells).
CellGroupConfig information element
CC-State field descriptions
dlCarrier
Indicates DL carrier activation state for this carrier and the related active BWP Index, if activated.
ulCarrier
Indicates UL carrier activation state for this carrier and the related active BWP Index, if activated.
CellGroupConfig field descriptions
bap-Address
BAP address of the parent node in cell group.
bh-RLC-ChannelToAddModList
Configuration of the backhaul RLC entities and the corresponding MAC Logical Channels to be added and modified.
bh-RLC-ChannelToReleaseList
List of the backhaul RLC entities and the corresponding MAC Logical Channels to be released.
f1c-TransferPath
The F1-C transfer path that an EN-DC IAB-MT should use for transferring F1-C packets to the IAB-donor-CU. If IAB-MT is configured with lte, IAB-MT can only use LTE leg for F1-C transfer. If IAB-MT is configured with nr, IAB-MT can only use NR leg for F1-C transfer. If IAB-MT is configured with both, it is up to IAB-MT to select an LTE leg or a NR leg for F1-C transfer. If the field is not configured, the IAB node uses the NR leg as the default one.
f1c-TransferPathNRDC
The F1-C transfer path that an NR-DC IAB-MT should use for transferring F1-C packets to the IAB-donor-CU. If IAB-MT is configured with mcg, IAB-MT can only use the MCG for F1-C transfer. If IAB-MT is configured with scg, IAB-MT can only use the SCG for F1-C transfer. If IAB-MT is configured with both, it is up to IAB-MT to select the MCG or the SCG for F1-C transfer.
mac-CellGroupConfig
MAC parameters applicable for the entire cell group.
rlc-BearerToAddModList
Configuration of the MAC Logical Channel, the corresponding RLC entities and association with radio bearers.
reportUplinkTxDirectCurrent
Enables reporting of uplink and supplementary uplink Direct Current location information upon BWP configuration and reconfiguration. This field is only present when the BWP configuration is modified or any serving cell is added or removed. This field is absent in the IE CellGroupConfig when provided as part of RRCSetup message. If UE is configured with SUL carrier, UE reports both UL and SUL Direct Current locations.
reportUplinkTxDirectCurrentMoreCarrier
Enables reporting of uplink Direct Current location information when the UE is configured with intra-band CA. This field is absent in the IE CellGroupConfig when provided as part of RRCSetup message. The UE only reports the uplink Direct Current location information that are related to the indicated cc-CombinationList. The network does not include carriers which locate in DL only spectrum described in clause 5.3A.4 of TS 38.101-2 and defined by Fsd according to Table 5.3A.4-3 in FR2 in the IntraBandCC-CombinationReqList. I.e. DL-only carrier in FR2 frequency spectrum is not used to calculate the default DC location.
reportUplinkTxDirectCurrentTwoCarrier
Enables reporting of uplink Direct Current location information when the UE is configured with uplink intra-band CA with two carriers. This field is absent in the IE CellGroupConfig when provided as part of RRCSetup message.
rlc-BearerToReleaseListExt
List of the RLC entities and the corresponding MAC Logical Channels to be released for multicast MRBs.
rlmInSyncOutOfSyncThreshold
BLER threshold pair index for IS/OOS indication generation, see TS 38.133, table 8.1.1-1. n1 corresponds to the value 1. When the field is absent, the UE applies the value 0. Whenever this is reconfigured, UE resets N310 and N311, and stops T310, if running. Network does not include this field.
sCellSIB20
This field is used to transfer SIB20 of the SCell in order to allow the UE for MBS broadcast reception on SCell. The network configures this field only for a single SCell at a time.
sCellState
Indicates whether the SCell shall be considered to be in activated state upon SCell configuration. If the field is included for an SCell configured with TRS for fast activation of the SCell, such TRS is not used for the corresponding SCell.
sCellToAddModList
List of secondary serving cells (SCells) to be added or modified.
sCellToReleaseList
List of secondary serving cells (SCells) to be released.
secondaryDRX-GroupConfig
The field is used to indicate whether the SCell belongs to the secondary DRX group. All serving cells in the secondary DRX group shall belong to one Frequency Range and all serving cells in the legacy DRX group shall belong to another Frequency Range.
simultaneousSpatial-UpdatedList1, simultaneousSpatial-UpdatedList2
List of serving cells which can be updated simultaneously for spatial relation with a MAC CE. The simultaneousSpatial-UpdatedList1 and simultaneousSpatial-UpdatedList2 shall not contain same serving cells. Network should not configure serving cells that are configured with a BWP with two different values for the coresetPoolIndex in these lists.
simultaneousTCI-UpdateList1, simultaneousTCI-UpdateList2
List of serving cells which can be updated simultaneously for TCI relation with a MAC CE. The simultaneousTCI-UpdateList1 and simultaneousTCI-UpdateList2 shall not contain same serving cells. Network should not configure serving cells that are configured with a BWP with two different values for the coresetPoolIndex in these lists.
simultaneousU-TCI-UpdateList1, simultaneousU-TCI-UpdateList2, simultaneousU-TCI-UpdateList3, simultaneousU-TCI-UpdateList4
List of serving cells for which the Unified TCI States Activation/Deactivation MAC CE applies simultaneously, as specified in clause 6.1.3.47 of TS 38.321. The different lists shall not contain same serving cells. Network only configures in these lists serving cells that are configured with unifiedTCI-StateType.
spCellConfig
Parameters for the SpCell of this cell group (PCell of MCG or PSCell of SCG).
uplinkTxSwitchingOption
Indicates which option is configured for dynamic UL Tx switching for inter-band UL CA or (NG)EN-DC. The field is set to switchedUL if network configures option 1 as specified in TS 38.214, or dualUL if network configures option 2 as specified in TS 38.214. Network always configures UE with a value for this field in inter-band UL CA case and (NG)EN-DC case where UE supports dynamic UL Tx switching.
uplinkTxSwitchingPowerBoosting
Indicates whether the UE is allowed to enable 3dB boosting on the maximum output power for transmission on carrier2 under the operation state in which 2-port transmission can be supported on carrier2 for inter-band UL CA case with dynamic UL Tx switching as defined in TS 38.101-1. Network can only configure this field for dynamic UL Tx switching in inter-band UL CA case with power Class 3 as defined in TS 38.101-1.
uplinkTxSwitching-2T-Mode
Indicates 2Tx-2Tx switching mode is configured for inter-band UL CA or SUL, in which the switching gap duration for a triggered uplink switching (as specified in TS 38.214) is equal to the switching time capability value reported for the switching mode.
If this field is absent and uplinkTxSwitching is configured, it is interpreted that 1Tx-2Tx UL Tx switching is configured as specified in TS 38.214. In this case, there is one uplink (or one uplink band in case of intra-band) configured with uplinkTxSwitching, on which the maximum number of antenna ports among all configured P-SRS/A-SRS and activated SP-SRS resources should be 1 and non-codebook based UL MIMO is not configured.
uplinkTxSwitching-DualUL-TxState
Indicates the state of Tx chains if the state of Tx chains after the UL Tx switching is not unique (as specified in TS 38.214) in case of 2Tx-2Tx switching is configured and uplinkTxSwitchingOption is set to dualUL. Value oneT indicates 1Tx is assumed to be supported on the carriers on each band, value twoT indicates 2Tx is assumed to be supported on that carrier.
uu-RelayRLC-ChannelToAddModList
List of the Uu RLC entities and the corresponding MAC Logical Channels to be added or modified.
uu-RelayRLC-ChannelToReleaseList
List of the Uu RLC entities and the corresponding MAC Logical Channels to be released.
DeactivatedSCG-Config field descriptions
bfd-and-RLM
If the field is set to true, the UE shall perform RLM and BFD on the PSCell when the SCG is deactivated and the network ensures that beamFailure-r17 is not configured in the radioLinkMonitoringConfig of the DL BWP of the PSCell in which the UE performs BFD. If set to false, the UE is not required to perform RLM and BFD on the PSCell when the SCG is deactivated.
DAPS-UplinkPowerConfig field descriptions
p-DAPS-Source
The maximum total transmit power to be used by the UE in the source cell group during DAPS handover.
p-DAPS-Target
The maximum total transmit power to be used by the UE in the target cell group during DAPS handover.
uplinkPowerSharingDAPS-Mode
Indicates the uplink power sharing mode that the UE uses in DAPS handover (see TS 38.213).
GoodServingCellEvaluation field descriptions
offset
The parameter "X" (dB) for the good serving cell quality criterion in RRC_CONNECTED, for a cell operating in FR1 and FR2, respectively. If this field is absent, the UE applies the (default) value of 0 dB for "X".
IAB-ResourceConfig field descriptions
iab-ResourceConfigID
This ID is used to indicate the specific resource configuration addressed by the MAC CEs specified in TS 38.321.
periodicitySlotList
Indicates the periodicity in ms of the list of slot indexes indicated in slotList.
slotList
Indicates the list of slot indexes to which the information indicated in the specific MAC CE applies to, as specified in TS 38.321. The values of the entries in the slotList are strictly less than the value of the periodicitySlotList.
slotListSubcarrierSpacing
Subcarrier spacing used as reference for the slotList configuration.
Only the following values are applicable depending on the used frequency:
FR1: 15 or 30 kHz
FR2-1: 60 or 120 kHz
FR2-2: 120 or 480 kHz
ReconfigurationWithSync field descriptions
rach-ConfigDedicated
Random access configuration to be used for the reconfiguration with sync (e.g. handover). The UE performs the RA according to these parameters in the firstActiveUplinkBWP (see UplinkConfig).
smtc
The SSB periodicity/offset/duration configuration of target cell for NR PSCell change and NR PCell change. The network sets the periodicityAndOffset to indicate the same periodicity as ssb-periodicityServingCell in spCellConfigCommon or sets to the same periodicity as ssb-Periodicity-r17 in nonCellDefiningSSB-r17 if the first active DL BWP included in this RRC message is configured with nonCellDefiningSSB-r17 for RedCap.
For case of NR PCell change, the smtc is based on the timing reference of (source) PCell. For case of NR PSCell change, it is based on the timing reference of source PSCell.
If both this field and targetCellSMTC-SCG are absent, the UE uses the SMTC in the measObjectNR having the same SSB frequency and subcarrier spacing, as configured before the reception of the RRC message. For a RedCap UE, if the first active DL BWP included in this RRC message is configured with nonCellDefiningSSB-r17, this field corresponds to the NCD-SSB indicated by nonCellDefiningSSB-r17, otherwise, this field corresponds to the CD-SSB indicated by absoluteFrequencySSB in frequencyInfoDL.
ReportUplinkTxDirectCurrentMoreCarrier field descriptions
IntraBandCC-Combination
Indicates the state of the carriers and BWPs indexes of the carriers in a CC combination, each carrier in this combination corresponds to an entry in servCellIndexList with same order. This IE shall have the same size as servCellIndexList.
IntraBandCC-CombinationReqList
Indicates the list of the requested carriers/BWPs combinations for an intra-band CA component.
servCellIndexList
indicates the list of cell index for an intra-band CA component.
SCellConfig field descriptions
goodServingCellEvaluationBFD
Indicates the criterion for a UE to detect the good serving cell quality for BFD relaxation in an SCell in RRC_CONNECTED. This field is always configured when the network enables BFD relaxation for the UE in this SCell. This field is absent if failureDetectionSetN is present for the SCell.
preConfGapStatus
Indicates whether the pre-configured measurement gaps (i.e. the gaps configured with preConfigInd) are activated or deactivated while this SCell is deactivated. If this field is configured, the UE shall apply network-controlled mechanism for activation and deactivation of the pre-configured measurement gaps, otherwise the UE shall apply the autonomous activation/deactivation mechanism, as specified in TS 38.133. The first/leftmost bit corresponds to the measurement gap with gap ID 1, the second bit corresponds to measurement gap with gap ID 2, and so on. Value 0 indicates that the corresponding pre-configured measurement gap is deactivated while value 1 indicates that the corresponding pre-configured measurement gap is activated. The UE shall ignore the bit if the corresponding measurement gap is not a pre-configured measurement gap.
smtc
The SSB periodicity/offset/duration configuration of target cell for NR SCell addition. The network sets the periodicityAndOffset to indicate the same periodicity as ssb-periodicityServingCell in sCellConfigCommon. The smtc is based on the timing of the SpCell of associated cell group. In case of inter-RAT handover to NR, the timing reference is the NR PCell. In case of intra-NR PCell change (standalone NR) or NR PSCell change (EN-DC), the timing reference is the target SpCell. If the field is absent, the UE uses the SMTC in the measObjectNR having the same SSB frequency and subcarrier spacing, as configured before the reception of the RRC message.
SpCellConfig field descriptions
deactivatedSCG-Config
Configuration applicable when the SCG is deactivated. The network always configures this field before or when indicating that the SCG is deactivated in an RRCReconfiguration, RRCResume, E-UTRA RRCConnectionReconfiguration or E-UTRA RRCConnectionResume message.
goodServingCellEvaluationBFD
Indicates the criterion for a UE to detect the good serving cell quality for BFD relaxation in the SpCell in RRC_CONNECTED. The field is always configured when the network enables BFD relaxation for the UE in this SpCell. This field is absent if failureDetectionSetN is present for the SpCell.
goodServingCellEvaluationRLM
Indicates the criterion for a UE to detect the good serving cell quality for RLM relaxation in the SpCell in RRC_CONNECTED. The field is always configured when the network enables RLM relaxation for the UE in this SpCell.
lowMobilityEvaluationConnected
Indicates the criterion for a UE to detect low mobility in RRC_CONNECTED in an SpCell. The s-SearchDeltaP-Connected is the parameter "SSearchDeltaP-connected". Value dB3 corresponds to 3 dB, dB6 corresponds to 6 dB and so on. The t-SearchDeltaP-Connected is the parameter "TSearchDeltaP-Connected". Value s5 means 5 seconds, value s10 means 10 seconds and so on. Low mobility criterion is configured in NR PCell for the case of NR SA/ NR CA/ NE-DC/NR-DC, and in the NR PSCell for the case of EN-DC.
reconfigurationWithSync
Parameters for the synchronous reconfiguration to the target SpCell.
rlf-TimersAndConstants
Timers and constants for detecting and triggering cell-level radio link failure. For the SCG, rlf-TimersAndConstants can only be set to setup and is always included at SCG addition.
servCellIndex
Serving cell ID of a PSCell. The PCell of the Master Cell Group uses ID = 0.
SL-PathSwitchConfig field descriptions
targetRelayUE-Identity
Indicates the L2 source ID of the target L2 U2N Relay UE during path switch.
T420
Indicates the timer value of T420 to be used during path switch.
Conditional Presence Explanation
2TxThe field is optionally present, Need R, if uplinkTxSwitching is configured; otherwise it is absent, Need R.
BWP-ReconfigThe field is optionally present, Need N, if the BWPs are reconfigured or if serving cells are added or removed. Otherwise it is absent.
DirectToIndirect-PathSwitchThe field is mandatory present for the L2 U2N remote UE at path switch to the target L2 U2N Relay UE. It is absent otherwise.
DRX-Config2The field is optionally present, Need N, if drx-ConfigSecondaryGroup is configured. It is absent otherwise.
PreConfigMGThe field is optionally present, Need R, if there is at least one per UE gap configured with preConfigInd or there is at least one per FR gap of the same FR which the SCell belongs to and configured with preConfigInd. It is absent, Need R, otherwise.
ReconfWithSyncThe field is mandatory present in the RRCReconfiguration message:
  • in each configured CellGroupConfig for which the SpCell changes,
  • in the masterCellGroup:
    • at change of AS security key derived from KgNB,
    • in an RRCReconfiguration message contained in a DLInformationTransferMRDC message,
    • path switch of L2 U2N remote UE to the target PCell,
    • path switch of L2 U2N remote UE to the target L2 U2N Relay UE,
  • in the secondaryCellGroup at:
    • PSCell addition,
    • SCG resume with NR-DC or (NG)EN-DC,
    • update of required SI for PSCell,
    • change of AS security key derived from S-KgNB in NR-DC while the UE is configured with at least one radio bearer with keyToUse set to secondary and that is not released by this RRCReconfiguration message,
    • MN handover in (NG)EN-DC.
Otherwise, it is optionally present, need M. The field is absent in the masterCellGroup in RRCResume and RRCSetup messages and is absent in the masterCellGroup in RRCReconfiguration messages if source configuration is not released during DAPS handover.
SCellAddThe field is mandatory present upon SCell addition; otherwise it is absent, Need M.
SCellAddModThe field is mandatory present upon SCell addition; otherwise it is optionally present, need M.
SCellAddSyncThe field is optionally present, Need N:
  • in the masterCellGroup at
    • SCell addition,
    • reconfiguration with sync,
    • resume of an RRC connection.
  • in the secondaryCellGroup, when the SCG is not indicated as deactivated at:
    • SCG activation while the SCG was previously deactivated,
    • SCell addition,
    • reconfiguration with sync.
It is absent otherwise.
SCGThe field is mandatory present in an SpCellConfig for the PSCell. It is absent otherwise.
SCG-OptThe field is optionally present, Need M, in an SpCellConfig for the PSCell. It is absent otherwise.
Up

 –  CellGroupIdp. 531

The IE CellGroupId is used to identify a cell group. Value 0 identifies the master cell group. Other values identify secondary cell groups. In this version of the specification only values 0 and 1 are supported.
CellGroupId information element
Up

 –  CellIdentityp. 531

The IE CellIdentity is used to unambiguously identify a cell within a PLMN/SNPN.
CellIdentity information element
Up

 –  CellReselectionPriorityp. 531

The IE CellReselectionPriority concerns the absolute priority of the concerned carrier frequency, as used by the cell reselection procedure. Corresponds to parameter "priority" in TS 38.304. Value 0 means lowest priority. The UE behaviour for the case the field is absent, if applicable, is specified in TS 38.304.
CellReselectionPriority information element
Up

 –  CellReselectionSubPriorityp. 532

The IE CellReselectionSubPriority indicates a fractional value to be added to the value of cellReselectionPriority to obtain the absolute priority of the concerned carrier frequency for E-UTRA and NR. Value oDot2 corresponds to 0.2, value oDot4 corresponds to 0.4 and so on.
CellReselectionSubPriority information element
Up

 –  CFR-ConfigMulticast |R17|p. 532

The IE CFR-ConfigMulticast indicates UE specific common frequency resource configuration for multicast for one dedicated BWP.
CFR-ConfigMulticast information element
CFR-ConfigMulticast field descriptions
locationAndBandwidthMulticast
Frequency domain location and bandwidth for MBS multicast. The value of the field shall be interpreted as resource indicator value (RIV) as defined TS 38.214 with assumptions as described in clause 12 of TS 38.213, i.e. setting N^size_BWP=275. The first PRB is a PRB determined by subcarrierSpacing of the associated BWP and offsetToCarrier corresponding to this subcarrier spacing. If not configured, the UE applies the value of locationAndBandwidth of the DL BWP in which the cfr-ConfigMulticast is configured.
pdcch-ConfigMulticast
UE specific group-common PDCCH configuration for MBS multicast for one CFR.
pdsch-ConfigMulticast
UE specific group-common PDSCH configuration for MBS multicast for one CFR.
sps-ConfigMulticastToAddModList
Indicates a list of one or more DL SPS configurations for MBS multicast.
sps-ConfigMulticastToReleaseList
Indicates a list of one or more DL SPS configurations to be released. The NW may release a SPS configuration at any time.
Up

 –  CGI-InfoEUTRAp. 533

The IE CGI-InfoEUTRA indicates EUTRA cell access related information, which is reported by the UE as part of E-UTRA report CGI procedure.
CGI-InfoEUTRA information element
Up

 –  CGI-InfoEUTRALogging |R16|p. 533

The IE CGI-InfoEUTRALogging indicates EUTRA cell related information, which is reported by the UE as part of RLF reporting procedure.
CGI-InfoEUTRALogging information element
CGI-InfoEUTRALogging field descriptions
cellIdentity-eutra-epc, cellIdentity-eutra-5GC
Unambiguously identify a cell within the context of the PLMN. It belongs the first PLMN entry of plmn-IdentityList (when connected to EPC) or of plmn-IdentityList-r15 (when connected to 5GC) in SystemInformationBlockType1.
plmn-Identity-eutra-epc, plmn-Identity-eutra-5GC
Identifies the PLMN of the cell for the reported cellIdentity: the first PLMN entry of plmn-IdentityList (when connected to EPC) or of plmn-IdentityList-r15 (when connected to 5GC) in SystemInformationBlockType1 that contained the reported cellIdentity.
trackingAreaCode-eutra-epc, trackingAreaCode-eutra-5gc
Indicates Tracking Area Code to which the cell indicated by cellIdentity-eutra-epc, cellIdentity-eutra-5GC belongs.
Up

 –  CGI-InfoNRp. 534

The IE CGI-InfoNR indicates cell access related information, which is reported by the UE as part of report CGI procedure.
CGI-InfoNR information element
-
CGI-InfoNR field descriptions
noSIB1
Contains ssb-SubcarrierOffset and pdcch-ConfigSIB1 fields acquired by the UE from MIB of the cell for which report CGI procedure was requested by the network in case SIB1 was not broadcast by the cell.
cellReservedForOtherUse
Contains cellReservedForOtherUse field acquired by the UE that supports nr-CGI-Reporting-NPN from SIB1 of the cell for which report CGI procedure was requested by the network.
Up

 –  CGI-Info-Logging |R16|p. 535

The IE CGI-Info-Logging indicates the NR Cell Global Identifier (NCGI) for logging purposes (e.g. RLF report), the globally unique identity, and the TAC information of a cell in NR.
CGI-Info-Logging information element
CGI-Info-Logging field descriptions
cellIdentity
Unambiguously identify a cell within the context of the PLMN. It belongs the first PLMN-IdentityInfo IE of PLMN-IdentityInfoList in SIB1.
plmn-Identity
Identifies the PLMN of the cell for the reported cellIdentity: the first PLMN entry of plmn-IdentityList (in SIB1) in the instance of PLMN-IdentityInfoList that contained the reported cellIdentity.
trackingAreaCode
Indicates Tracking Area Code to which the cell indicated by cellIdentity field belongs.
Up

 –  CLI-RSSI-Range |R16|p. 536

The IE CLI-RSSI-Range specifies the value range used in CLI-RSSI measurements and thresholds. The integer value for CLI-RSSI measurements is according to Table 10.1.22.2.2-1 in TS 38.133.
CLI-RSSI-Range information element
Up

 –  CodebookConfigp. 536

The IE CodebookConfig is used to configure codebooks of Type-I and Type-II (see clause 5.2.2.2 of TS 38.214).
CodebookConfig information element
CodebookConfig field descriptions
codebookMode
CodebookMode as specified in clause 5.2.2.2.2 of TS 38.214.
codebookType
CodebookType including possibly sub-types and the corresponding parameters for each (see clause 5.2.2.2 of TS 38.214).
n1-n2-codebookSubsetRestriction
Number of antenna ports in first (n1) and second (n2) dimension and codebook subset restriction (see clause 5.2.2.2.3 of TS 38.214).
Number of bits for codebook subset restriction is CEIL(log2(nchoosek(O1*O2,4)))+8*n1*n2 where nchoosek(a,b) = a!/(b!(a-b)!).
n1-n2
Number of antenna ports in first (n1) and second (n2) dimension and codebook subset restriction (see clause 5.2.2.2.1 of TS 38.214).
ng-n1-n2
Codebook subset restriction for Type I Multi-panel codebook (see clause 5.2.2.2.2 of TS 38.214).
numberOfBeams
Number of beams, L, used for linear combination.
numberOfPMI-SubbandsPerCQI-Subband
Field indicates how PMI subbands are defined per CQI subband according to clause 5.2.2.2.5, and 5.2.2.2.7 of TS 38.214.
paramCombination
Field describes supported parameter combination (M, α, β) as specified in TS 38.214.
phaseAlphabetSize
The size of the PSK alphabet, QPSK or 8-PSK.
portSelectionSamplingSize
The size of the port selection codebook (parameter d), see clause 5.2.2.2.6 of TS 38.214.
ri-Restriction
Restriction for RI for TypeI-MultiPanel-RI-Restriction (see clause 5.2.2.2.2 of TS 38.214).
subbandAmplitude
If subband amplitude reporting is activated (true).
twoTX-CodebookSubsetRestriction
Codebook subset restriction for 2TX codebook (see clause 5.2.2.2.1 of TS 38.214).
typeI-SinglePanel-codebookSubsetRestriction-i2
i2 codebook subset restriction for Type I Single-panel codebook used when reportQuantity is CRI/Ri/i1/CQI (see clause 5.2.2.2.1 of TS 38.214).
typeI-SinglePanel-ri-Restriction
Restriction for RI for TypeI-SinglePanel-RI-Restriction (see clause 5.2.2.2.1 of TS 38.214).
typeI-SinglePanel-Group1, typeI-SinglePanel-Group2
Configures codebooks for CSI calculation when UE is configured with two CMR Groups with CMRGroupingAndPairing in the NZP-CSI-RS-ResourceSet associated with the CSI-ReportConfig. Network configures the same number of ports for both codebooks.
typeI-SinglePanel-ri-RestrictionSDM, typeI-SinglePanel-ri-RestrictionSTRP
Restriction for RI for N Resource Pairs when two CMR Groups are configured with CMRGroupingAndPairing in the NZP-CSI-RS-ResourceSet associated with the CSI-ReportConfig (see clause 5.2.1.4.2 of TS 38.214).
typeII-PortSelectionRI-Restriction
Restriction for RI for TypeII-PortSelection-RI-Restriction (see clauses 5.2.2.2.4 and 5.2.2.2.6 of TS 38.214).
typeII-RI-Restriction
Restriction for RI for TypeII-RI-Restriction (see clauses 5.2.2.2.3 and 5.2.2.2.5 of TS 38.214).
valueOfN
Field provides the value of parameter N as specified in clause 5.2.2.2.7 of TS 38.214. The field is present only when M=2 set by paramCombination, see TS 38.214.
Up

 –  CommonLocationInfo |R16|p. 542

The IE CommonLocationInfo is used to transfer detailed location information available at the UE to correlate measurements and UE position information.
CommonLocationInfo information element
CommonLocationInfo field descriptions
gnss-TOD-msec
Parameter type gnss-TOD-msec defined in TS 37.355. The first/leftmost bit of the first octet contains the most significant bit.
locationTimeStamp
Parameter type DisplacementTimeStamp defined in TS 37.355. The first/leftmost bit of the first octet contains the most significant bit.
locationCoordinate
Parameter type LocationCoordinates defined in TS 37.355. The first/leftmost bit of the first octet contains the most significant bit.
locationError
Parameter LocationError defined in TS 37.355. The first/leftmost bit of the first octet contains the most significant bit.
locationSource
Parameter LocationSource defined in TS 37.355. The first/leftmost bit of the first octet contains the most significant bit.
velocityEstimate
Parameter type Velocity defined in TS 37.355. The first/leftmost bit of the first octet contains the most significant bit.
Up

 –  CondReconfigId |R16|p. 542

The IE CondReconfigId is used to identify a CHO, CPA or CPC configuration.
CondReconfigId information element

 –  CondReconfigToAddModList |R16|p. 543

The IE CondReconfigToAddModList concerns a list of conditional reconfigurations to add or modify, with for each entry the condReconfigId and the associated condExecutionCond/condExecutionCondSCG and condRRCReconfig.
CondReconfigToAddModList information element
CondReconfigToAddMod field descriptions
condExecutionCond
The execution condition that needs to be fulfilled in order to trigger the execution of a conditional reconfiguration for CHO, CPA, intra-SN CPC without MN involvement or MN initiated inter-SN CPC. When configuring 2 triggering events (Meas Ids) for a candidate cell, the network ensures that both refer to the same measObject. For CHO, if the network configures condEventD1 or condEventT1 for a candidate cell, the network configures a second triggering event condEventA3, condEventA4 or condEventA5 for the same candidate cell. The network does not configure both condEventD1 and condEventT1 for the same candidate cell. For CHO in terrestrial networks, the network does not indicate a MeasId associated with condEventA4. For CPA and for MN-initiated inter-SN CPC, the network only indicates MeasId(s) associated with condEventA4. For intra-SN CPC, the network only indicates MeasId(s) associated with condEventA3 or condEventA5.
condExecutionCondSCG
Contains execution condition that needs to be fulfilled in order to trigger the execution of a conditional reconfiguration for SN initiated inter-SN CPC. The Meas Ids refer to the measConfig associated with the SCG. When configuring 2 triggering events (Meas Ids) for a candidate cell, network ensures that both refer to the same measObject. For each condReconfigId, the network always configures either condExecutionCond or condExecutionCondSCG (not both). The network only indicates MeasId(s) associated with condEventA3 or condEventA5.
condRRCReconfig
The RRCReconfiguration message to be applied when the condition(s) are fulfilled. The RRCReconfiguration message contained in condRRCReconfig cannot contain the field conditionalReconfiguration or the field daps-Config.
Conditional Presence Explanation
condReconfigAddThe field is mandatory present when a condReconfigId is being added. Otherwise the field is optional, need M.
Up

 –  ConditionalReconfiguration |R16|p. 544

The IE ConditionalReconfiguration is used to add, modify and release the configuration of conditional reconfiguration.
ConditionalReconfiguration information element
ConditionalReconfiguration field descriptions
attemptCondReconfig
If present, the UE shall perform conditional reconfiguration if selected cell is a target candidate cell and it is the first cell selection after failure as described in clause 5.3.7.3.
condReconfigToAddModList
List of the configuration of candidate SpCells to be added or modified for CHO, CPA or CPC.
condReconfigToRemoveList
List of the configuration of candidate SpCells to be removed.
Conditional Presence Explanation
CHOThe field is optional present, Need R, if the UE is configured with at least a candidate SpCell for CHO. Otherwise the field is not present.
Up

 –  ConfiguredGrantConfigp. 545

The IE ConfiguredGrantConfig is used to configure uplink transmission without dynamic grant according to two possible schemes. The actual uplink grant may either be configured via RRC (type1) or provided via the PDCCH (addressed to CS-RNTI) (type2). Multiple Configured Grant configurations may be configured in one BWP of a serving cell.
ConfiguredGrantConfig information element
ConfiguredGrantConfig field descriptions
antennaPort
Indicates the antenna port(s) to be used for this configuration, and the maximum bitwidth is 5. See clause 6.1.2 of TS 38.214, and clause 7.3.1 of TS 38.212. The UE ignores this field in case of CG-SDT.
autonomousTx
If this field is present, the Configured Grant configuration is configured with autonomous transmission, see TS 38.321.
betaOffsetCG-UCI
Beta offset for CG-UCI in CG-PUSCH, see clause 9.3 of TS 38.213.
cg-betaOffsetsCrossPri0, cg-betaOffsetsCrossPri1
Selection between and configuration of dynamic and semi-static beta-offset for multiplexing HARQ-ACK in CG-PUSCH with different priorities.
The field cg-betaOffsetsCrossPri0 indicates multiplexing LP HARQ-ACK in HP CG-PUSCH. This field is configured only if phy-PriorityIndex-r16 is configured with value p1.
The field cg-betaOffsetsCrossPri1 indicates multiplexing HP HARQ-ACK in LP CG-PUSCH. This field is configured only if phy-PriorityIndex-r16 is configured with value p0.
cg-COT-SharingList
Indicates a table for COT sharing combinations (see clause 4.1.3 of TS 37.213). One row of the table can be set to noCOT-Sharing to indicate that there is no channel occupancy sharing. If the cg-RetransmissionTimer-r16 is configured and the UE operates as an initiating device in semi-static channel access mode (see clause 4.3 of TS 37.213), then cg-COT-SharingList-r16 is configured.
cg-COT-SharingOffset
Indicates the offset from the end of the slot where the COT sharing indication in UCI is enabled where the offset in symbols is equal to 14*n, where n is the signaled value for cg-COT-SharingOffset. Applicable when ul-toDL-COT-SharingED-Threshold-r16 is not configured (see clause 4.1.3 of TS 37.213).
cg-DMRS-Configuration
DMRS configuration (see clause 6.1.2.3 of TS 38.214).
cg-minDFI-Delay
Indicates the minimum duration (in unit of symbols) from the ending symbol of the PUSCH to the starting symbol of the PDCCH containing the downlink feedback indication (DFI) carrying HARQ-ACK for this PUSCH. The HARQ-ACK received before this minimum duration is not considered as valid for this PUSCH (see clause 10.5 of TS 38.213). The following minimum duration values are supported, depending on the configured subcarrier spacing [symbols]:
15 kHz: 7, m*14, where m = {1, 2, 3, 4}
30 kHz: 7, m*14, where m = {1, 2, 3, 4, 5, 6, 7, 8}
60 kHz: 7, m*14, where m = {1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16}
120 kHz: 7, m*14, where m = {1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32}
480 kHz: m*14, where m = {2, 4, 8, 12, 16, 20, 24, 28, 32, 36, 40, 44, 48, 52, 56, 60, 64, 68, 72, 76, 80, 84, 88, 92, 96, 100, 104, 108, 112, 116, 120, 124, 128}
960 kHz: m*14, where m = {4, 8, 16, 24, 32, 40, 48, 56, 64, 72, 80, 88, 96, 104, 112, 120, 128, 136, 144, 152, 160, 168, 176, 184, 192, 200, 208, 216, 224, 232, 240, 248, 256}
cg-nrofPUSCH-InSlot
Indicates the number of consecutive PUSCH configured to CG within a slot where the SLIV indicating the first PUSCH and additional PUSCH appended with the same length (see clause 6.1.2.3 of TS 38.214). The network can only configure this field if cg-RetransmissionTimer is configured.
cg-nrofSlots
Indicates the number of allocated slots in a configured grant periodicity following the time instance of configured grant offset (see clause 6.1.2.3 of TS 38.214). cg-nrofSlots-r17 is only applicable for operation with shared spectrum channel access in FR2-2. When cg-nrofSlots-r17 is configured, the UE shall ignore cg-nrofSlots-r16. The network can only configure this field if cg-RetransmissionTimer is configured.
cg-RetransmissionTimer
Indicates the initial value of the configured retransmission timer (see TS 38.321) in multiples of periodicity. The value of cg-RetransmissionTimer is always less than or equal to the value of configuredGrantTimer. This field is always configured together with harq-ProcID-Offset. This field is not configured for operation in licensed spectrum or simultaneously with harq-ProcID-Offset2. The network does not configure this field for CG-SDT.
cg-StartingOffsets
This field is not applicable for a UE which is allowed to operate as an initiating device in semi-static channel access mode, i.e., not applicable for a UE configured with UE FFP parameters (e.g. period, offset) regardless whether the UE would initiate its own COT or would share gNB's COT.
cg-UCI-Multiplexing
If present, this field indicates that in the case of PUCCH overlapping with CG-PUSCH(s) within a PUCCH group, the CG-UCI and HARQ-ACK are jointly encoded (see clause 9 of TS 38.213).
configuredGrantConfigIndex
Indicates the index of the Configured Grant configurations within the BWP.
configuredGrantConfigIndexMAC
Indicates the index of the Configured Grant configurations within the MAC entity.
configuredGrantTimer
Indicates the initial value of the configured grant timer (see TS 38.321) in multiples of periodicity. When cg-RetransmissonTimer is configured, if HARQ processes are shared among different configured grants on the same BWP, configuredGrantTimer * periodicity is set to the same value for the configurations that share HARQ processes on this BWP. The value of the extension configuredGrantTimer is 2 times the configured value.
dmrs-SeqInitialization
The network configures this field if transformPrecoder is disabled or when the value of sdt-NrofDMRS-Sequences is set to 1. Otherwise, the field is absent.
frequencyDomainAllocation
Indicates the frequency domain resource allocation, see clause 6.1.2 of TS 38.214, and clause 7.3.1 of TS 38.212).
frequencyHopping
The value intraSlot enables 'Intra-slot frequency hopping' and the value interSlot enables 'Inter-slot frequency hopping'. If the field is absent, frequency hopping is not configured. The field frequencyHopping applies to configured grant for 'pusch-RepTypeA' (see clause 6.3.1 of TS 38.214).
frequencyHoppingOffset
Frequency hopping offset used when frequency hopping is enabled (see clause 6.1.2 and clause 6.3 of TS 38.214).
frequencyHoppingPUSCH-RepTypeB
Indicates the frequency hopping scheme for Type 1 CG when pusch-RepTypeIndicator is set to 'pusch-RepTypeB' (see clause 6.1 of TS 38.214). The value interRepetition enables 'Inter-repetition frequency hopping', and the value interSlot enables 'Inter-slot frequency hopping'. If the field is absent, the frequency hopping is not enabled for Type 1 CG.
harq-ProcID-Offset
For operation with shared spectrum channel access configured with cg-RetransmissionTimer-r16, this configures the range of HARQ process IDs which can be used for this configured grant where the UE can select a HARQ process ID within [harq-procID-offset, .., (harq-procID-offset + nrofHARQ-Processes - 1)]. harq-ProcID-Offset-v1730 is only applicable for operation with shared spectrum channel access in FR2-2. If the field harq-ProcID-Offset-v1730 is present, the UE shall ignore the harq-ProcID-Offset-r16. The network does not configure this field for CG-SDT.
harq-ProcID-Offset2
Indicates the offset used in deriving the HARQ process IDs, see clause 5.4.1 of TS 38.321. This field is not configured together with cg-RetransmissionTimer-r16. If the field harq-ProcID-Offset2-v1700 is present, the UE shall ignore the harq-ProcID-Offset2-r16.
mappingPattern
Indicates whether the UE should follow Cyclical mapping pattern or Sequential mapping pattern when two SRS resource sets are configured in srs-ResourceSetToAddModList or srs-ResourceSetToAddModListDCI-0-2 with usage 'codebook' or 'noncodebook' for PUSCH transmission with a Type 1 configured grant and/or a Type 2 configured grant as described in clause 6.1.2.3 of TS 38.214
mcs-Table
Indicates the MCS table the UE shall use for PUSCH without transform precoding. If the field is absent the UE applies the value qam64.
mcs-TableTransformPrecoder
Indicates the MCS table the UE shall use for PUSCH with transform precoding. If the field is absent the UE applies the value qam64.
mcsAndTBS
The modulation order, target code rate and TB size (see clause 6.1.2 of TS 38.214). The NW does not configure the values 28~31 in this version of the specification.
nrofHARQ-Processes
The number of HARQ processes configured. It applies for both Type 1 and Type 2. See clause 5.4.1 of TS 38.321. If the UE is configured with nrofHARQ-Processes-v1700, the UE shall ignore nrofHARQ-Processes (without suffix).
pathlossReferenceIndex
Indicates the reference signal index used as PUSCH pathloss reference (see clause 7.1.1 of S 38.213 [13]). In case of CG-SDT, the UE does not use this field.
pathlossReferenceIndex2
Indicates the reference signal used as PUSCH pathloss reference for the second SRS resource set. When this field is present, pathlossReferenceIndex indicates the reference signal used as PUSCH pathloss reference for the first SRS resource set
p0-PUSCH-Alpha
Index of the P0-PUSCH-AlphaSet to be used for this configuration.
p0-PUSCH-Alpha2
Index of the P0-PUSCH-AlphaSet to be used for second SRS resource set. If this field is present, the p0-PUSCH-Alpha provides index for the P0-PUSCH-AlphaSet to be used for first SRS resource set.
periodicity
Periodicity for UL transmission without UL grant for type 1 and type 2 (see clause 5.8.2 of TS 38.321).
The following periodicities are supported depending on the configured subcarrier spacing [symbols]:
15 kHz: 2, 7, n*14, where n={1, 2, 4, 5, 8, 10, 16, 20, 32, 40, 64, 80, 128, 160, 320, 640}
30 kHz: 2, 7, n*14, where n={1, 2, 4, 5, 8, 10, 16, 20, 32, 40, 64, 80, 128, 160, 256, 320, 640, 1280}
60 kHz with normal CP 2, 7, n*14, where n={1, 2, 4, 5, 8, 10, 16, 20, 32, 40, 64, 80, 128, 160, 256, 320, 512, 640, 1280, 2560}
60 kHz with ECP: 2, 6, n*12, where n={1, 2, 4, 5, 8, 10, 16, 20, 32, 40, 64, 80, 128, 160, 256, 320, 512, 640, 1280, 2560}
120 kHz: 2, 7, n*14, where n={1, 2, 4, 5, 8, 10, 16, 20, 32, 40, 64, 80, 128, 160, 256, 320, 512, 640, 1024, 1280, 2560, 5120} 480 and 960 kHz: n*14, where n={1, 2, 4, 5, 8, 10, 16, 20, 32, 40, 64, 80, 128, 160, 256, 320, 512, \break:10 640, 1024, 1280, 2560, 5120}
In case of SDT, the network does not configure periodicity values less than 5ms.
periodicityExt
This field is used to calculate the periodicity for UL transmission without UL grant for type 1 and type 2 (see clause 5.8.2 of TS 38.321). If this field is present, the field periodicity is ignored.
The following periodicites are supported depending on the configured subcarrier spacing [symbols]:
15 kHz: periodicityExt*14, where periodicityExt has a value between 1 and 640.
30 kHz: periodicityExt*14, where periodicityExt has a value between 1 and 1280.
60 kHz with normal CP: periodicityExt*14, where periodicityExt has a value between 1 and 2560.
60 kHz with ECP: periodicityExt*12, where periodicityExt has a value between 1 and 2560. 120 kHz: periodicityExt*14, where periodicityExt has a value between 1 and 5120.
480 kHz: periodicityExt*14, where periodicityExt has a value between 1 and 20480.
960 kHz: periodicityExt*14, where periodicityExt has a value between 1 and 40960.
In case of SDT, the network does not configure periodicity values less than 5ms.
phy-PriorityIndex
Indicates the PHY priority of CG PUSCH at least for PHY-layer collision handling. Value p0 indicates low priority and value p1 indicates high priority. The network does not configure this for CG-SDT.
powerControlLoopToUse
Closed control loop to apply (see clause 7.1.1 of TS 38.213).
powerControlLoopToUse2
Closed control loop to apply to second SRS resource set (see clause 7.1.1 of TS 38.213). If this field is present, the powerControlLoopToUse applies to the first SRS resource set.
precodingAndNumberOfLayers
Indicates the precoding and number of layers (see clause 7.3.1.1.2 of TS 38.212, and clause 6.1.2.3 of TS 38.214). In case of CG-SDT, network sets this field to 1.
precodingAndNumberOfLayers2
Indicates the precoding and number of layers for the second SRS resource set. When this field is present, precodingAndNumberOfLayers indicated the precoding and number of layers for the first SRS resource set.
pusch-RepTypeIndicator
Indicates whether UE follows the behavior for PUSCH repetition type A or the behavior for PUSCH repetition type B for each Type 1 configured grant configuration. The value pusch-RepTypeA enables the 'PUSCH repetition type A' and the value pusch-RepTypeB enables the 'PUSCH repetition type B' (see clause 6.1.2.3 of TS 38.214,). The value pusch-RepTypeB is not configured simultaneously with cg-nrofPUSCH-InSlot-r16 and cg-nrofSlots-r16. The network does not configure this field if cg-RetransmissionTimer-r16 is configured for CG operation with shared spectrum channel access.
rbg-Size
Selection between configuration 1 and configuration 2 for RBG size for PUSCH. The UE does not apply this field if resourceAllocation is set to resourceAllocationType1. Otherwise, the UE applies the value config1 when the field is absent. Note: rbg-Size is used when the transformPrecoder parameter is disabled.
repK-RV
The redundancy version (RV) sequence to use. See clause 6.1.2 of TS 38.214. The network configures this field if repetitions are used, i.e., if repK is set to n2, n4 or n8. This field is not configured when cg-RetransmissionTimer is configured. Otherwise, the field is absent.
repK
Number of repetitions K, see TS 38.214. If the field repK-v1710 is present, the UE shall ignore the repK (without suffix).
resourceAllocation
Configuration of resource allocation type 0 and resource allocation type 1. For Type 1 UL data transmission without grant, resourceAllocation should be resourceAllocationType0 or resourceAllocationType1.
rrc-ConfiguredUplinkGrant
Configuration for "configured grant" transmission with fully RRC-configured UL grant (Type1). If this field is absent the UE uses UL grant configured by DCI addressed to CS-RNTI (Type2).
sequenceOffsetForRV
Configures the RV offset for the starting RV for the first repetition (first actual repetition in PUSCH repetition Type B) towards the second 'SRS resource set' for PUSCH configured in either srs-ResourceSetToAddModList or srs-ResourceSetToAddModListDCI-0-2 with usage 'codebook' or 'noncodebook'.
srs-ResourceIndicator
Indicates the SRS resource to be used. The network does not configure this for CG-SDT.
srs-ResourceIndicator2
Indicates the SRS resource to be used for the second SRS resource set. When this field is present, the srs-ResourceIndicator is used for the first SRS resource set.
startingFromRV0
This field is used to determine the initial transmission occasion of a transport block for a given RV sequence, see clause 6.1.2.3.1 of TS 38.214. The network does not configure this field if cg-RetransmissionTimer-r16 is configured for CG operation.
timeDomainAllocation, timeDomainAllocation-v1710
Indicates a combination of start symbol and length and PUSCH mapping type, see clause 6.1.2 of TS 38.214, and clause 7.3.1 of TS 38.212.
If the field timeDomainAllocation-v1710 is present, the UE shall ignore timeDomainAllocation field (without suffix).
timeDomainOffset
Offset related to the reference SFN indicated by timeReferenceSFN, see clause 5.8.2 of TS 38.321. timeDomainOffset-r17 is only applicable to 480 kHz and 960 kHz. If timeDomainOffset-r17 is present, the UE shall ignore timeDomainOffset (without suffix).
timeReferenceSFN
Indicates SFN used for determination of the offset of a resource in time domain. The UE uses the closest SFN with the indicated number preceding the reception of the configured grant configuration, see clause 5.8.2 of TS 38.321. If the field timeReferenceSFN is not present, the reference SFN is 0.
transformPrecoder
Enables or disables transform precoding for type1 and type2. If the field is absent, the UE enables or disables transform precoding in accordance with the field msg3-transformPrecoder in RACH-ConfigCommon from rach-ConfigCommon included directly within BWP configuration (i.e., not included in additionalRACH-ConfigList), see clause 6.1.3 of TS 38.214.
uci-OnPUSCH
Selection between and configuration of dynamic and semi-static beta-offset. For Type 1 UL data transmission without grant, uci-OnPUSCH should be set to semiStatic. The network does not configure this for CG-SDT.
CG-COT-Sharing field descriptions
channelAccessPriority
Indicates the Channel Access Priority Class that the gNB can assume when sharing the UE initiated COT (see clause 4.1.3 of TS 37.213).
duration
Indicates the number of DL transmission slots within UE initiated COT (see clause 4.1.3 of TS 37.213).
offset
Indicates the number of DL transmission slots from the end of the slot where CG-UCI is detected after which COT sharing can be used (see clause 4.1.3 of TS 37.213).
CG-StartingOffsets field descriptions
cg-StartingFullBW-InsideCOT
A set of configured grant PUSCH transmission starting offsets which indicates the length of a CP extension of the first symbol that is located before the configured resource when frequency domain resource allocation includes all interlaces in the allocated RB set(s) and the CG PUSCH resource is inside gNB COT (see clause 6.1.2.3 of TS 38.214).
cg-StartingFullBW-OutsideCOT
A set of configured grant PUSCH transmission starting offset indices (see TS 38.211, Table 5.3.1-2) which indicates the length of a CP extension of the first symbol that is located before the configured resource when frequency domain resource allocation includes all interlaces in the allocated RB set(s) and the CG PUSCH resource is outside gNB COT (see clause 6.1.2.3 of TS 38.214).
cg-StartingPartialBW-InsideCOT
A set of configured grant PUSCH transmission starting offset index (see TS 38.211, Table 5.3.1-2) which indicates the length of a CP extension of the first symbol that is located before the configured resource when frequency domain resource allocation does not include all interlaces in the allocated RB set(s) and the CG PUSCH resource is inside gNB COT (see clause 6.1.2.3 of TS 38.214).
cg-StartingPartialBW-OutsideCOT
A set of configured grant PUSCH transmission starting offset index (see TS 38.211, Table 5.3.1-2) which indicates the length of a CP extension of the first symbol that is located before the configured resource when frequency domain resource allocation does not include all interlaces in the allocated RB set(s) and the CG PUSCH resource is outside gNB COT (see clause 6.1.2.3 of TS 38.214).
CG-SDT-Configuration field descriptions
cg-SDT-RetransmissionTimer
Indicates the initial value of the configured grant retransmission timer used for the initial transmission of CG-SDT with CCCH message (see TS 38.321) in multiples of periodicity.
sdt-DMRS-Ports
Indicates the set of DMRS ports for SSB to PUSCH mapping (see TS 38.213). In case of a RedCap-specific initial downlink BWP that is associated with NCD-SSB, the SSB is the NCD-SSB. Otherwise, the SSB is the CD-SSB.
sdt-NrofDMRS-Sequences
Indicates the number of DMRS sequences for SSB to PUSCH mapping (see TS 38.213). In case of a RedCap-specific initial downlink BWP that is associated with NCD-SSB, the SSB is the NCD-SSB. Otherwise, the SSB is the CD-SSB.
sdt-SSB-Subset
Indicates SSB subset for SSB to CG PUSCH mapping within one CG configuration. If this field is absent, UE assumes the SSB set includes all actually transmitted SSBs. In case of a RedCap-specific initial downlink BWP that is associated with NCD-SSB, the SSB is the NCD-SSB. Otherwise, the SSB is the CD-SSB.
sdt-SSB-PerCG-PUSCH
The number of SSBs per CG PUSCH (see TS 38.213). Value one corresponds to 1 SSBs per CG PUSCH, value two corresponds to 2 SSBs per CG PUSCH and so on. In case of a RedCap-specific initial downlink BWP that is associated with NCD-SSB, the SSB is the NCD-SSB. Otherwise, the SSB is the CD-SSB.
sdt-P0-PUSCH
Indicates P0 value for PUSCH for CG SDT in steps of 1dB (see TS 38.213). When this field is configured, the UE ignores the p0-PUSCH-Alpha.
sdt-Alpha
Indicates alpha value for PUSCH for CG SDT. alpha0 indicates value 0 is used alpha04 indicates value 4 is used and so on (see TS 38.213). When this field is configured, the UE ignores the p0-PUSCH-Alpha.
Conditional Presence Explanation
LCH-BasedPrioritizationThis field is optionally present, Need R, if lch-BasedPrioritization is configured in the MAC entity. It is absent otherwise.
RepTypeBThe field is optionally present if pusch-RepTypeIndicator is set to pusch-RepTypeB, Need S, and absent otherwise.
CG-ListThe field is mandatory present when included in configuredGrantConfigToAddModList-r16, otherwise the field is absent.
CG-IndexMACThe field is mandatory present if at least one configured grant is configured by configuredGrantConfigToAddModList-r16 in any BWP of this MAC entity, otherwise it is optionally present, need R.
SRSsetsThis field is mandatory present when UE is configured with two SRS sets configured in either srs-ResourceSetToAddModList or srs-ResourceSetToAddModListDCI-0-2 with usage codebook or non-codebook. Otherwise it is absent, Need R
Up

 –  ConfiguredGrantConfigIndex |R16|p. 554

The IE ConfiguredGrantConfigIndex is used to indicate the index of one of multiple UL Configured Grant configurations in one BWP.
ConfiguredGrantConfigIndex information element
Up

 –  ConfiguredGrantConfigIndexMAC |R16|p. 555

The IE ConfiguredGrantConfigIndexMAC is used to indicate the unique Configured Grant configurations index per MAC entity.
ConfiguredGrantConfigIndexMAC information element
Up

Up   Top   ToC