Tech-invite3GPPspaceIETFspace
21222324252627282931323334353637384‑5x

Content for  TS 28.310  Word version:  18.0.0

Top   Top   Up   Prev   Next
1…   4…   5…   6…   6.2…   A…

 

6  Solutions for energy efficiencyp. 19

6.1  Solutions for assessment of mobile network data energy efficiencyp. 19

6.1.1  Energy efficiency of NG-RAN |R17|p. 19

Assessment of NG-RAN data EE is based on the high-level mobile network data EE KPI defined in clause 3.1 and clause 5.3 of ETSI ES 203 228 [2]
TS 28.310 formula: high-level mobile network data EE KPI
For different gNB scenarios, the two following performance measurements may be used as the DVMN:
  • For split-gNBs scenario:
    1. DL PDCP SDU Data Volume per interface (cf. clause 5.1.3.6.2.3 of TS 28.552): This measurement provides the Data Volume (amount of PDCP SDU bits) in the downlink delivered from GNB-CU-UP to GNB-DU (F1-U interface), to external gNB-CU-UP (Xn-U interface) and to external eNB (X2-U interface). The measurement is calculated per QoS level (mapped 5QI or QCI in NR option 3) and per S-NSSAI and per PLMN ID, and reported per Interface (F1-U, Xn-U, X2-U);
    2. UL PDCP SDU Data Volume per interface (cf. clause 5.1.3.6.2.4 of TS 28.552): This measurement provides the Data Volume (amount of PDCP SDU bits) in the uplink delivered to GNB-CU-UP from GNB-DU (F1-U interface), from external gNB-CU-UP (Xn-U interface) and from external eNB (X2-U interface). The measurement is calculated per QoS level (mapped 5QI or QCI in NR option 3) and per S-NSSAI and per PLMN ID, and reported per Interface (F1-U, Xn-U, X2-U);
  • For non-split gNBs scenario:
    1. DL Cell PDCP SDU Data Volume (cf. clause 5.1.2.1.1.1 of TS 28.552): This measurement provides the Data Volume (amount of PDCP SDU bits) in the downlink delivered to PDCP layer. The measurement is calculated per PLMN ID and per QoS level (mapped 5QI) and per S-NSSAI;
    2. UL Cell PDCP SDU Data Volume (cf. clause 5.1.2.1.2.1 of TS 28.552): This measurement provides the Data Volume (amount of PDCP SDU bits) in the uplink delivered from PDCP layer to higher layers. The measurement is calculated per PLMN ID and per QoS level (mapped 5QI) and per S-NSSAI;
The following PEE (Power, Energy and Environmental) measurement may be used as the ECMN:
Up

6.1.2  Energy efficiency of network slices |R17|p. 20

6.1.2.1  Introductionp. 20

Assessment of the energy efficiency of 5G network slices is based on KPIs defined in clause 6.7.2 of TS 28.554.

6.1.2.2  Generic Network Slice Energy Efficiency (EE) KPIp. 20

The Generic network slice EE KPI is defined as:
TS 28.310 formula: Generic network slice EE KPI
where 'Performance of network slice' (Pns) is defined per type of network slice.

6.1.2.3  Energy efficiency of eMBB network slicep. 20

This KPI is obtained by the sum of UL and DL data volumes at N3 interface(s) of the network slice, divided by the energy consumption of the network slice. The unit of this KPI is bit/J.
TS 28.310 formula: Energy efficiency of eMBB network slice KPI
The following measurements are used:
  • GTP.InDataOctN3UPF.SNSSAI: Number of octets of incoming GTP data packets on the N3 interface, from (R)AN to UPF, where SNSSAI identifies the S-NSSAI, as defined in clause 5.4.1.3 of TS 28.552;
  • GTP.OutDataOctN3UPF.SNSSAI: Number of octets of outgoing GTP data packets on the N3 interface, from (R)AN to UPF, where SNSSAI identifies the S-NSSAI, as defined in clause 5.4.1.4 of TS 28.552.
Up

6.1.2.4  Energy efficiency of URLLC network slicep. 21

6.1.2.4.1  Introductionp. 21
This KPI is defined with two variants.
6.1.2.4.2  Based on latency of the network slicep. 21
This KPI is obtained by the inverse of the average end-to-end User Plane (UP) latency of the network slice divided by the energy consumption of the network slice. The unit of this KPI is (0.1ms * J)-1.
In this KPI variant, latency is the only factor considered for evaluating the performance of network slice, i.e. the performance of network slice (Pns) for URLLC type of network slice is the inverse of the end-to-end User Plane (UP) latency of the network slice.
TS 28.310 formula: KPI based on latency of the network slice
Where Network slice mean latency is defined as:
Network slice mean latency = DelayE2EUlNs + DelayE2EDlNs
The following KPIs are used to calculate Network slice mean latency:
  • DelayE2EUlNs: Average e2e uplink delay for a network slice, defined in clause 6.3.1.8.1 of TS 28.554 as the average e2e UL packet delay between the PSA UPF and the UE for a network slice;
  • DelayE2EDlNs: Average e2e downlink delay for a network slice, defined in clause 6.3.1.8.2 of TS 28.554 as the average e2e DL packet delay between the PSA UPF and the UE for a network slice.
Up
6.1.2.4.3  Based on both latency and Data Volume (DV) of the network slicep. 21
This KPI is obtained by the product of the sum of UL and DL traffic data volumes at N3 interface(s) of the network slice multiplied by the inverse of the end-to-end User Plane (UP) latency of the network slice, divided by the energy consumption of the network slice. The unit of this KPI is bit/(0.1ms*J).
In this KPI variant, data volume and latency are two factors considered for evaluating the performance of network slice, i.e. the performance of network slice (Pns) for URLLC type of network slice is the sum of UL and DL traffic data volumes at N3 interface(s) multiplied by the inverse of the end-to-end User Plane (UP) latency of the network slice. This solution is applicable for the case of URLLC network slice is deployed and operators want to evaluate the slice EE KPI for different periods of time such as busy time slots (more DV) and idle time slots (less DV).
TS 28.310 formula: KPI based on both latency and Data Volume (DV) of the network slice
The following measurements, defined in TS 28.552, are used to calculate the sum of UL and DL traffic data volumes at N3 interface(s) of the network slice:
  • GTP.InDataOctN3UPF.SNSSAI: Number of octets of incoming GTP data packets on the N3 interface, from (R)AN to UPF), where SNSSAI identifies the S-NSSAI, as defined in clause 5.4.1.3 of TS 28.552;
  • GTP.OutDataOctN3UPF.SNSSAI: Number of octets of outgoing GTP data packets on the N3 interface, from (R)AN to UPF), where SNSSAI identifies the S-NSSAI, as defined in clause 5.4.1.4 of TS 28.552.
The following KPIs, defined in TS 28.554, are used to calculate the latency of the network slice:
  • DelayE2EUlNs: Average e2e uplink delay for a network slice, defined in clause 6.3.1.8.1 of TS 28.554 as the average e2e UL packet delay between the PSA UPF and the UE for a network slice;
  • DelayE2EDlNs: Average e2e downlink delay for a network slice, defined in clause 6.3.1.8.2 of TS 28.554 as the average e2e DL packet delay between the PSA UPF and the UE for a network slice.
Up

6.1.2.5  Energy efficiency of MIoT network slicep. 22

6.1.2.5.1  Introductionp. 22
This KPI is defined with two variants.
6.1.2.5.2  Based on the number of registered subscribers of the network slicep. 22
This KPI is obtained by the mean number of active UEs of the network slice divided by the energy consumption of the network slice. The unit of this KPI is UE/J.
TS 28.310 formula: KPI based on the number of registered subscribers of the network slice
The following measurement is used:
  • RM.RegisteredSubNbrMax.SNSSAI: maximum number of registered state subscribers per AMF, where SNSSAI identifies the S-NSSAI, as defined in clause 5.2.1.2 of TS 28.552.
Up
6.1.2.5.3  Based on the number of active UEs in the network slicep. 22
This KPI is obtained by the mean number of active UEs of the network slice divided by the energy consumption of the network slice. The unit of this KPI is UE/J.
TS 28.310 formula: KPI based on the number of active UEs in the network slice
The following measurements are used:
Up

Up   Top   ToC