Tech-invite3GPPspaceIETFspace
21222324252627282931323334353637384‑5x

Content for  TS 26.131  Word version:  18.0.0

Top   Top   Up   Prev   Next
0…   5…   5.4…   5.4.3…   5.4.5…   5.4.7…   5.5…   5.8…   5.12…   6…   6.4…   6.4.3…   6.4.5…   6.4.7…   6.5…   6.8…   6.11…   6.12…   7…   7.4…   7.5…   7.8…   7.11…   7.12…   8…   8.4…   8.5…   8.8…   8.11…   8.12…

 

6.4.5  Hand-held hands-free UE sendingp. 43

The sending sensitivity frequency response from the MRP to the SS audio output (digital output of the reference speech decoder of the SS) shall be as follows:
The sending sensitivity frequency response shall be within the mask which can be drawn with straight lines between the breaking points in Table 13 on a logarithmic (frequency) - linear (dB sensitivity) scale.
Frequency (Hz) Upper limit (dB) Lower limit (dB)
1000
2005-5
5 0005-5
6 3005-10
8 0005
NOTE:
All sensitivity values are expressed in dB on an arbitrary scale.
Copy of original 3GPP image for 3GPP TS 26.131, Fig. 13: Hand-held hands-free sending sensitivity/frequency mask
Up
Compliance shall be checked by the relevant test described in TS 26.132.

6.4.6  Hand-held hands-free UE receivingp. 43

The receiving sensitivity frequency response from the SS audio input (analogue or digital input of the reference speech encoder of the SS) to the free-field shall be as follows:
The receiving sensitivity frequency response shall be within the mask which can be drawn with straight lines between the breaking points in Table 14 on a logarithmic (frequency) - linear (dB sensitivity) scale.
Frequency (Hz) Upper limit (dB) Lower limit (dB)
3156
6306-12
8006-6
4 0006-6
6 3006-12
8 0006
NOTE:
All sensitivity values are expressed in dB on an arbitrary scale.
Copy of original 3GPP image for 3GPP TS 26.131, Fig. 14: Hand-held hands-free receiving sensitivity/frequency mask
Up
It is recommended as a performance requirement that the receiving sensitivity frequency response be within the mask which can be drawn with straight lines between the breaking points in Table 14a on a logarithmic (frequency) - linear (dB sensitivity) scale.
Frequency (Hz) Upper limit (dB) Lower limit (dB)
3156
4006-12
5006-6
4 0006-6
6 3006-12
8 0006
NOTE:
All sensitivity values are expressed in dB on an arbitrary scale
Copy of original 3GPP image for 3GPP TS 26.131, Fig. 14a: Performance objective for hand-held hands-free receiving sensitivity/frequency mask
Up
Compliance shall be checked by the relevant test described in TS 26.132.

Up   Top   ToC