Tech-invite3GPPspaceIETFspace
21222324252627282931323334353637384‑5x
Top   in Index   Prev   Next

TS 29.283
MCPTT – Diameter Data Management Applications

V19.0.0 (PDF)  2025/09  41 p.
V18.0.0  2024/03  41 p.
V17.1.0  2022/12  41 p.
V16.1.0  2022/12  41 p.
V15.2.0  2022/12  41 p.
V14.5.0  2022/12  42 p.
V13.5.0  2017/09  37 p.
Rapporteur:
Mr. Morand, Lionel
Orange

full Table of Contents for  TS 29.283  Word version:  19.0.0

each clause number in 'red' refers to the equivalent title in the Partial Content
Here   Top
1Scope  p. 7
2References  p. 7
3Definitions, symbols and abbreviations  p. 8
3.1Definitions  p. 8
3.2Abbreviations  p. 8
4Main Concept  p. 8
4.1Introduction  p. 8
5MC Service General Architecture  p. 9
5.1Introduction  p. 9
5.2Functional requirements of network entities  p. 9
5.2.1Functional Requirements of the MC Service Server  p. 9
5.2.2Functional Requirements of the Configuration Management Server  p. 9
5.2.3Functional requirements of MCPTT User Database  p. 9
5.3Functional classification of MC Service Server to MC Service User Database related interface procedures  p. 10
5.4Functional classification of CSC-13 interface procedures  p. 10
6Procedure Descriptions for MC Services  p. 11
6.1Introduction  p. 11
6.2MC Service User data handling procedures  p. 11
6.2.1Data Pull  p. 11
6.2.1.1General  p. 11
6.2.1.2Detailed behaviour of the requesting entity  p. 12
6.2.1.3Detailed behaviour of the MC Service User Database  p. 12
6.2.2Data Update  p. 13
6.2.2.1General  p. 13
6.2.2.2Detailed behaviour of the Configuration Management Server  p. 14
6.2.2.3Detailed behaviour of the MC Service User Database  p. 15
6.2.3Data Notification  p. 16
6.2.3.1General  p. 16
6.2.3.2Detailed behaviour of the MCPTT User Database  p. 17
6.2.3.3Detailed behaviour of the receiving entity  p. 17
6.3Requesting entity permissions list  p. 18
6.3.1General  p. 18
7Protocol Specification and Implementation for MC Service  p. 19
7.1General  p. 19
7.1.1Use of Diameter base protocol  p. 19
7.1.2Securing Diameter Messages  p. 19
7.1.3Accounting functionality  p. 19
7.1.4Use of sessions  p. 20
7.1.5Transport protocol  p. 20
7.1.6Routing considerations  p. 20
7.1.7Advertising Application Support  p. 21
7.1.8Diameter Application Identifier  p. 21
7.1.9Use of the Supported-Features AVP  p. 21
7.1.10MC Service ID to MC Service User Database resolution  p. 21
7.2Commands  p. 23
7.2.1Introduction  p. 23
7.2.2Command-Code values  p. 23
7.2.3Data-Pull-Request (DPR) Command  p. 23
7.2.4Data-Pull-Answer (DPA) Command  p. 24
7.2.5Data-Update-Request (DUR) Command  p. 24
7.2.6Data-Update-Answer (DUA) Command  p. 24
7.2.7Notification-Data-Request (PDR) Command  p. 25
7.2.8Notification-Data-Answer (PDA) Command  p. 25
7.3AVPs  p. 26
7.3.1General  p. 26
7.3.2MCPTT-ID  p. 27
7.3.3Data-Identification  p. 27
7.3.4DRMP  p. 27
7.3.5OC-OLR  p. 27
7.3.6OC-Supported-Features  p. 27
7.3.7User-Data  p. 27
7.3.8User-Identifier  p. 28
7.3.9Feature-List-ID AVP  p. 28
7.3.10Feature-List AVP  p. 28
7.3.11Data-Identification-Prefix  p. 28
7.3.12Data-Identification-Flags  p. 28
7.3.13DPR-Flags  p. 29
7.3.14DPA-Flags  p. 29
7.3.15DUR-Flags  p. 29
7.3.16DUA-Flags  p. 29
7.3.17NDR-Flags  p. 30
7.3.18NDA-Flags  p. 30
7.3.19User-Data-Id  p. 30
7.3.20MC-Service-User-Profile-Data  p. 30
7.3.21Sequence-Number  p. 31
7.3.22Data  p. 31
7.3.23Load |R14|p. 31
7.3.24MCVideo-ID |R14|p. 31
7.3.25MCData-ID |R14|p. 31
7.4Result-Code and Experimental-Result-Code Values  p. 31
7.4.1Introduction  p. 31
7.4.2Success  p. 31
7.4.2.1General  p. 31
7.4.3Permanent Failures  p. 31
7.4.3.1General  p. 31
7.4.3.2DIAMETER_ERROR_USER_UNKNOWN (5001)  p. 32
7.4.3.3DIAMETER_ERROR_USER_DATA_NOT_RECOGNIZED (5100)  p. 32
7.4.3.4DIAMETER_ERROR_OPERATION_NOT_ALLOWED (5101)  p. 32
7.4.3.5DIAMETER_ERROR_USER_DATA_CANNOT_BE_READ (5102)  p. 32
7.4.3.6DIAMETER_ERROR_USER_DATA_CANNOT_BE_MODIFIED (5103)  p. 32
7.4.3.7DIAMETER_ERROR_USER_DATA_CANNOT_BE_NOTIFIED (5104)  p. 32
7.4.3.8DIAMETER_ERROR_TOO_MUCH_DATA (5008)  p. 32
7.4.3.9DIAMETER_ERROR_DATA OUT_OF_SYNC (5105)  p. 32
7.4.3.10DIAMETER_ERROR_FEATURE_UNSUPPORTED (5011)  p. 32
7.4.3.11DIAMETER_ERROR_NO_SUBSCRIPTION_TO_DATA (5107) |R14|p. 32
7.4.3.12DIAMETER_ERROR_ UNKNOWN _DATA (5670)  p. 32
7.4.3.13DIAMETER_ERROR_REQUIRED_KEY_NOT_PROVIDED (5671)  p. 32
7.4.4Transient Failures  p. 33
7.4.4.1General  p. 33
7.4.4.2DIAMETER_USER_DATA_NOT_AVAILABLE (4100) |R14|p. 33
7.4.4.3DIAMETER_PRIOR_UPDATE_IN_PROGRESS (4101) |R14|p. 33
A(Normative)  Diameter overload control mechanism  p. 34
A.1General  p. 34
A.2MC Service User Database behaviour  p. 34
A.3MC Service Server and Configuration Management Server behaviour  p. 34
BDiameter overload node behaviour  p. 35
B.1Message prioritization  p. 35
C(Normative)  Diameter message priority mechanism  p. 36
C.1General  p. 36
C.2MCPTT-2, MCVideo-2, MCData-2 and CSC-13 interfaces  p. 36
C.2.1General  p. 36
C.2.2MC Service Server and Configuration Management Server behaviour  p. 36
C.2.3MC Service User Database behaviour  p. 37
D(Normative)  Diameter load control mechanism |R14|p. 37
D.1General  p. 37
D.2MC Service User Database behaviour  p. 37
D.3MC Service Server and Configuration Management Server behaviour  p. 38
$Change History  p. 39

Up   Top