Tech-invite3GPPspaceIETFspace
21222324252627282931323334353637384‑5x

Content for  TS 38.331  Word version:  18.0.0

Top   Top   Up   Prev   Next
1…   4…   5…   5.2.2.4…   5.3…   5.3.3…   5.3.5…   5.3.5.5…   5.3.5.6…   5.3.5.7…   5.3.5.13…   5.3.5.17…   5.3.6…   5.3.8…   5.3.13…   5.3.14…   5.4…   5.5…   5.5.3…   5.5.4…   5.5.4.15…   5.5.4.23…   5.5.5…   5.5a…   5.7…   5.7.4…   5.7.8…   5.7.12…   5.8…   5.8.9…   5.8.9.2…   5.8.9.8…   5.8.10…   5.8.11…   5.9…   5.10…   6…   6.2.2…   6-2-2-23…   6-2-2-27…   6-2-2-43…   6-2-2-47…   6.3…   6.3.2…   6-3-2-27…   6-3-2-49…   6-3-2-73…   6-3-2-95…   6-3-2-108…   6-3-2-134…   6-3-2-162…   6-3-2-188…   6-3-2-213…   6-3-2-243…   6-3-2-271…   6-3-2-297…   6-3-2-341…   6.3.3…   6-3-3-25…   6-3-3-51…   6.3.4…   6.3.5…   6-3-5-25…   6.3.6…   6.4…   7…   9…   11…   A…   A.4…   B…

 

 –  MeasIdToAddModListp. 800

The IE MeasIdToAddModList concerns a list of measurement identities to add or modify, with for each entry the measId, the associated measObjectId and the associated reportConfigId.
MeasIdToAddModList information element
Up

 –  MeasObjectCLIp. 800

The IE MeasObjectCLI specifies information applicable for SRS-RSRP measurements and/or CLI-RSSI measurements.
MeasObjectCLI information element
CLI-ResourceConfig field descriptions
srs-ResourceConfig
SRS resources to be used for CLI measurements.
rssi-ResourceConfig
CLI-RSSI resources to be used for CLI measurements.
MeasObjectCLI field descriptions
cli-ResourceConfig
SRS and/or CLI-RSSI resource configuration for CLI measurement.
SRS-ResourceConfigCLI field descriptions
refBWP
DL BWP id that is used to derive the reference point of the SRS resource (see clause 6.4.1.4.3 of TS 38.211).
refServCellIndex
The index of the reference serving cell that the refBWP belongs to. If this field is absent, the reference serving cell is PCell.
srs-SCS
Subcarrier spacing for SRS.
Only the following values are applicable depending on the used frequency:
FR1: 15, 30, or 60 kHz
FR2-1: 60 or 120 kHz
FR2-2: 120, 480, or 960 kHz
RSSI-ResourceConfigCLI field descriptions
nrofPRBs
Allowed size of the measurement BW. Only multiples of 4 are allowed. The smallest configurable number is the minimum of 4 and the width of the active DL BWP. If the configured value is larger than the width of the active DL BWP, the UE shall assume that the actual CLI-RSSI resource bandwidth is within the active DL BWP.
nrofSymbols
Within a slot that is configured for CLI-RSSI measurement (see slotConfiguration), the UE measures the RSSI from startPosition to startPosition + nrofSymbols - 1. The configured CLI-RSSI resource does not exceed the slot boundary of the reference SCS. If the SCS of configured DL BWP(s) is larger than the reference SCS, network configures startPosition and nrofSymbols such that the configured CLI-RSSI resource not to exceed the slot boundary corresponding to the configured BWP SCS. If the reference SCS is larger than SCS of configured DL BWP(s), network ensures startPosition and nrofSymbols are integer multiple of reference SCS divided by configured BWP SCS.
refServCellIndex
The index of the reference serving cell. Frequency reference point of the RSSI resource is subcarrier 0 of CRB0 of the reference serving cell. If this field is absent, the reference serving cell is PCell.
rssi-PeriodicityAndOffset
Periodicity and slot offset for this CLI-RSSI resource. All values are in "number of slots". Value sl1 corresponds to a periodicity of 1 slot, value sl2 corresponds to a periodicity of 2 slots, and so on. For each periodicity the corresponding offset is given in number of slots.
rssi-SCS
Reference subcarrier spacing for CLI-RSSI measurement.
Only the following values are applicable depending on the used frequency:
FR1: 15, 30, or 60 kHz
FR2-1: 60 or 120 kHz
FR2-2: 120, 480, or 960 kHz
UE performs CLI-RSSI measurement with the SCS of the active bandwidth part within the configured CLI-RSSI resource in the active BWP regardless of the reference SCS of the measurement resource.
startPosition
OFDM symbol location of the CLI-RSSI resource within a slot.
startPRB
Starting PRB index of the measurement bandwidth. For the case where the reference subcarrier spacing is smaller than subcarrier spacing of active DL BWP(s), network configures startPRB and nrofPRBs are as a multiple of active BW SCS divided by reference SCS.
Up

 –  MeasObjectEUTRAp. 803

The IE MeasObjectEUTRA specifies information applicable for E-UTRA cells.
MeasObjectEUTRA information element
EUTRAN-ExcludedCell field descriptions
cellIndexEUTRA
Entry index in the cell list.
physicalCellIdRange
Physical cell identity or a range of physical cell identities.
EUTRAN-Cell field descriptions
physicalCellId
Physical cell identity of a cell in the cell list.
cellIndividualOffset
Cell individual offset applicable to a specific cell. Value dB-24 corresponds to -24 dB, dB-22 corresponds to -22 dB and so on.
MeasObjectEUTRA field descriptions
allowedMeasBandwidth
The maximum allowed measurement bandwidth on a carrier frequency as defined by the parameter Transmission Bandwidth Configuration "NRB" TS 36.104.
associatedMeasGap
Indicates the associated measurement gap for measuring this EUTRA frequency. If this field is absent, the associated meaurment gap is the gap configured via gapFR1 or gapUE.
carrierFreq
Identifies E-UTRA carrier frequency for which this configuration is valid. Network does not configure more than one MeasObjectEUTRA for the same physical frequency, regardless of the E-ARFCN used to indicate this.
cellsToAddModListEUTRAN
List of cells to add/ modify in the cell list.
cellsToRemoveListEUTRAN
List of cells to remove from the cell list.
eutra-PresenceAntennaPort1
When set to true, the UE may assume that at least two cell-specific antenna ports are used in all neighbouring cells.
eutra-Q-OffsetRange
Used to indicate a cell, or frequency specific offset to be applied when evaluating triggering conditions for measurement reporting. The value is in dB. Value dB-24 corresponds to -24 dB, value dB-22 corresponds to -22 dB and so on.
excludedCellsToAddModListEUTRAN
List of cells to add/ modify in the exclude-list of cells.
excludedCellsToRemoveListEUTRAN
List of cells to remove from the exclude-list of cells.
measSequence
Indicates the recommended sequence for intra/inter-RAT intra/inter-frequency measurement. Value 1 means the corresponding frequency is measured firstly. Value 2 means the corresponding frequency is measured secondly and so on. If more than one frequency is configured with the same value, it means no recommended sequence among these frequencies. If not configured, it means there is no recommended sequence for the corresponding frequency. This field is only configured for NR standalone or if the measObject is associated to the MCG.
widebandRSRQ-Meas
If set to true, the UE shall, when performing RSRQ measurements, use a wider bandwidth in accordance with TS 36.133. The network may set the field to true if the measurement bandwidth indicated by allowedMeasBandwidth is 50 resource blocks or larger; otherwise the network sets this field to false.
Up

 –  MeasObjectIdp. 805

The IE MeasObjectId used to identify a measurement object configuration.
MeasObjectId information element

 –  MeasObjectNRp. 806

The IE MeasObjectNR specifies information applicable for SS/PBCH block(s) intra/inter-frequency measurements and/or CSI-RS intra/inter-frequency measurements.
MeasObjectNR information element
CellsToAddMod field descriptions
cellIndividualOffset
Cell individual offsets applicable to a specific cell.
physCellId
Physical cell identity of a cell in the cell list.
MeasObjectNR field descriptions
absThreshCSI-RS-Consolidation
Absolute threshold for the consolidation of measurement results per CSI-RS resource(s) from L1 filter(s). The field is used for the derivation of cell measurement results as described in clause 5.5.3.3 and the reporting of beam measurement information per CSI-RS resource as described in clause 5.5.5.2.
absThreshSS-BlocksConsolidation
Absolute threshold for the consolidation of measurement results per SS/PBCH block(s) from L1 filter(s). The field is used for the derivation of cell measurement results as described in clause 5.5.3.3 and the reporting of beam measurement information per SS/PBCH block index as described in clause 5.5.5.2.
allowedCellsToAddModList
List of cells to add/modify in the allow-list of cells. It applies only to SSB resources.
allowedCellsToRemoveList
List of cells to remove from the allow-list of cells.
associatedMeasGapSSB
Indicates the associated measurement gap for SSB measuring identified by ssb-ConfigMobility in this measurement object. When multiple MeasObjectNR with the same SSB frequency are configured, the network configures the same measurement gap ID in this field for each MeasObjectNR. If this field is absent, the associated measurement gap is the gap configured via gapFR1, gapFR2, or gapUE.
associatedMeasGapSSB2
Indicates the associated additional measurement gap for SSB measuring identified by ssb-ConfigMobility in this measurement object for NTN deployments. When multiple MeasObjectNR with the same SSB frequency are configured, the network configures the same measurement gap ID in this field for each MeasObjectNR. If this field is absent, the associated measurement gap is the gap indicated by associatedMeasGapSSB.
associatedMeasGapCSIRS
Indicates the associated measurement gap for CSI-RS measuring identified by csi-rs-ResourceConfigMobility in this measurement object. If this field is absent, the associated measurement gap is the gap configured via gapFR1, gapFR2, or gapUE.
associatedMeasGapCSIRS2
Indicates the associated additional measurement gap for CSI-RS measuring identified by csi-rs-ResourceConfigMobility in this measurement object for NTN deployments. If this field is absent, the associated measurement gap is the gap indicated by associatedMeasGapCSIRS. In this release of the specification, this field is not configured for NTN deployments.
cellsToAddModList
List of cells to add/modify in the cell list.
cellsToRemoveList
List of cells to remove from the cell list.
excludedCellsToAddModList
List of cells to add/modify in the exclude-list of cells. It applies only to SSB resources.
excludedCellsToRemoveList
List of cells to remove from the exclude-list of cells.
freqBandIndicatorNR
The frequency band in which the SSB and/or CSI-RS indicated in this MeasObjectNR are located and according to which the UE shall perform the RRM measurements. This field is always provided when the network configures measurements with this MeasObjectNR.
measCyclePSCell
The parameter is used only when the PSCell is configured on the frequency indicated by the measObjectNR and the SCG is deactivated, see TS 38.133. The field may also be configured when the PSCell is not configured on that frequency. The network always configures measCyclePSCell for the measObjectNR associated with the PSCell if bfd-and-RLM is set to true and the SCG is deactivated. Value ms160 corresponds to 160 ms, value ms256 corresponds to 256 ms and so on.
measCycleSCell
The parameter is used only when an SCell is configured on the frequency indicated by the measObjectNR and is in deactivated state, see TS 38.133. gNB configures the parameter whenever an SCell is configured on the frequency indicated by the measObjectNR, but the field may also be signalled when an SCell is not configured. Value sf160 corresponds to 160 sub-frames, value sf256 corresponds to 256 sub-frames and so on.
measSequence
Indicates the recommended sequence for intra/inter-RAT intra/inter-frequency measurement. Value 1 means the corresponding frequency is measured firstly. Value 2 means the corresponding frequency is measured secondly and so on. If more than one frequency is configured with the same value, it means no recommended sequence among these frequencies. If not provided, it means there is no recommended sequence for the corresponding frequency. This field is only configured for NR standalone or if the measObject is associated to the MCG.
nrofCSInrofCSI-RS-ResourcesToAverage
Indicates the maximum number of measurement results per beam based on CSI-RS resources to be averaged. The same value applies for each detected cell associated with this MeasObjectNR.
nrofSS-BlocksToAverage
Indicates the maximum number of measurement results per beam based on SS/PBCH blocks to be averaged. The same value applies for each detected cell associated with this MeasObject.
ntn-NeighbourCellInfo
Includes satellite assistance information of an NTN neighbour cell.
ntn-PolarizationDL
If present, this parameter indicates polarization information for downlink transmission on service link: including Right hand, Left hand circular polarizations (RHCP, LHCP) and Linear polarization.
ntn-PolarizationUL
If present, this parameter indicates polarization information for uplink transmission on service link. If not present and ntn-PolarizationDL is present, UE assumes the same polarization for UL and DL.
offsetMO
Offset values applicable to all measured cells with reference signal(s) indicated in this MeasObjectNR.
quantityConfigIndex
Indicates the n-th element of quantityConfigNR-List provided in MeasConfig.
referenceSignalConfig
RS configuration for SS/PBCH block and CSI-RS.
refFreqCSI-RS
Point A which is used for mapping of CSI-RS to physical resources according to clause 7.4.1.5.3 of TS 38.211.
smtc1
Primary measurement timing configuration. (see clause 5.5.2.10).
smtc2
Secondary measurement timing configuration for SS corresponding to this MeasObjectNR with PCI listed in pci-List. For these SS, the periodicity is indicated by periodicity in smtc2 and the timing offset is equal to the offset indicated in periodicityAndOffset modulo periodicity. periodicity in smtc2 can only be set to a value strictly shorter than the periodicity indicated by periodicityAndOffset in smtc1 (e.g. if periodicityAndOffset indicates sf10, periodicity can only be set of sf5, if periodicityAndOffset indicates sf5, smtc2 cannot be configured).
smtc3list
Measurement timing configuration list for SS corresponding to IAB-MT. This is used for the IAB-node's discovery of other IAB-nodes and the IAB-Donor-DUs.
smtc4list
Measurement timing configuration list for NTN deployments, see clause 5.5.2.10.
ssbFrequency
Indicates the frequency of the SS associated to this MeasObjectNR. For operation with shared spectrum channel access, this field is a k*30 kHz shift from the sync raster where k = 0,1,2, and so on if the reportType within the corresponding ReportConfigNR is set to reportCGI (see clause 7.4.3.1 of TS 38.211). Frequencies are considered to be on the sync raster if they are also identifiable with a GSCN value (see TS 38.101-1, or TS 38.101-5).
ssb-PositionQCL-Common
Indicates the QCL relationship between SS/PBCH blocks for all measured cells as specified in clause 4.1 of TS 38.213.
ssbSubcarrierSpacing
Subcarrier spacing of SSB.
Only the following values are applicable depending on the used frequency:
FR1: 15 or 30 kHz
FR2-1: 120 or 240 kHz
FR2-2: 120, 480, or 960 kHz
t312
The value of timer T312. Value ms0 represents 0 ms, ms50 represents 50 ms and so on.
ReferenceSignalConfig field descriptions
csi-rs-ResourceConfigMobility
CSI-RS resources to be used for CSI-RS based RRM measurements.
ssb-ConfigMobility
SSB configuration for mobility (nominal SSBs, timing configuration).
RMTC-Config field descriptions
measDurationSymbols
Number of consecutive symbols for which the Physical Layer reports samples of RSSI (see clause 5.1.21 of TS 38.215). Value sym1 corresponds to one symbol, sym14or12 corresponds to 14 symbols of the reference numerology for NCP and 12 symbols for ECP, and so on.
If measDurationSymbols-v1700 is signalled, the UE ignores measDurationSymbols-r16.
ref-BWPId
Indicates the reference BWP for the TCI state indicated in tci-StateInfo. Network includes this field if tci-StateInfo is present. This field is only applicable for operation with shared spectrum channel access in FR2-2 and network does not configure this if the UE does not have any serving cells in FR2-2.
ref-SCS-CP
Indicates a reference subcarrier spacing and cyclic prefix to be used for RSSI measurements (see TS 38.215). Value kHz15 corresponds to 15kHz, kHz30 corresponds to 30 kHz, value kHz60-NCP corresponds to 60 kHz using normal cyclic prefix (NCP), and kHz60-ECP corresponds to 60 kHz using extended cyclic prefix (ECP).
If ref-SCS-CP-v1700 is signalled, the UE ignores ref-SCS-CP-r16.
ref-ServCellId
Indicates the FR2-2 reference serving cell index for the TCI state. Network includes this field if tci-StateInfo is present. This field is only applicable for operation with shared spectrum channel access in FR2-2 and network does not configure this if the UE does not have any serving cells in FR2-2.
rmtc-Bandwidth
Indicates the bandwidth for the RSSI measurement (see clause 5.1.21 of TS 38.215).
rmtc-Frequency
Indicates the center frequency of the measured bandwidth for a frequency which operates with shared spectrum channel access (see clause 5.1.21 of TS 38.215).
rmtc-Periodicity
Indicates the RSSI measurement timing configuration (RMTC) periodicity (see clause 5.1.21 of TS 38.215).
rmtc-SubframeOffset
Indicates the RSSI measurement timing configuration (RMTC) subframe offset for this frequency (see clause 5.1.21 of TS 38.215). For inter-frequency measurements, this field is optional present and if it is not configured, the UE chooses a random value as rmtc-SubframeOffset for measDurationSymbols which shall be selected to be between 0 and the configured rmtc-Periodicity with equal probability.
tci-StateId
Indicates the TCI state to be used for RSSI measurements. This field is only applicable for shared spectrum channel access in FR2-2. Network does not configure this if the UE does not have any serving cells in FR2-2 and in such a case, it is up to UE implementation how to determine the spatial domain filter for the inter-frequency RSSI measurement in FR2-2.
SSB-ConfigMobility field descriptions
cca-CellsToAddModList, cca-CellsToRemoveList
Lists of cells to be added or removed from the list of neighbor cells that apply channel access mode procedures for operation with shared spectrum channel access in accordance with clause 4.4 of TS 37.213 for FR2-2.
deriveSSB-IndexFromCell
If this field is set to true, UE assumes SFN and frame boundary alignment across cells on the same frequency carrier as specified in TS 38.133. Hence, if the UE is configured with a serving cell for which (absoluteFrequencySSB, subcarrierSpacing) in ServingCellConfigCommon is equal to (ssbFrequency, ssbSubcarrierSpacing) in this MeasObjectNR, this field indicates whether the UE can utilize the timing of this serving cell to derive the index of SS block transmitted by neighbour cell. Otherwise, this field indicates whether the UE may use the timing of any detected cell on that target frequency to derive the SSB index of all neighbour cells on that frequency.
deriveSSB-IndexFromCellInter
If this field is present, UE assumes SFN and frame boundary alignment between the reference serving cell indicated by ServCellIndex and all neighbour cells in this MeasObjectNR as specified in TS 38.133. This field also indicates that the UE can utilize the timing of the reference serving cell indicated by ServCellIndex to derive the index of SS block transmitted by all inter-frequency neighbour cells on the frequency indicated by the MeasObjectNR. When this field is included, the network should set deriveSSB-IndexFromCell to true.
ssb-ToMeasure
The set of SS blocks to be measured within the SMTC measurement duration. The first/leftmost bit corresponds to SS/PBCH block index 0, the second bit corresponds to SS/PBCH block index 1, and so on. Value 0 in the bitmap indicates that the corresponding SS/PBCH block is not to be measured while value 1 indicates that the corresponding SS/PBCH block is to be measured (see TS 38.215). When the field is not configured the UE measures on all SS blocks. Regardless of the value of this field, SS/PBCH blocks outside of the applicable smtc are not to be measured. See clause 5.1.1 of TS 38.215.
ssb-ToMeasureAltitudeBasedList
List of altitude-dependent ssb-ToMeasure. When the UE is within an altitude range indicated by altitudeRange, it ignores the ssb-ToMeasure (without suffix), and applies the corresponding ssb-ToMeasure-r18 if present, otherwise measures on all SS-blocks if ssb-ToMeasure-r18 is absent. When the UE is outside all the altitude ranges indicated by altitudeRange (if any), ssb-ToMeasure (without suffix) applies.
For each altitude range, altitudeMin indicates the minimum altitude in meters, altitudeMax indicates the maximum altitude in meters relative to sea level, and if included, altitudeHyst indicates hysteresis in meters for determination of the altitude range. I.e., when altitudeHyst is configured for an altitude range, the UE considers itself to have entered the range if altitudeMin ≤ UE altitude ≤ altitudeMax and after entering the range considers itself to be in the range while (altitudeMin - altitudeHyst) ≤ UE altitude ≤ (altitudeMax + altitudeHyst).
For each altitudeRange, if altitudeMin is absent, value minAltitude-r18 is used and if altitudeMax is absent, value maxAltitude-r18 is used.
SSB-PositionQCL-CellsToAddMod field descriptions
physCellId
Physical cell identity of a cell in the cell list.
ssb-PositionQCL
Indicates the QCL relation between SS/PBCH blocks for a specific cell as specified in clause 4.1 of TS 38.213. If provided, the cell specific value overwrites the value signalled by ssb-PositionQCL-Common.
Conditional Presence Explanation
AssociatedGapCSIRSThis field is optionally present, Need R if associatedMeasGapCSIRS is configured, otherwise, it is absent.
AssociatedGapSSBThis field is optionally present, Need R if associatedMeasGapSSB is configured, otherwise, it is absent.
CSI-RSThis field is mandatory present if csi-rs-ResourceConfigMobility is configured, otherwise, it is absent.
IntraFreqConnectedThis field is optionally present, Need R if the UE is configured with a serving cell for which (absoluteFrequencySSB, subcarrierSpacing) in ServingCellConfigCommon is equal to (ssbFrequency, ssbSubcarrierSpacing) in this MeasObjectNR, otherwise, it is absent.
SCGThis field is optionallly present, Need R, in the measConfig associated with the SCG. It is absent in the measConfig associated with the MCG.
ServingCellThis field is optionally present, Need N, if this MeasObject is configured by the serving cell for a conditional reconfiguration with sync. Otherwise, it is absent.
SharedSpectrumThis field is mandatory present if this MeasObject is for a frequency which operates with shared spectrum channel access in FR1. Otherwise, it is absent, Need R.
SharedSpectrum2This field is optionally present if this MeasObject is for a frequency which operates with shared spectrum channel access in FR2-2, Need R. Otherwise, it is absent, Need R.
SSBorAssociatedSSBThis field is mandatory present if ssb-ConfigMobility is configured or associatedSSB is configured in at least one cell. Otherwise, it is absent, Need R.
Up

 –  MeasObjectNR-SLp. 815

The IE MeasObjectNR-SL concerns a measurement object including a list of transmission resource pool(s) for which CBR measurement is performed for NR sidelink communication/discovery.
MeasObjectNR-SL information element
MeasObjectNR-SL field descriptions
sl-Frequency
Indicates the sidelink frequency associated to this MeasObjectNR-SL. The value 1 corresponds to the frequency of first entry in sl-FreqInfoList broadcast in SIB12, the value 2 corresponds to the frequency of first entry in sl-FreqInfoListSizeExt broadcast in SIB12, the value 3 corresponds to the frequency of second entry in sl-FreqInfoListSizeExt broadcast in SIB12 and so on.
Up

 –  MeasObjectRxTxDiffp. 816

The IE MeasObjectRxTxDiff is used to configure the measurement object for UE Rx-Tx time difference measurement.
MeasObjectRxTxDiff information element
MeasObjectRxTxDiff field descriptions
dl-Ref
configures the DL references signals to measure Rx-Tx time difference. prs-Ref-r17 indicates PRS is chosen, and csi-RS-Ref-r17 indicates that CSI-RS for tracking is chosen.
Only one PRS resource set is configured by the network. Only one NZP-CSI-RS-ResourceSet can be configured with pdc-Info-r17 set to true and it is used for UE Rx-Tx time difference measurement. Only reference signals from the PCell of the MCG can be configured by the network.
Up

 –  MeasObjectToAddModListp. 816

The IE MeasObjectToAddModList concerns a list of measurement objects to add or modify.
MeasObjectToAddModList information element
Up

 –  MeasObjectUTRA-FDDp. 817

The IE MeasObjectUTRA-FDD specifies information applicable for inter-RAT UTRA-FDD neighbouring cells.
MeasObjectUTRA-FDD information element
MeasObjectUTRA-FDD field descriptions
carrierFreq
Identifies UTRA-FDD carrier frequency for which this configuration is valid. NR does not configure more than one measurement object for the same physical frequency regardless of the ARFCN used to indicate this.
cellIndexUTRA-FDD
Entry index in the neighbouring cell list.
cellsToAddModList
List of UTRA-FDD cells to add/modify in the neighbouring cell list.
cellsToRemoveList
List of cells to remove from the neighbouring cell list.
utra-FDD-Q-OffsetRange
Used to indicate a frequency specific offset to be applied when evaluating triggering conditions for measurement reporting. The value is in dB.
Up

 –  MeasResultCellListSFTD-NRp. 818

The IE MeasResultCellListSFTD-NR consists of SFN and radio frame boundary difference between the PCell and an NR cell as specified in TS 38.215 and TS 38.133.
MeasResultCellListSFTD-NR information element
MeasResultCellSFTD-NR field descriptions
sfn-OffsetResult
Indicates the SFN difference between the PCell and the NR cell as an integer value according to TS 38.215.
frameBoundaryOffsetResult
Indicates the frame boundary difference between the PCell and the NR cell as an integer value according to TS 38.215.
Up

 –  MeasResultCellListSFTD-EUTRAp. 818

The IE MeasResultCellListSFTD-EUTRA consists of SFN and radio frame boundary difference between the PCell and an E-UTRA PSCell.
MeasResultCellListSFTD-EUTRA information element
MeasResultSFTD-EUTRA field descriptions
eutra-PhysCellId
Identifies the physical cell identity of the E-UTRA cell for which the reporting is being performed.
sfn-OffsetResult
Indicates the SFN difference between the PCell and the E-UTRA cell as an integer value according to TS 38.215.
frameBoundaryOffsetResult
Indicates the frame boundary difference between the PCell and the E-UTRA cell as an integer value according to TS 38.215.
Up

 –  MeasResultsp. 819

The IE MeasResults covers measured results for intra-frequency, inter-frequency, inter-RAT mobility and measured results for NR sidelink communication/discovery.
MeasResults information element
MeasResultEUTRA field descriptions
eutra-PhysCellId
Identifies the physical cell identity of the E-UTRA cell for which the reporting is being performed. The UE reports a value in the range 0..503, other values are reserved.
MeasResultNR field descriptions
averageDelay
Indicates average delay for the packets during the reporting period, as specified in TS 38.314. Value 0 corresponds to 0 millisecond, value 1 corresponds to 0.1 millisecond, value 2 corresponds to 0.2 millisecond, and so on.
cellResults
Cell level measurement results.
choCandidate
This field indicates whether the associated cell is a candidate target cell for conditional handover or conditional PSCell change or addition. This field may be included only in the SuccessHO-Report or SuccessPSCell-Report within UEInformationResponse message.
choConfig
If the associated cell is a candidate target cell for conditional handover, this field indicates the conditional handover execution condition for each measId within condTriggerConfig associated to the cell. This field may be included only in the rlf-report within UEInformationResponse message.
drb-Id
Indicates DRB value for which uplink PDCP delay ratio or value is provided, according to TS 38.314.
firstTriggeredEvent
This field is set to condFirstEvent if the execution condition associated to the first entry of choConfig was fulfilled first in time. This field is set to condSecondEvent if the execution condition associated to the second entry of choConfig was fulfilled first in time. This field may be included in rlf-report within UEInformationResponse message or in SCGFailureInformation message.
locationInfo
Positioning related information and measurements.
physCellId
The physical cell identity of the NR cell for which the reporting is being performed.
resultsSSB-Cell
Cell level measurement results based on SS/PBCH related measurements.
resultsSSB-Indexes
Beam level measurement results based on SS/PBCH related measurements.
resultsCSI-RS-Cell
Cell level measurement results based on CSI-RS related measurements.
resultsCSI-RS-Indexes
Beam level measurement results based on CSI-RS related measurements.
rsIndexResults
Beam level measurement results.
timeBetweenEvents
Indicates the time elapsed between fulfilling the conditional execution conditions included in choConfig. Value in milliseconds. The maximum value 1023 means 1023ms or longer. This field may be included in the reports associated to UEInformationResponse message, e.g., rlf-Report or in the SCGFailureInformation message.
MeasResultUTRA-FDD field descriptions
physCellId
The physical cell identity of the UTRA-FDD cell for which the reporting is being performed.
utra-FDD-EcN0
According to CPICH_Ec/No in TS 25.133 for FDD.
utra-FDD-RSCP
According to CPICH_RSCP in TS 25.133 for FDD.
MeasResults field descriptions
coarseLocationInfo
This field indicates the coarse location information reported by the UE. This field is coded as the Ellipsoid-Point defined in TS 37.355. The first/leftmost bit of the first octet contains the most significant bit. The least significant bits of degreesLatitude and degreesLongitude are set to 0 to meet the accuracy requirement corresponds to a granularity of approximately 2 km.
It is up to UE implementation how many LSBs are set to 0 to meet the accuracy requirement
excessDelay
Indicates the ratio of packets in UL per DRB exceeding the configured delay threshold among the UL PDCP SDUs, according to the UL PDCP Excess Packet Delay per DRB mapping table, as defined in TS 38.314, Table 4.3.1.e-1.
measId
Identifies the measurement identity for which the reporting is being performed.
measQuantityResults
The value sinr is not included when it is used for LogMeasReport-r16.
measResultCellListSFTD-NR
SFTD measurement results between the PCell and the NR neighbour cell(s) in NR standalone.
measResultCLI
CLI measurement results.
measResultEUTRA
Measured results of an E-UTRA cell.
measResultForRSSI
Includes measured RSSI result in dBm (see TS 38.215) and channelOccupancy which is the percentage of samples when the RSSI was above the configured channelOccupancyThreshold for the associated reportConfig.
measResultListEUTRA
List of measured results for the maximum number of reported best cells for an E-UTRA measurement identity.
measResultListNR
List of measured results for the maximum number of reported best cells for an NR measurement identity.
measResultListUTRA-FDD
List of measured results for the maximum number of reported best cells for a UTRA-FDD measurement identity.
measResultNR
Measured results of an NR cell.
measResultServFreqListEUTRA-SCG
Measured results of the E-UTRA SCG serving frequencies: the measurement result of PSCell and each SCell, if any, and of the best neighbouring cell on each E-UTRA SCG serving frequency.
measResultServFreqListNR-SCG
Measured results of the NR SCG serving frequencies: the measurement result of PSCell and each SCell, if any, and of the best neighbouring cell on each NR SCG serving frequency.
measResultServingMOList
Measured results of measured cells with reference signals indicated in the serving cell measurement objects including measurement results of SpCell, configured SCell(s) and best neighbouring cell within measured cells with reference signals indicated in on each serving cell measurement object. If the sending of the MeasurementReport message is triggered by a measurement configured by the field sl-ConfigDedicatedForNR received within an E-UTRA RRCConnectionReconfiguration message (i.e. CBR measurements), this field is not applicable and its contents is ignored by the network.
measResultSFTD-EUTRA
SFTD measurement results between the PCell and the E-UTRA PScell in NE-DC.
measResultSFTD-NR
SFTD measurement results between the PCell and the NR PScell in NR-DC.
measResultsSL
CBR measurements results for NR sidelink communication/discovery.
measResultUTRA-FDD
Measured result of a UTRA-FDD cell.
sl-MeasResultsCandRelay
Measurement result(s) of candiate L2 U2N relay UE(s).
sl-MeasResultServingRelay
Measurement result of serving L2 U2N relay UE.
Up

 –  MeasResult2EUTRAp. 826

The IE MeasResult2EUTRA contains measurements on E-UTRA frequencies.
MeasResult2EUTRA information element
Up

 –  MeasResult2NRp. 826

The IE MeasResult2NR contains measurements on NR frequencies.
MeasResult2NR information element
Up

 –  MeasResultIdleEUTRAp. 827

The IE MeasResultIdleEUTRA covers the E-UTRA measurement results performed in RRC_IDLE and RRC_INACTIVE.
MeasResultIdleEUTRA information element
MeasResultIdleEUTRA field descriptions
carrierFreqEUTRA
Indicates the E-UTRA carrier frequency.
eutra-PhysCellId
Indicates the physical cell identity of an E-UTRA cell.
measIdleResultEUTRA
Idle/inactive measurement results for an E-UTRA cell.
measResultsPerCarrierListIdleEUTRA
List of idle/inactive measured results for the maximum number of reported E-UTRA carriers.
measResultsPerCellListIdleEUTRA
List of idle/inactive measured results for the maximum number of reported best cells for a given E-UTRA carrier.
Up

 –  MeasResultIdleNRp. 828

The IE MeasResultIdleNR covers the NR measurement results performed in RRC_IDLE and RRC_INACTIVE.
MeasResultIdleNR information element
MeasResultIdleNR field descriptions
carrierFreq
Indicates the NR carrier frequency.
measIdleResultNR
Idle/inactive measurement results for an NR cell (optionally including beam level measurements).
measResultServingCell
Measured results of the serving cell (i.e., PCell) from idle/inactive measurements.
measResultsPerCellListIdleNR
List of idle/inactive measured results for the maximum number of reported best cells for a given NR carrier.
resultsSSB-Indexes
Beam level measurement results (indexes and optionally, beam measurements).
Up

 –  MeasResultRxTxTimeDiffp. 829

The IE MeasResultRxTxTimeDiff is used to provide Rx-Tx time difference measurement result.
MeasResultRxTxTimeDiff information element
MeasResultRxTxTimeDiff field descriptions
rxTxTimeDiff-ue
indicates the Rx-Tx Time difference measurement at the UE (see clause 5.1.30 of TS 38.215).
Up

 –  MeasResultSCG-Failurep. 830

The IE MeasResultSCG-Failure is used to provide information regarding failures detected by the UE in (NG)EN-DC and NR-DC.
MeasResultSCG-Failure information element
Up

 –  MeasResultsSLp. 830

The IE MeasResultsSL covers measured results for NR sidelink communication/discovery.
MeasResultsSL information element
MeasResultsSL field descriptions
measResultNR-SL
Include the measured results for NR sidelink communication/discovery.
MeasResultNR-SL field descriptions
measResultListCBR-NR
CBR measurement results for NR sidelink communication/discovery.
sl-poolReportIdentity
The identity of the transmission resource pool which is corresponding to the sl-ResourcePoolID configured in a resource pool for NR sidelink communication/discovery.
Up

 –  MeasSequencep. 831

The IE MeasSequence is used to configure a recommended sequence for intra/inter-RAT intra/inter-frequency measurement.
MeasSequence information element
Up

 –  MeasTriggerQuantityEUTRAp. 831

The IE MeasTriggerQuantityEUTRA is used to configure the trigger quantity and reporting range for E-UTRA measurements. The RSRP, RSRQ and SINR ranges correspond to RSRP-Range, RSRQ-Range and RS-SINR-Range in TS 36.331, respectively.
MeasTriggerQuantityEUTRA information element
Up

 –  MeasWindowConfigp. 832

The IE MeasWindowConfig specifies the effective measurement window configuration for inter-RAT E-UTRA measurement.
MeasWindowConfig information element
MeasWindowConfig field descriptions
windowDuration
Value windowDuration is the measurement window length in ms of effective measurement window. Value ms2 corresponds to 2 ms, value ms5 corresponds to 5 ms, and Value ms5dot5 corresponds to 5.5 ms.
windowOffsetPeriodicity
Indicates the periodicity and offset of effective measurement window. The choice determines the periodicity (periodicityMs40 for 40ms and periodicityMs80 for 80 ms). The field value indicates the offset in ms.
Up

 –  MobilityStateParametersp. 833

The IE MobilityStateParameters contains parameters to determine UE mobility state.
MobilityStateParameters information element
MobilityStateParameters field descriptions
n-CellChangeHigh
The number of cell changes to enter high mobility state. Corresponds to NCR_H in TS 38.304.
n-CellChangeMedium
The number of cell changes to enter medium mobility state. Corresponds to NCR_M in TS 38.304.
t-Evaluation
The duration for evaluating criteria to enter mobility states. Corresponds to TCRmax in TS 38.304. Value in seconds, s30 corresponds to 30 s and so on.
t-HystNormal
The additional duration for evaluating criteria to enter normal mobility state. Corresponds to TCRmaxHyst in TS 38.304. Value in seconds, value s30 corresponds to 30 seconds and so on.
Up

 –  MRB-Identityp. 833

The IE MRB-Identity is used to identify a multicast MRB used by a UE.
MRB-Identity information element

 –  MsgA-ConfigCommonp. 834

The IE MsgA-ConfigCommon is used to configure the PRACH and PUSCH resource for transmission of MsgA in 2-step random access type procedure.
MsgA-ConfigCommon field descriptions
msgA-PUSCH-Config
Configuration of cell-specific MsgA PUSCH parameters which the UE uses for contention-based MsgA PUSCH transmission of this BWP. If the field is not configured for the selected UL BWP, the UE shall use the MsgA PUSCH configuration of initial UL BWP.
rach-ConfigCommonTwoStepRA
Configuration of cell specific random access parameters which the UE uses for contention based and contention free 2-step random access type procedure as well as for 2-step RA type contention based beam failure recovery in this BWP.
Conditional Presence Explanation
InitialBWPConfigThe field is mandatory present when MsgA-ConfigCommon is configured for the initial uplink BWP, or when MsgA-ConfigCommon is configured for a non-initial uplink BWP and MsgA-ConfigCommon is not configured for the initial uplink BWP, otherwise the field is optionally present, Need S.
Up

 –  MsgA-PUSCH-Configp. 834

The IE MsgA-PUSCH-Config is used to specify the PUSCH allocation for MsgA in 2-step random access type procedure.
MsgA-PUSCH-Config information element
MsgA-PUSCH-Config field descriptions
msgA-DataScramblingIndex
Identifier used to initiate data scrambling (c_init) for msgA PUSCH. If the field is absent the UE applies the value Physical cell ID (physCellID).
msgA-DeltaPreamble
Power offset of msgA PUSCH relative to the preamble received target power. Actual value = field value * 2 [dB] (see clause 7.1 of TS 38.213).
msgA-PUSCH-ResourceGroupA
MsgA PUSCH resources that the UE shall use when performing MsgA transmission using preambles group A. If field is not configured for the selected UL BWP, the UE shall use the MsgA PUSCH configuration for group A of initial UL BWP or (e)RedCap-specific initial UL BWP (if configured) for (e)RedCap UEs.
msgA-PUSCH-ResourceGroupB
MsgA PUSCH resources that the UE shall use when performing MsgA transmission using preambles group B.
msgA-TransformPrecoder
Enables or disables the transform precoder for MsgA transmission (see clause 6.1.3 of TS 38.214).
MsgA-PUSCH-Resource field descriptions
guardBandMsgA-PUSCH
PRB-level guard band between FDMed PUSCH occasions (see clause 8.1A of TS 38.213). If interlaced PUSCH is configured, value 0 is applied.
guardPeriodMsgA-PUSCH
Guard period between PUSCH occasions in the unit of symbols (see clause 8.1A of TS 38.213).
frequencyStartMsgA-PUSCH
Offset of lowest PUSCH occasion in frequency domain with respect to PRB 0 (see clause 8.1A of TS 38.213).
interlaceIndexFirstPO-MsgA-PUSCH
Interlace index of the first PUSCH occasion in frequency domain if interlaced PUSCH is configured. For 30kHz SCS only the integers 1, 2, 3, 4, 5 are applicable (see clause 8.1A of TS 38.213).
mappingTypeMsgA-PUSCH
PUSCH mapping type A or B. If the field is absent, the UE shall use the parameter msgA-PUSCH-TimeDomainAllocation (see clause 8.1A of TS 38.213).
msgA-Alpha
Dedicated alpha value for MsgA PUSCH. If the field is absent, the UE shall use the value of msg3-Alpha if configured, else UE applies value 1 (see clause 7.1.1 of TS 38.213).
msgA-DMRS-Config
DMRS configuration for msgA PUSCH (see clause 8.1A of TS 38.213 and clause 6.2.2 of TS 38.214).
msgA-HoppingBits
Value of hopping bits to indicate which frequency offset to be used for second hop. See Table 8.3-1 in TS 38.213.
msgA-IntraSlotFrequencyHopping
Intra-slot frequency hopping per PUSCH occasion (see clause 8.1A of TS 38.213).
msgA-MCS
Indicates the MCS index for msgA PUSCH from the Table 6.1.4.1-1 for DFT-s-OFDM and Table 5.1.3.1-1 for CP-OFDM in TS 38.214.
msgA-PUSCH-TimeDomainAllocation
Indicates a combination of start symbol and length and PUSCH mapping type from the TDRA table (PUSCH-TimeDomainResourceAllocationList if provided in PUSCH-ConfigCommon, or else the default Table 6.1.2.1.1-2 in TS 38.214 is used if pusch-TimeDomainAllocationList is not provided in PUSCH-ConfigCommon). The parameter K2 in the table is not used for msgA PUSCH. The network configures one of msgA-PUSCH-TimeDomainAllocation and startSymbolAndLengthMsgA-PO, but not both. If the field is absent, the UE shall use the value of startSymbolAndLenghtMsgA-PO.
msgA-PUSCH-TimeDomainOffset
A single time offset with respect to the start of each PRACH slot (with at least one valid RO), counted as the number of slots (based on the numerology of active UL BWP). See clause 8.1A of TS 38.213.
nrofDMRS-Sequences
Number of DMRS sequences for MsgA PUSCH for CP-OFDM. In case of single PUSCH configuration or if the DMRS symbols of multiple configurations are not overlapped, if the DMRS resources configured in one PUSCH occasion is no larger than 8 (for len2) or 4 (for len1), then only DMRS port is configured.
nrofInterlacesPerMsgA-PO
Number of consecutive interlaces per PUSCH occasion if interlaced PUSCH is configured. For 30kHz SCS only the integers 1, 2, 3, 4, 5 are applicable (see clause 8.1A of TS 38.213).
nrofMsgA-PO-FDM
The number of msgA PUSCH occasions FDMed in one time instance (see clause 8.1A of TS 38.213).
nrofMsgA-PO-PerSlot
Number of time domain PUSCH occasions in each slot. PUSCH occasions including guard period are contiguous in time domain within a slot (see clause 8.1A of TS 38.213).
nrofPRBs-PerMsgA-PO
Number of PRBs per PUSCH occasion (see clause 8.1A of TS 38.213).
nrofSlotsMsgA-PUSCH
Number of slots (in active UL BWP numerology) containing one or multiple PUSCH occasions, each slot has the same time domain resource allocation (see clause 8.1A of TS 38.213).
startSymbolAndLengthMsgA-PO
An index giving valid combinations of start symbol, length and mapping type as start and length indicator (SLIV) for the first msgA PUSCH occasion, for RRC_CONNECTED UEs in non-initial BWP as described in clause 6.1.2 of TS 38.214. The network configures the field so that the allocation does not cross the slot boundary. The number of occupied symbols excludes the guard period. If the field is absent, the UE shall use the value in msgA-PUSCH-TimeDomainAllocation (see clause 8.1A of TS 38.213). The network configures one of msgA-PUSCH-TimeDomainAllocation and startSymbolAndLengthMsgA-PO, but not both. If the field is absent, the UE shall use the value of msgA-PUSCH-TimeDomainAllocation.
MsgA-DMRS-Config field descriptions
msgA-DMRS-AdditionalPosition
Indicates the position for additional DM-RS. If the field is absent, the UE applies value pos2.
msgA-MaxLength
indicates single-symbol or double-symbol DMRS. If the field is absent, the UE applies value len1.
msgA-PUSCH-DMRS-CDM-Group
1-bit indication of indices of CDM group(s). If the field is absent, then both CDM groups are used.
msgA-PUSCH-NrofPorts
0 indicates 1 port per CDM group, 1 indicates 2 ports per CDM group. If the field is absent then 4 ports per CDM group are used (see clause 8.1A of TS 38.213).
msgA-ScramblingID0
UL DMRS scrambling initialization for CP-OFDM. If the field is absent the UE applies the value Physical cell ID (physCellID).
msgA-ScramblingID1
UL DMRS scrambling initialization for CP-OFDM. If the field is absent the UE applies the value Physical cell ID (physCellID).
Conditional Presence Explanation
FreqHopConfiguredThis field is mandatory present when the field msgA-IntraSlotFrequencyHopping is configured. Otherwise, the field is absent.
GroupBConfiguredThe field is mandatory present if groupB-ConfiguredTwoStepRA is configured in RACH-ConfigCommonTwoStepRA, otherwise the field is absent.
InitialBWPConfigThe field is mandatory present when MsgA-ConfigCommon is configured for the initial uplink BWP, or when MsgA-ConfigCommon is configured for a non-initial uplink BWP and MsgA-ConfigCommon is not configured for the initial uplink BWP, otherwise the field is optionally present, Need S.
Up

 –  MultiFrequencyBandListNRp. 838

The IE MultiFrequencyBandListNR is used to configure a list of one or multiple NR frequency bands.
MultiFrequencyBandListNR information element
Up

 –  MultiFrequencyBandListNR-SIBp. 839

The IE MultiFrequencyBandListNR-SIB indicates the list of frequency bands, for which cell (re-)selection parameters are common, and a list of additionalPmax and additionalSpectrumEmission.
MultiFrequencyBandListNR-SIB information element
NR-MultiBandInfo field descriptions
freqBandIndicatorNR
Provides an NR frequency band number as defined in TS 38.101-1, TS 38.101-2, table 5.2-1, and TS 38.101-5, table 5.2.2-1.
freqBandIndicatorNR-Aerial
Provides an NR frequency band number for aerial UE(s), as defined in TS 38.101-1, TS 38.101-2, table 5.2-1, and TS 38.101-5, table 5.2.2-1.
nr-NS-PmaxList
Provides a list of additionalPmax and additionalSpectrumEmission values. If the field is absent the UE uses value 0 for the additionalSpectrumEmission (see TS 38.101-1 table 6.2.3.1-1A, TS 38.101-2, table 6.2.3.1-2, and TS 38.101-5, table 6.2.3.1-1A). This field is ignored by IAB-MT, the IAB-MT applies output power and emissions requirements, as specified in TS 38.174. If nr-NS-PmaxList-v1760 is present, it shall contain the same number of entries, listed in the same order as in nr-NS-PmaxList (without suffix).
nr-NS-PmaxListAerial
Provides a list of additionalPmax and additionalSpectrumEmission values for aerial UE(s). If the field is absent, the value indicated by the corresponding field within frequencyBandList for the corresponding NR frequency band number applies, if present. Otherwise (i.e. the field is not present for the corresponding NR frequency band number in any of the nr-NS-PmaxList, nr-NS-PmaxList-v1760 or nr-NS-PmaxListAerial), the UE uses value 0 for the additionalSpectrumEmission (see TS 38.101-1 table 6.2.3.1-1A, TS 38.101-2, table 6.2.3.1-2, and TS 38.101-5, table 6.2.3.1-1A). This field is ignored by IAB-MT, the IAB-MT applies output power and emissions requirements, as specified in TS 38.174.
Conditional Presence Explanation
OptULNotSIB2The field is absent for SIB2 and is mandatory present in SIB4 and frequencyInfoDL-SIB. Otherwise, if the field is absent in frequencyInfoUL-SIB in UplinkConfigCommonSIB, the UE will use the frequency band indicated in frequencyInfoDL-SIB in DownlinkConfigCommonSIB.
Up

Up   Top   ToC