SlotFormatCombination field descriptions |
---|
slotFormatCombinationId
This ID is used in the DCI payload to dynamically select this SlotFormatCombination (see clause 11.1.1 of TS 38.213).
|
slotFormats
Slot formats that occur in consecutive slots in time domain order as listed here (see clause 11.1.1 of TS 38.213, and clause 14 of TS 38.213, for IAB-MT).
|
SlotFormatCombinationsPerCell field descriptions |
---|
enableConfiguredUL
If configured, the UE is allowed to transmit uplink signals/channels (SRS, PUCCH, CG-PUSCH) in the set of symbols of the slot when the UE does not detect a DCI format 2_0 providing a slot format for the set of symbols (see TS 38.213, 11.1.1). This field is applicable only if cg-RetransmissionTimer-r16 is configured.
|
positionInDCI
The (starting) position (bit) of the slotFormatCombinationId (SFI-Index) for this serving cell (servingCellId) within the DCI payload (see clause 11.1.1 of TS 38.213).
|
servingCellId
The ID of the serving cell for which the slotFormatCombinations are applicable.
|
slotFormatCombinations
A list with SlotFormatCombinations. Each SlotFormatCombination comprises of one or more SlotFormats (see clause 4.3.2 of TS 38.211). The total number of slotFormats in the slotFormatCombinations list does not exceed 512.
|
subcarrierSpacing2
Reference subcarrier spacing for a Slot Format Combination on an FDD or SUL cell (see clause 11.1.1 of TS 38.213). For FDD, subcarrierSpacing (SFI-scs) is the reference SCS for DL BWP and subcarrierSpacing2 (SFI-scs2) is the reference SCS for UL BWP. For SUL, subcarrierSpacing (SFI-scs) is the reference SCS for non-SUL carrier and subcarrierSpacing2 (SFI-scs2) is the reference SCS for SUL carrier. The network configures a value that is smaller than or equal to any SCS of configured BWPs of the serving cell that the command applies to. And the network configures a value that is smaller than or equal to the SCS of the serving cell which the UE monitors for SFI indications.
|
subcarrierSpacing
Reference subcarrier spacing for this Slot Format Combination. The network configures a value that is smaller than or equal to any SCS of configured BWPs of the serving cell that the command applies to. And the network configures a value that is smaller than or equal to the SCS of the serving cell which the UE monitors for SFI indications (see clause 11.1.1 of TS 38.213).
|
SlotFormatIndicator field descriptions |
---|
availableRB-SetsToAddModList
A list of AvailableRB-SetsPerCell objects (see clause 11.1.1 of TS 38.213).
|
co-DurationsPerCellToAddModList
A list of CO-DurationsPerCell objects. If not configured, the UE uses the slot format indicator (SFI), if available, to determine the channel occupancy duration (see clause 11.1.1 of TS 38.213).
|
co-DurationsPerCellToReleaseList
A list of CO-DurationsPerCell objects to be released. An entry created using co-DurationsPerCellToAddModList-r16 or co-DurationsPerCellToAddModList-r17 can be deleted using co-DurationsPerCellToReleaseList.
|
dci-PayloadSize
Total length of the DCI payload scrambled with SFI-RNTI (see clause 11.1.1 of TS 38.213).
|
sfi-RNTI
RNTI used for SFI on the given cell (see clause 11.1.1 of TS 38.213).
|
slotFormatCombToAddModList
A list of SlotFormatCombinations for the UE's serving cells (see clause 11.1.1 of TS 38.213).
|
switchTriggerToAddModList, switchTriggerToAddModListSizeExt
A list of SearchSpaceSwitchTrigger objects. Each SearchSpaceSwitchTrigger object provides position in DCI of the bit field indicating search space switching flag for a serving cell or, if cellGroupsForSwitchList is configured, group of serving cells (see clause 10.4 of TS 38.213). If cellGroupsForSwitchList is configured, only one of the cells belonging to the same cell group is added/modified, and the configuration applies to all cells belonging to the cellGroupsForSwitchList (see clause 10.4 of TS 38.213). The network configures more than 4 SearchSpaceSwitchTrigger objects only if cellGroupsForSwitchList is not configured. The UE shall consider entries in switchTriggerToAddModList and in switchTriggerToAddModListSizeExt as a single list, i.e. an entry created using switchTriggerToAddModList can be modifed using switchTriggerToAddModListSizeExt and vice-versa.
|
switchTriggerToReleaseModList, switchTriggerToReleaseListSizeExt
A list of SearchSpaceSwitchTriggers to be released. If cellGroupsForSwitchList is configured, the SearchSpaceSwitchTrigger is released for all serving cells belonging to the same CellGroupForSwitch. The UE shall consider entries in switchTriggerToReleaseList and in switchTriggerToReleaseListSizeExt as a single list, i.e. an entry created using switchTriggerToAddModList or switchTriggerToAddModListSizeExt can be deleted using switchTriggerToReleaseList or switchTriggerToReleaseListSizeExt.
|
AvailableRB-SetsPerCell field descriptions |
---|
positionInDCI
The (starting) position of the bits within DCI payload indicating the availability of the RB sets of a serving cell (see clause 11.1.1 of TS 38.213).
|
servingCelIId
The ID of the serving cell for which the configuration is applicable.
|
CO-DurationsPerCell field descriptions |
---|
co-DurationList
A list of Channel Occupancy duration in symbols.
The maximum duration that can be configured for the following SCS:
|
positionInDCI
Position in DCI of the bit field indicating Channel Occupancy duration for UE's serving cells (see clause 11.1.1 of TS 38.213).
|
servingCelIId
The ID of the serving cell for which the configuration is applicable.
|
subcarrierSpacing
Reference subcarrier spacing for the list of Channel Occupancy durations (see clause 11.1.1 of TS 38.213).
|
SearchSpaceSwitchTrigger field descriptions |
---|
positionInDCI
The position of the bit within DCI payload containing a search space switching flag (see clause 11.1.1 of TS 38.213).
|
servingCellId
The ID of the serving cell for which the configuration is applicable or the group of serving cells as indicated by CellGroupsForSwitch-r16 containing this servingCellId.
|
S-NSSAI field descriptions |
---|
sst
Indicates the S-NSSAI consisting of Slice/Service Type, see TS 23.003.
|
sst-SD
Indicates the S-NSSAI consisting of Slice/Service Type and Slice Differentiator, see TS 23.003.
|
SpeedStateScaleFactors field descriptions |
---|
sf-High
The concerned mobility control related parameter is multiplied with this factor if the UE is in High Mobility state as defined in TS 38.304. Value oDot25 corresponds to 0.25, value oDot5 corresponds to 0.5, oDot75 corresponds to 0.75 and so on.
|
sf-Medium
The concerned mobility control related parameter is multiplied with this factor if the UE is in Medium Mobility state as defined in TS 38.304. Value oDot25 corresponds to 0.25, value oDot5 corresponds to 0.5, value oDot75 corresponds to 0.75, and so on.
|
SPS-Config field descriptions |
---|
harq-CodebookID
Indicates the HARQ-ACK codebook index for the corresponding HARQ-ACK codebook for SPS PDSCH and ACK for SPS PDSCH release.
|
harq-ProcID-Offset
Indicates the offset used in deriving the HARQ process IDs, see clause 5.3.1 of TS 38.321.
|
mcs-Table
Indicates the MCS table the UE shall use for DL SPS (see clause 5.1.3.1 of TS 38.214. If present, the UE shall use the MCS table of low-SE 64QAM table indicated in Table 5.1.3.1-3 of TS 38.214. If this field is absent and field mcs-table in PDSCH-Config is set to 'qam256' and the activating DCI is of format 1_1, the UE applies the 256QAM table indicated in Table 5.1.3.1-2 of TS 38.214. If this field is absent and the field mcs-Table-r17 in PDSCH-Config is set to 'qam1024' and the activating DCI is format 1_1, the UE applies the 1024QAM table indicated in Table 5.1.3.1-4 of TS 38.214. Otherwise, the UE applies the non-low-SE 64QAM table indicated in Table 5.1.3.1-1 of TS 38.214.
|
n1PUCCH-AN
HARQ resource for PUCCH for DL SPS. The network configures the resource either as format0 or format1. The actual PUCCH-Resource is configured in PUCCH-Config and referred to by its ID. See clause 9.2.3 of TS 38.213.
|
n1PUCCH-AN-PUCCHsSCell
HARQ resource for PUCCH on PUCCH switching SCell (sSCell) for DL SPS. The network configures the resource either as format 0 or format 1. The actual PUCCH-Resource is configured in PUCCH-Config of the PUCCH sSCell and referred to by its ID. See clause 9.2.3 of TS 38.213.
|
nrofHARQ-Processes
Number of configured HARQ processes for SPS DL (see clause 5.8.1 of TS 38.321). If UE is configured with nrofHARQ-Processes-v1710 UE shall ignore nrofHARQ-Processes (without suffix).
|
pdsch-AggregationFactor
Number of repetitions for SPS PDSCH (see clause 5.1.2.1 of TS 38.214). When the field is absent, the UE applies PDSCH aggregation factor of PDSCH-Config.
|
periodicity
Periodicity for DL SPS (see TS 38.214, and clause 5.8.1 of TS 38.321).
|
periodicityExt
This field is used to calculate the periodicity for DL SPS (see TS 38.214 and see clause 5.8.1 of TS 38.321). If this field is present, the field periodicity is ignored.
The following periodicities are supported depending on the configured subcarrier spacing [ms]:
15 kHz: periodicityExt, where periodicityExt has a value between 1 and 640.
30 kHz: 0.5 x periodicityExt, where periodicityExt has a value between 1 and 1280.
60 kHz with normal CP. 0.25 x periodicityExt, where periodicityExt has a value between 1 and 2560.
60 kHz with ECP: 0.25 x periodicityExt, where periodicityExt has a value between 1 and 2560.
120 kHz: 0.125 x periodicityExt, where periodicityExt has a value between 1 and 5120.
480 kHz: 0.03125 x periodicityExt, where periodicityExt has a value between 1 and 20480.
960 kHz: 0.015625 x periodicityExt, where periodicityExt has a value between 1 and 40960.
periodicityExt-r17 is only applicable for SCS 480 kHz and 960 kHz.
|
sps-ConfigIndex
Indicates the index of one of multiple SPS configurations.
|
sps-HARQ-Deferral
Indicates the maximum number of slots or subslots the transmission of DL SPS HARQ-ACK in a slot or subslot can be deferred (see clause 9.2.5.4 of TS 38.213).
|
Conditional Presence | Explanation |
---|---|
SPS-List | The field is mandatory present when included in sps-ConfigToAddModList-r16 or sps-ConfigMulticastToAddModList-r17, otherwise the field is absent. |
SPS-PUCCH-AN field descriptions |
---|
maxPayloadSize
Indicates the maximum payload size for the corresponding PUCCH resource ID.
|
sps-PUCCH-AN-ResourceID
Indicates the PUCCH resource ID
|
SRS-CC-SetIndex field descriptions |
---|
cc-IndexInOneCC-Set
Indicates the CC index in one CC set for Type A (see TS 38.212, clause 7.3.1, 11.4 of TS 38.213). The network always includes this field when the srs-TPC-PDCCH-Group is set to typeA.
|
cc-SetIndex
Indicates the CC set index for Type A associated (see TS 38.212, clause 7.3.1, 11.4 of TS 38.213). The network always includes this field when the srs-TPC-PDCCH-Group is set to typeA. The network does not configure this field to 3 in this release of specification.
|
SRS-CarrierSwitching field descriptions |
---|
monitoringCells
A set of serving cells for monitoring PDCCH conveying SRS DCI format with CRC scrambled by TPC-SRS-RNTI (see TS 38.212, clause 7.3.1, 11.3 of TS 38.213).
|
srs-SwitchFromServCellIndex
Indicates the serving cell whose UL transmission may be interrupted during SRS transmission on a PUSCH-less SCell. During SRS transmission on a PUSCH-less SCell, the UE may temporarily suspend the UL transmission on a serving cell with PUSCH in the same CG to allow the PUSCH-less SCell to transmit SRS. (see clause 6.2.1.3 of TS 38.214).
|
srs-TPC-PDCCH-Group
Network configures the UE with either typeA-SRS-TPC-PDCCH-Group or typeB-SRS-TPC-PDCCH-Group, if any.
|
typeA
Type A trigger configuration for SRS transmission on a PUSCH-less SCell (see clause 11.4 of TS 38.213). In this release, the network configures at most one entry (the first entry) of typeA, and the first entry corresponds to the serving cell in which the SRS-CarrierSwitching field is configured. SRS carrier switching to SUL carrier is not supported in this version of the specification.
|
typeB
Type B trigger configuration for SRS transmission on a PUSCH-less SCell (see clause 11.4 of TS 38.213).
|
SRS-TPC-PDCCH-Config field descriptions |
---|
srs-CC-SetIndexlist
A list of pairs of [cc-SetIndex; cc-IndexInOneCC-Set] (see TS 38.212, clause 7.3.1, 11.4 of TS 38.213). The network does not configure this field for typeB.
|
SRS-Config field descriptions |
---|
tpc-Accumulation
If the field is absent, UE applies TPC commands via accumulation. If disabled, UE applies the TPC command without accumulation (this applies to SRS when a separate closed loop is configured for SRS) (see clause 7.3 of TS 38.213).
|
SRS-Resource, SRS-PosResource field descriptions |
---|
cyclicShift-n2
Cyclic shift configuration (see clause 6.2.1 of TS 38.214).
|
cyclicShift-n4
Cyclic shift configuration (see clause 6.2.1 of TS 38.214).
|
cyclicShift-n8
Cyclic shift configuration (see clause 6.2.1 of TS 38.214).
|
enableStartRBHopping
When this RRC parameter is configured, start RB location hopping is enabled for partial frequency sounding in different SRS frequency hopping periods for periodic/semi-persistent/aperiodic SRS as described in Clause 6.4.1.4 in TS 38.211.
|
freqHopping
Includes parameters capturing SRS frequency hopping (see clause 6.2.1 of TS 38.214). For CLI SRS-RSRP measurement, the network always configures this field such that b-hop > b-SRS.
|
groupOrSequenceHopping
Parameter(s) for configuring group or sequence hopping (see clause 6.4.1.4.2 of TS 38.211). For CLI SRS-RSRP measurement, the network always configures this parameter to 'neither'.
|
nrofSRS-Ports
Number of ports. For CLI SRS-RSRP measurement, the network always configures this parameter to 'port1'.
|
periodicityAndOffset-p, periodicityAndOffset-p-Ext
Periodicity and slot offset for this SRS resource. All values are in "number of slots". Value sl1 corresponds to a periodicity of 1 slot, value sl2 corresponds to a periodicity of 2 slots, and so on. For each periodicity the corresponding offset is given in number of slots. For periodicity sl1 the offset is 0 slots (see clause 6.2.1 of TS 38.214). For CLI SRS-RSRP measurement, sl1280 and sl2560 cannot be configured. For SRS-PosResource, values sl20480, sl40960 and sl81920 cannot be configured for SCS=15kHz, values sl40960 and sl81920 cannot be configured for SCS=30kHz, and value sl81920 cannot be configured for SCS=60kHz.
When periodicityAndOffset-p-Ext is present, periodicityAndOffset-p shall be ignored by the UE.
|
periodicityAndOffset-sp, periodicityAndOffset-sp-Ext
Periodicity and slot offset for this SRS resource. All values are in "number of slots". Value sl1 corresponds to a periodicity of 1 slot, value sl2 corresponds to a periodicity of 2 slots, and so on. For each periodicity the corresponding offset is given in number of slots. For periodicity sl1 the offset is 0 slots (see clause 6.2.1 of TS 38.214). For SRS-PosResource, values sl20480, sl40960 and sl81920 cannot be configured for SCS=15kHz, values sl40960 and sl81920 cannot be configured for SCS=30kHz, and value sl81920 cannot be configured for SCS=60kHz.
When periodicityAndOffset-sp-Ext is present, periodicityAndOffset-sp shall be ignored by the UE.
|
ptrs-PortIndex
The PTRS port index for this SRS resource for non-codebook based UL MIMO. This is only applicable when the corresponding PTRS-UplinkConfig is set to CP-OFDM. The ptrs-PortIndex configured here must be smaller than the maxNrofPorts configured in the PTRS-UplinkConfig (see clause 6.2.3.1 of TS 38.214). This parameter is not applicable to CLI SRS-RSRP measurement.
|
resourceMapping
OFDM symbol location of the SRS resource within a slot including nrofSymbols (number of OFDM symbols), startPosition (value 0 refers to the last symbol, value 1 refers to the second last symbol, and so on) and repetitionFactor (see clause 6.2.1 of TS 38.214, and clause 6.4.1.4 of TS 38.211). The configured SRS resource does not exceed the slot boundary. If resourceMapping-r16 is signalled, UE shall ignore the resourceMapping (without suffix). If resourceMapping-r17 is signalled, resourceMapping-r16 is not signalled and the UE shall ignore the resourceMapping (without suffix) and only the values of nrofSymbols which are integer multiples of the configured repetitionFactor can be configured. The network can only signal repetitionFactor-v1730 if resourceMapping-r17 is signalled. When repetitionFactor-v1730 is signalled, the UE shall ignore repetitionFactor-r17. For CLI SRS-RSRP measurement, the network always configures nrofSymbols and repetitionFactor to 'n1'.
|
resourceType
Periodicity and offset for semi-persistent and periodic SRS resource, or slot offset for aperiodic SRS resource for positioning (see clause 6.2.1 of TS 38.214). For CLI SRS-RSRP measurement, only 'periodic' is applicable for resourceType.
|
sequenceId
Sequence ID used to initialize pseudo random group and sequence hopping (see clause 6.2.1 of TS 38.214).
|
spatialRelationInfo
Configuration of the spatial relation between a reference RS and the target SRS. Reference RS can be SSB/CSI-RS/SRS (see clause 6.2.1 of TS 38.214). This parameter is not applicable to CLI SRS-RSRP measurement. This field is not configured if unifiedTCI-StateType is configured for the serving cell.
|
spatialRelationInfo-PDC
Configuration of the spatial relation between a reference RS and the target SRS. Reference RS can be SSB/CSI-RS/SRS/DL-PRS-PDC (see clause 6.2.1 of TS 38.214). The field is present in case of resourceType=periodic and usagePDC-r17=true in the SRS-ResourceSet, otherwise the field is absent.
|
spatialRelationInfoPos
Configuration of the spatial relation between a reference RS and the target SRS. Reference RS can be SSB/CSI-RS/SRS/DL-PRS (see clause 6.2.1 of TS 38.214).
If the IE srs-ResourceId-Ext is present, the IE srs-ResourceId in spatialRelationInfoPos represents the index from 0 to 63. Otherwise the IE srs-ResourceId in spatialRelationInfoPos represents the index from 0 to 31.
|
srs-RequestDCI-0-2
Indicate the number of bits for "SRS request"in DCI format 0_2. When the field is absent, then the value of 0 bit for "SRS request" in DCI format 0_2 is applied. If the parameter srs-RequestDCI-0-2 is configured to value 1, 1 bit is used to indicate one of the first two rows of Table 7.3.1.1.2-24 in TS 38.212 for triggered aperiodic SRS resource set. If the value 2 is configured, 2 bits are used to indicate one of the rows of Table 7.3.1.1.2-24 in TS 38.212. When UE is configured with supplementaryUplink, an extra bit (the first bit of the SRS request field) is used for the non-SUL/SUL indication.
|
srs-RequestDCI-1-2
Indicate the number of bits for "SRS request" in DCI format 1_2. When the field is absent, then the value of 0 bit for "SRS request" in DCI format 1_2 is applied. When the UE is configured with supplementaryUplink, an extra bit (the first bit of the SRS request field) is used for the non-SUL/SUL indication (see clause 6.1.1.2 of TS 38.214).
|
srs-ResourceSetToAddModListDCI-0-2
List of SRS resource set to be added or modified for DCI format 0_2 (see clause 7.3.1 of TS 38.212).
|
srs-ResourceSetToReleaseListDCI-0-2
List of SRS resource set to be released for DCI format 0_2 (see clause 7.3.1 of TS 38.212).
|
srs-TCI-State
Configuration of either a UL TCI state or a joint TCI state for the SRS resource. In case of UL TCI-State, refers to the TCI state defined in ul-TCI-StateList in the BWP-UplinkDedicated where the SRS-Config is configured. In case of joint TCI state, refers to a TCI state defined in dl-OrJointTCI-StateList in pdsch-Config of the BWP-DownlinkDedicated and serving cell indicated by cellAndBWP. This field is absent when the SRS resource is in an SRS-ResourceSet configured with followUnifiedTCI-StateSRS-r17 or when the field unifiedTCI-StateType is not configured to the serving cell which the SRS resource is located in.
|
startRBIndexAndFreqScalingFactor
Configures the UE with the startRBIndex and freqScalingFactor for partial frequency sounding as described in clause 6.4.1.4 in TS 38.211. The startRBIndexForFScaling2 gives the startRBIndex when freqScalingFactor is 2 and the startRBIndexForFScaling4 gives the startRBIndex when FreqScalingFactor is 4
|
transmissionComb, transmissionComb-n8
Comb value (2 or 4 or 8) and comb offset (0..combValue-1) (see clause 6.2.1 of TS 38.214).
|
SRS-ResourceSet, SRS-PosResourceSet field descriptions |
---|
alpha
alpha value for SRS power control (see clause 7.3 of TS 38.213). When the field is absent the UE applies the value 1.
|
aperiodicSRS-ResourceTriggerList
An additional list of DCI "code points" upon which the UE shall transmit SRS according to this SRS resource set configuration (see clause 6 of TS 38.214). When the field is not included during a reconfiguration of SRS-ResourceSet of resourceType set to aperiodic, UE maintains this value based on the Need M; that is, this list is not considered as an extension of aperiodicSRS-ResourceTrigger for purpose of applying the general rule for extended list in clause 6.1.3.
|
aperiodicSRS-ResourceTrigger
The DCI "code point" upon which the UE shall transmit SRS according to this SRS resource set configuration (see clause 6 of TS 38.214).
|
associatedCSI-RS
ID of CSI-RS resource associated with this SRS resource set in non-codebook based operation (see clause 6.1.1.2 of TS 38.214).
|
availableSlotOffset
Indicates the number of available slots from slot n+k to the slot where the aperiodic SRS resource set is transmitted, where slot n is the slot with the triggering DCI, and k is the legacy triggering offset (slotOffset, not based on availabel slot) as described in clause 6.2.1 of TS 38.214.
|
csi-RS
ID of CSI-RS resource associated with this SRS resource set. (see clause 6.1.1.2 of TS 38.214).
|
dl-PRS
This field indicates a PRS configuration.
|
followUnifiedTCI-StateSRS
When set to enabled, for SRS resource Set, the UE applies the "indicated" UL only TCI or joint TCI as specified in clause 5.1.5 of TS 38.214. This parameter may be configured for aperiodic SRS for BM or SRS of any time-domain behavior for codebook, non-codebook, and antenna switching.
|
p0
P0 value for SRS power control. The value is in dBm. Only even values (step size 2) are allowed (see clause 7.3 of TS 38.213).
|
pathlossReferenceRS
A reference signal (e.g. a CSI-RS config or a SS block) to be used for SRS path loss estimation (see clause 7.3 of TS 38.213).
|
pathlossReferenceRS-Pos
A reference signal (e.g. a SS block or a DL-PRS config) to be used for SRS path loss estimation (see clause 7.3 of TS 38.213).
|
pathlossReferenceRSList
Multiple candidate pathloss reference RS(s) for SRS power control, where one candidate RS can be mapped to SRS Resource Set via MAC CE (clause 6.1.3.27 in TS 38.321). The network can only configure this field if pathlossReferenceRS is not configured in the same SRS-ResourceSet.
|
resourceType
Time domain behavior of SRS resource configuration, see clause 6.2.1 of TS 38.214. The network configures SRS resources in the same resource set with the same time domain behavior on periodic, aperiodic and semi-persistent SRS. The aperiodic SRS is not applicable for the UE in RRC_INACTIVE.
|
slotOffset
An offset in number of slots between the triggering DCI and the actual transmission of this SRS-ResourceSet. If the field is absent the UE applies no offset (value 0).
|
srs-PowerControlAdjustmentStates
Indicates whether hsrs,c(i) = fc(i,1) or hsrs,c(i) = fc(i,2) (if twoPUSCH-PC-AdjustmentStates are configured) or separate close loop is configured for SRS. This parameter is applicable only for Uls on which UE also transmits PUSCH. If absent or release, the UE applies the value sameAs-Fci1 (see clause 7.3 of TS 38.213).
|
srs-ResourceIdList, srs-PosResourceIdList
The IDs of the SRS-Resources/SRS-PosResource used in this SRS-ResourceSet/SRS-PosResourceSet. If this SRS-ResourceSet is configured with usage set to codebook, the srs-ResourceIdList contains at most 2 entries. If this SRS-ResourceSet is configured with usage set to nonCodebook, the srs-ResourceIdList contains at most 4 entries.
|
srs-ResourceSetId, srs-PosResourceSetId
The ID of this resource set. It is unique in the context of the BWP in which the parent SRS-Config is defined.
|
ssb-IndexServing
Indicates SSB index belonging to a serving cell where the SRS is configured.
|
ssb-NCell
This field indicates a SSB configuration from neighboring cell.
|
usage
Indicates if the SRS resource set is used for beam management, codebook based or non-codebook based transmission or antenna switching. See clause 6.2.1 of TS 38.214. Reconfiguration between codebook based and non-codebook based transmission is not supported.
|
usagePDC
If configured, it indicates that this SRS resource set is used for propagation delay compensation. The field can be present in only one SRS-ResourceSet.
|
SRS-SpatialRelationInfoPos field descriptions |
---|
csi-RS-IndexServing
Indicates CSI-RS index belonging to a serving cell.
|
dl-PRS
This field indicates a PRS configuration.
|
resourceSelection
Indicates whether the configured SRS spatial relation resource is a SRS-Resource or SRS-PosResource.
|
servingCellId
The serving Cell ID of the source SSB, CSI-RS, or SRS for the spatial relation of the target SRS resource. If this field is absent the SSB, the CSI-RS, or the SRS is from the same serving cell where the SRS is configured.
|
ssb-IndexServing
Indicates SSB index belonging to a serving cell.
|
ssb-Ncell
This field indicates a SSB configuration from neighboring cell.
|
SSB-InfoNCell field descriptions |
---|
physicalCellId
This field specifies the physical cell ID of the neighbour cell for which SSB configuration is provided.
|
ssb-IndexNcell
This field specifies the index of the SSB for a neighbour cell. See TS 38.213. If this field is absent, the UE determines the ssb-IndexNcell of the physicalCellId based on its SSB measurement from the cell.
|
ssb-Configuration
This field specifies the full configuration of the SSB. If this field is absent, the UE obtains the configuration for the SSB from nr-SSB-Config received as part of DL-PRS assistance data in LPP, see TS 37.355, by looking up the corresponding SSB configuration using the field physicalCellId.
|
DL-PRS-Info field descriptions |
---|
dl-PRS-ID
This field specifies the UE specific TRP ID (see TS 37.355) for which PRS configuration is provided.
|
dl-PRS-ResourceSetId
This field specifies the PRS-ResourceSet ID of a PRS resourceSet.
|
dl-PRS-ResourceId
This field specifies the PRS-Resource ID of a PRS resource. If this field is absent, the UE determines the dl-PRS-ResourceID based on its PRS measurement from the TRP (see TS 37.355) and DL-PRS Resource Set.
|
SSB-Configuration field descriptions |
---|
halfFrameIndex
Indicates whether SSB is in the first half or the second half of the frame. Value zero indicates the first half and value 1 indicates the second half.
|
integerSubframeOffset
Indicates the subframe boundary offset of the cell in which SSB is transmited.
|
sfn0-Offset
Indiactes the time offset of the SFN0 slot 0 for the cell with respect to SFN0 slot 0 of serving cell.
|
sfn-Offset
Specifies the SFN offset between the cell in which SSB is transmited and serving cell. The offset corresponds to the number of full radio frames counted from the beginning of a radio frame #0 of serving cell to the beginning of the closest subsequent radio frame #0 of the cell in which SSB is transmitted.
|
sfn-SSB-Offset
Indicates the SFN offset of the transmitted SSB relative to the start of the SSB period. Value 0 indicates that the SSB is transmitted in the first system frame, value 1 indicates that SSB is transmitted in the second system frame and so on. The network configures this field according to the field ssb-Periodicity such that the indicated system frame does not exceed the configured SSB periodicity.
|
ssb-Freq
Indicates the frequency of the SSB.
|
ss-PBCH-BlockPower
Average EPRE of the resources elements that carry secondary synchronization signals in dBm that the NW used for SSB transmission, see clause 7 of TS 38.213.
|
ssb-Periodicity
Indicates the periodicity of the SSB. If the field is absent, the UE applies the value ms5. (see clause 4.1 of TS 38.213).
|
ssbSubcarrierSpacing
Subcarrier spacing of SSB.
Only the following values are applicable depending on the used frequency:
FR1: 15 or 30 kHz
FR2-1: 120 or 240 kHz
FR2-2: 120, 480, or 960 kHz
|
Conditional Presence | Explanation |
---|---|
Setup | This field is mandatory present upon configuration of SRS-ResourceSet or SRS-Resource and optionally present, Need M, otherwise. |
NonCodebook | This field is optionally present, Need M, in case of non-codebook based transmission, otherwise the field is absent. |
Pathloss | The field is mandatory present if the IE SSB-InfoNcell is included in pathlossReferenceRS-Pos; otherwise it is optionally present, Need R |
DLorJointTCI-SRS | The field is mandatory present if srs-DLorJointTCI-State is configured, otherwise it is absent Need R. |
SRS-TPC-CommandConfig field descriptions |
---|
fieldTypeFormat2-3
The type of a field within the group DCI with SRS request fields (optional), which indicates how many bits in the field are for SRS request (0 or 2).
Note that for Type A, there is a common SRS request field for all SCells in the set, but each SCell has its own TPC command bits. See clause 7.3.1 of TS 38.212 and clause 11.3 of TS 38.213.
|
startingBitOfFormat2-3
The starting bit position of a block within the group DCI with SRS request fields (optional) and TPC commands. The value 1 of the field corresponds to the first/left most bit of format2-3. The value 2 of the field corresponds to the second bit format2-3, and so on (see clause 7.3.1 of TS 38.212 and clause 11.3 of TS 38.213).
|
startingBitOfFormat2-3SUL
The starting bit position of a block within the group DCI with SRS request fields (optional) and TPC commands for SUL carrier (see clause 7.3.1 of TS 38.212 and clause 11.3 of TS 38.213).
|
SSB-MTC field descriptions |
---|
duration
Duration of the measurement window in which to receive SS/PBCH blocks. It is given in number of subframes (see clause 4.1 of TS 38.213).
|
periodicityAndOffset
Periodicity and offset of the measurement window in which to receive SS/PBCH blocks, see clause 5.5.2.10. Periodicity and offset are given in number of subframes.
|
SSB-MTC2 field descriptions |
---|
pci-List
PCIs that follow this SMTC.
|
SSB-MTC3 field descriptions |
---|
duration
Duration of the measurement window in which to receive SS/PBCH blocks. It is given in number of subframes (see clause 4.1 of TS 38.213).
|
pci-List
PCIs that follow this SMTC, used for IAB-node discovery.
|
periodicityAndOffset
Periodicity and offset of the measurement window in which to receive SS/PBCH blocks, see 5.5.2.10. Periodicity and offset are given in number of subframes.
|
ssb-ToMeasure
The set of SS blocks to be measured within the SMTC measurement duration. The first/leftmost bit corresponds to SS block index 0, the second bit corresponds to SS block index 1, and so on. Value 0 in the bitmap indicates that the corresponding SS block is not to be measured while value 1 indicates that the corresponding SS block is to be measured (see TS 38.215). When the field is not configured the IAB-MT measures on all SS blocks. Regardless of the value of this field, SS blocks outside of the applicable smtc are not to be measured. See clause 5.1.1 of TS 38.215.
|
SSB-MTC4 field descriptions |
---|
pci-List
PCIs that follow this SMTC.
|
offset
Offset of the measurement window in which to receive SS/PBCH blocks, see clause 5.5.2.10. Offset is given in number of subframes.
|
SSB-MTC-AdditionalPCI field descriptions |
---|
additionalPCI
PCI of the additional SSB different from serving cell PCI.
|
periodicity
Periodicity of the SS/PBCH blocks, see clause 5.5.2.10. Periodicity is given in number of subframes.
|
ssb-PositionsInBurst
Indicates the time domain positions of the transmitted SS-blocks in a half frame with SS/PBCH blocks as defined in clause 4.1 of TS 38.213. The first/leftmost bit corresponds to SS/PBCH block index 0, the second bit corresponds to SS/PBCH block index 1, and so on. Value 0 in the bitmap indicates that the corresponding SS/PBCH block is not transmitted while value 1 indicates that the corresponding SS/PBCH block is transmitted.
|
ss-PBCH-BlockPower
Average EPRE of the resources elements that carry secondary synchronization signals in dBm that the NW used for SSB transmission, see clause 7 of TS 38.213.
|
SSB-ToMeasure field descriptions |
---|
longBitmap
Bitmap when maximum number of SS/PBCH blocks per half frame equals to 64 as defined in clause 4.1 of TS 38.213. For operation with shared spectrum channel access in FR2-2, if the k-th bit is set to 1, the UE assumes that one or more SS/PBCH blocks within the SMTC measurement duration with candidate SS/PBCH block indexes corresponding to SS/PBCH block index equal to (k- 1) may be transmitted; if the k-th bit is set to 0, the UE assumes that the corresponding SS/PBCH block(s) are not transmitted.
|
mediumBitmap
Bitmap when maximum number of SS/PBCH blocks per half frame equals to 8 as defined in clause 4.1 of TS 38.213. For operation with shared spectrum channel access, if the k-th bit is set to 1, the UE assumes that one or more SS/PBCH blocks within the SMTC measurement duration with candidate SS/PBCH block indexes corresponding to SS/PBCH block index equal to k - 1 may be transmitted; if the kt-th bit is set to 0, the UE assumes that the corresponding SS/PBCH block(s) are not transmitted. The k-th bit is set to 0, where k > ssb-PositionQCL-Common and the number of actually transmitted SS/PBCH blocks is not larger than the number of 1's in the bitmap. If ssb-PositionQCL is configured with a value smaller than ssb-PositionQCL-Common, only the leftmost K bits (K = ssb-PositionQCL) are applicable for the corresponding cell.
|
shortBitmap
Bitmap when maximum number of SS/PBCH blocks per half frame equals to 4 as defined in clause 4.1 of TS 38.213.
|
SS-RSSI-Measurement field descriptions |
---|
endSymbol
Within a slot that is configured for RSSI measurements (see measurementSlots) the UE measures the RSSI from symbol 0 to symbol endSymbol. This field identifies the entry in Table 5.1.3-1 in TS 38.215, which determines the actual end symbol.
|
measurementSlots
Indicates the slots in which the UE can perform RSSI measurements. The length of the BIT STRING is equal to the number of slots in the configured SMTC window (determined by the duration and by the subcarrierSpacing). The first (left-most / most significant) bit in the bitmap corresponds to the first slot in the SMTC window, the second bit in the bitmap corresponds to the second slot in the SMTC window, and so on. The UE measures in slots for which the corresponding bit in the bitmap is set to 1. In case this field is configured for a SCell with ca-SlotOffset-r16, the bits in the bitmap corresponds to the slots that are fully contained in the SMTC window.
|
TAG field descriptions |
---|
tag-Id
Indicates the TAG of the SpCell or an SCell, see TS 38.321. Uniquely identifies the TAG within the scope of a Cell Group (i.e. MCG or SCG).
|
timeAlignmentTimer
The timeAlignmentTimer for TAG with ID tag-Id, as specified in TS 38.321.
|
TAR-Config field descriptions |
---|
offsetThresholdTA
Offset for TA reporting as specified in TS 38.321. Network only configures this parameter for MCG.
|
timingAdvanceSR
Used to configure whether a Timing Advance report may trigger a Scheduling Request as specified in TS 38.321.
|
TCI-ActivatedConfig field descriptions |
---|
pdcch-TCI
Indicates the TCI state for PDCCH for each configured CORESET of the DL BWP to be activated at SCell activation, to be activated for the PSCell at SCG activation and/or to be used for BFD, RLM and measurements while the SCG is deactivated. The list includes exactly as many entries as CORESETs configured in this BWP, ordered by increasing values of ControlResourceSet-Id, i.e. the first entry indicates the TCI state for the configured CORESET with the lowest ControlResourceset-Id value, the second value indicates the TCI states for the configured CORESET with the second lowest ControlResourceset-Id value, and so on.
|
pdsch-TCI
Indicates TCI states for PDSCH reception at SCell addition/activation or of the PSCell at SCG activation. This field indicates activated TCI state(s) for this BWP ordered by increasing values of TCI-StateId, i.e. the first bit indicates the activation state of the TCI state with the lowest TCI-StateId value, the second value indicates the activation status of the TCI state with the second lowest TCI-State-Id value, and so on. A bit set to 0 indicates that the corresponding TCI state is deactivated, a bit set to 1 indicates that the TCI state is activated.
|
QCL-Info field descriptions |
---|
bwp-Id
The DL BWP which the RS is located in. If the field is absent, the RS is located in the DL BWP in which the TCI-State is applied by the UE.
|
cell
The UE's serving cell in which the referenceSignal is configured. If the field is absent, it applies to the serving cell in which the TCI-State is applied by the UE. The RS can be located on a serving cell other than the serving cell for which the TCI-State is applied by the UE only if the qcl-Type is configured as typeC or typeD. If the referenceSignal is set to csi-rs and unifiedTCI-StateType is configured, either both cell and bwp-Id are present or both cell and bwp-Id are absent. See clause 5.1.5 of TS 38.214.
|
referenceSignal
Reference signal with which quasi-collocation information is provided as specified in clause 5.1.5 of TS 38.214.
|
qcl-Type
QCL type as specified in clause 5.1.5 of TS 38.214.
|
TCI-State field descriptions |
---|
additionalPCI
Indicates the physical cell IDs (PCI) of the SSBs when referenceSignal is configured as SSB for both QCL-Type1 and QCL-Type2. In case the cell is present, the additionalPCI refers to a PCI value configured in the list configured using additionalPCI-ToAddModList in the serving cell indicated by the field cell. Otherwise, it refers to a PCI value configured in a list additionalPCI-ToAddModList configured in the serving cell where the TCI-State is applied by the UE. When this field is present the cell for qcl-Type1 and qcl-Type2 is configured with same value, if present.
|
pathlossReferenceRS-Id
The ID of the reference signal (e.g. a CSI-RS or an SS block) used for PUSCH, PUCCH and SRS path loss estimation. This field refers to an element in the list configured using pathlossReferenceRSToAddModList in the serving cell and UL BWP where the TCI State is applied by the UE.
|
qcl-Type1, qcl-Type2
QCL information for the TCI state as specified in clause 5.1.5 of TS 38.214.
|
tci-StateId
ID number of the TCI state.
|
ul-PowerControl
Configures power control parameters for PUCCH, PUSCH and SRS for this TCI state. The field is present here only if ul-powerControl is not configured in any BWP-Uplink-Dedicated of this serving cell. This field refers to an element in the list configured using uplink-PowerControlToAddModList in the serving cell where the dl-OrJointTCI-StateToAddModList is configured.
|
Conditional Presence | Explanation |
---|---|
CSI-RS-Indicated | This field is mandatory present if csi-rs is included and unifiedTCI-StateType is not configured. This field is optionally present, Need R, if csi-rs is included and unifiedTCI-StateType is configured. Otherwise, it is absent, Need R. |
JointTCI | This field is optionally present, Need R, if this serving cell is configured with unifiedTCI-StateType set to 'joint'. It is absent, Need R, otherwise. |
JointTCI1 | This field is mandatory present, if this serving cell is configured with unifiedTCI-StateType set to 'joint'. It is absent, Need R, otherwise. |
TCI-UL-State field descriptions |
---|
additionalPCI
Indicates the physical cell IDs (PCI) of the SSBs when referenceSignal is configured as SSB. In case the servingCellId is present, the additionalPCI refers to a PCI value configured in the list configured using additionalPCI-ToAddModList in the serving cell indicated by the field servingCellId. Otherwise, it refers to a PCI value configured in the list configured using additionalPCI-ToAddModList in the serving cell where the ul-TCI-StateList is applied by the UE.
|
bwp-Id
The DL BWP which the CSI-RS is located in or UL BWP where the SRS is located in.
|
servingCellId
The UE's serving cell in which the referenceSignal is configured. If the field is absent, it applies to the serving cell in which the TCI-UL-State is applied by the UE.
|
pathlossReferenceRS-Id
The ID of the reference Signal (e.g. a CSI-RS or a SS block) used for PUSCH, PUCCH and SRS path loss estimation. This field refers to an element in the list configured using pathlossReferenceRSToAddModList in the serving cell and UL BWP where the UL TCI State is applied by the UE.
|
ul-powerControl
Configures power control parameters for PUCCH, PUSCH and SRS for this TCI state. The field is present here only if ul-powerControl is not configured in any BWP-Uplink-Dedicated of this serving cell. This field refers to an element in the list configured using uplink-PowerControlToAddModList in the serving cell where the ul-TCI-ToAddModList is configured.
|
Conditional Presence | Explanation |
---|---|
CSI-RSorSRS-Indicated | This field is mandatory present if referenceSignal is set to csi-RS-index or to srs, absent otherwise |
Mandatory | The field is mandatory present. |