Tech-invite3GPPspaceIETFspace
21222324252627282931323334353637384‑5x

Content for  ETSI TS 102 221   PDF version:  18.2.0

Top   Top   Up   Prev   Next
0…   4…   5…   6…   7…   7.2.3…   7.3…   7.3.2…   7.4…   8…   9…   10…   10.2…   11…   11.1.2…   11.1.9…   11.1.14…   11.1.19…   11.1.20…   11.1.21…   11.2…   11.3…   12…   13…   14…   15   A   B   C…   D   E…   F…   G…   H…   I   J…   K…   L…   M…   N…   O…

 

F  Example of contents of EFARR '2F06'p. 174

F.1  Sample content of the EFARRp. 174

This clause contains an example of the contents of EFARR '2F06'.
ARR
Re­cord
Appli
cable
Access
Con­di­tion
AM_DO LEN Va­lue SC_DO
CRT Tag
Se­cu­ri­ty
Con­di­tion
Len Value
Key Ref
Tag
Len Value Usa­ge
Qua­li­fier
Tag
Len Va­lue
01EFREAD
UPDATE/
DE-ACTIVATE/
ACTIVATE
'80'
'80'
'01'
'01'
'01'
'1A'
'90'
'A4'
ALW
Level 5
'00'
'06'
'83''01''0X''95''01''YY'
02EFREAD
DEACTIVATE/
ACTIVATE
'80'
'80'
'01'
'01'
'01'
'18'
'90'
'A4'
ALW
Level 5
'00'
'06'
'83''01''0X''95''01''YY'
03EFREAD
UPDATE
DEACTIVATE/
ACTIVATE
'80'
'80'
'80'
'01'
'01'
'01'
'01'
'02'
'18'
'90'
'A4'
'A4'
ALW
PIN
Level 5
'00'
'06'
'06'
'83'
'83'
'01'
'01'
'01'
'0X'
'95'
'95'
'01'
'01'
'01'
'YY'
The value X in Table F.1 is according to level 5 in Table 9.3. The value 'YY' in Table F.1 is in accordance with ISO/IEC 7816-4 [12].
As an example, those records could be used as follows: the first record of EFARR can be the access rule of EFDIR, the second record of EFARR can be the access rule of EFICCID, the third record of EFARR can be the access rule of EFPL.
Up

Up   Top   ToC