Tech-invite3GPPspaceIETFspace
21222324252627282931323334353637384‑5x

Content for  TS 28.201  Word version:  17.0.0

Top   Top   Up   Prev   None
1…   4…   5…   6…

 

6  Definition of charging informationp. 17

6.1  Data description for network slice performance and analytics chargingp. 17

6.1.1  Message contentsp. 17

6.1.1.1  Generalp. 17

The Charging Data Request and Charging Data Response are specified in clause 5.1.2.2.1 of TS 32.290.
Table 6.1.1.1-1 describes the use of these messages for network slice performance and analytics charging.
Message Source Destination
Charging Data RequestCEFCHF
Charging Data ResponseCHFCEF
The following clauses describe the different fields used in the Charging Data messages and the category in the tables is used according to the charging data configuration defined in clause 5.4 of TS 32.240.
Up

6.1.1.2  Charging Data Request messagep. 18

Table 6.1.1.2-1 illustrates the basic structure of a Charging Data Request message from the CEF as used for performance and analytics based charging.
Information Element Category for converged charging Description
Session IdentifierOCDescribed in TS 32.290.
Subscriber Identifier-This field is not applicable.
Tenant IdentifierOMThis field if present is the identifier of subscriber of network slice.
NF Consumer IdentificationMDescribed in TS 32.290.
NF FunctionalityMDescribed in TS 32.290.
NF NameOCDescribed in TS 32.290.
NF AddressOCDescribed in TS 32.290.
NF PLMN IDOCDescribed in TS 32.290.
Invocation TimestampMDescribed in TS 32.290.
Invocation Sequence Number-This field is not applicable.
Retransmission Indicator-This field is not applicable.
One-time EventOCDescribed in TS 32.290.
One-time Event TypeOCDescribed in TS 32.290.
Notify URI-This field is not applicable.
Service Specification InformationOCDescribed in TS 32.290.
TriggersOCDescribed in TS 32.290.
Multiple Unit Usage OMDescribed in TS 32.290, with the exception that quota management is not applicable.
Rating GroupMDescribed in TS 32.290
Requested Unit-This field is not applicable.
Used Unit ContainerOCDescribed in TS 32.290
Service Identifier-This field is not applicable.
Quota management Indicator-This field is not applicable.
TriggersOCThis field is described in TS 32.290 and holds the network slice performance and analytics specific triggers described in clause 5.2.1.
Trigger TimestampOCDescribed in TS 32.290
Time-This field is not applicable.
Total Volume-This field is not applicable.
Uplink Volume-This field is not applicable.
Downlink Volume-This field is not applicable.
Service Specific Unit-This field is not applicable.
Event Time Stamps-This field is not applicable.
Local Sequence Number OMDescribed in TS 32.290
NSPA Container Information OCThis field holds the network slice performance and analytics container specific information described in clause 6.2.1.3.
NSPA Charging InformationOCThis field holds the network slice information, which is reported to the CHF described in clause 6.2.1.2.
Up

6.1.1.3  Charging data response messagep. 19

Table 6.1.1.3-1 illustrates the basic structure of a Charging Data Response message from the CHF as used for performance and analytics based charging.
Information Element Category for converged charging Description
Session IdentifierOCDescribed in TS 32.290.
Invocation TimestampMDescribed in TS 32.290.
Invocation ResultOCDescribed in TS 32.290.
Invocation Sequence Number-This field is not applicable.
Session FailoverOCDescribed in TS 32.290.
Triggers -This field is not applicable.
Multiple Unit Information-This field is not applicable.
Up

6.1.2  Ga message contentsp. 19

Details of the Ga message contents are specified in TS 32.295.

6.1.3  CDR description on the Bns interfacep. 19

6.1.3.1  Generalp. 19

This clause describes the CDR content and format generated for performance and analytics based charging.
The following table provide a brief description of each CDR parameter. The category in the tables is used according to the charging data configuration defined in clause 5.4 of TS 32.240. Full definitions of the CDR parameters, sorted by the name in alphabetical order, are provided in TS 32.298.
Up

6.1.3.2  Network slice performance and analytics CHF CDR datap. 19

If enabled, network slice performance and analytics CDRs shall be produced for each network slice (i.e. S-NSSAI).
The fields of network slice performance and analytics CHF CDR are specified in Table 6.1.3.2-1.
Field Category Description
Record TypeMCHF record.
Recording Network Function IDOMThis field holds the name of the recording entity, i.e. the CHF id.
Tenant IdentifierOMThis field if present is the identifier of subscriber of network slice.
NF Consumer InformationMThis field holds the information of the CEF that used the charging service.
NF FunctionalityMThis field contains the function of the node (i.e. CEF)
NF NameOCThis field holds the name of the CEF used.
NF AddressOCThis field holds the IP Address of the CEF used.
NF PLMN IDOCThis field holds the PLMN identifier (MCC MNC) of the CEF.
List of Multiple Unit Usage OMThis field holds a list of changes in charging conditions for one single Network Slice Selection Assistance. The list is categorized per rating group. Each change is time stamped.
Rating GroupOMThis filed holds the rating group.
Used Unit ContainerOCThis field holds the information connected to the reported network slice.
TriggersOCThis field holds the reason for closing the used unit container.
Trigger TimestampOCThis field holds the timestamp of the trigger.
Local Sequence NumberMThis field holds the container sequence number.
NSPA Container InformationOCThis field holds the network slice performance and analytics container specific information described in clause 6.2.1.3.
NSPA Charging InformationOMThis field holds the network slice performance and analytics charging information defined in clause 6.2.1.2.
Record Opening TimeMDescribed in TS 32.298.
DurationMDescribed in TS 32.298.
Record Sequence NumberCDescribed in TS 32.298.
Cause for Record Closing MDescribed in TS 32.298.
Local Record Sequence NumberOMDescribed in TS 32.298.
Record ExtensionsOCDescribed in TS 32.298.
Up

6.2  Network slice performance and analytics charging specific parametersp. 20

6.2.1  Definition of network slice performance and analytics charging informationp. 20

6.2.1.1  Generalp. 20

The Charging Information parameter used for network slice performance and analytics charging is provided in the following clauses.

6.2.1.2  Definition of Performance and Analytics Charging Informationp. 20

Specific charging information used for network slice performance and analytics charging is provided within the Performance and Analytics Charging Information.
The detailed structure of the Performance and Analytics Charging Information can be found in Table 6.2.1.2-1.
Information Element Category Description
Single NSSAIMThis field holds network slice information the performance and analytics information belongs to.
Up

6.2.1.3  Definition of NSPA Container Informationp. 21

Specific charging information used for network slice performance and analytics charging is provided within the NSPA Container Information.
The detailed structure of the NSPA Charging Information can be found in Table 6.2.1.3-1.
Information Element Category Description
LatencyOCThis field holds latency as described in 28.554 [271].
ThroughputOCThis field holds throughput as described in TS 28.554
Maximum packet loss rateOCThis field holds maximum packet loss rate as described in TS GSMA NG.116 [500]
Service Experience statistics dataOCThis field holds service experience statistics data as described in TS 23.288
Number of PDU sessionsOCThis field holds the number of PDU sessions as described in TS 28.554.
Number of registered SubscribersOCThis field holds the number of registered subscribers as described in TS 28.554.
Load levelOCThis field holds the load level as described in TS 23.288.
Up

6.2.2  Formal network slice performance and analytics charging parameter descriptionp. 21

6.2.2.1  Network slice performance and analytics CHF CDR parametersp. 21

The detailed definitions, abstract syntax and encoding of network slice performance and analytics CHF CDRs parameters are specified in TS 32.298.

6.2.2.2  Network slice performance and analytics resources attributesp. 21

The detailed definitions of resources attributes used for network slice performance and analytics charging are specified in TS 32.291.

6.2.3  Detailed message format for converged chargingp. 21

The following clause specifies per Operation Type the charging data that are sent by CEF for network slice performance and analytics converged charging.
The Operation Types are listed in the following order: I (Initial)/T (Termination)/E (Event). Therefore, when all Operation Types are possible it is marked as ITE. If only some Operation Types are allowed for a node, only the appropriate letters are used (i.e. IT or E) as indicated in the Table heading. The omission of an Operation Type for a particular field is marked with "-" (i.e. I-E). Also, when an entire field is not allowed in a node the entire cell is marked as "-".
Table 6.2.3-1 defines the basic structure of the supported fields in the Charging Data Request message for CEF converged charging.
Information Element Analytics and Performance CEF
Supported Operation Types E
Session Identifier-
Subscriber Identifier-
Tenant IdentifierE
NF Consumer IdentificationE
Invocation TimestampE
Invocation Sequence Number-
Retransmission Indicator-
One-time EventE
One-time Event TypeE
Notify URI-
TriggersE
Multiple Unit UsageE
Rating GroupE
Used Unit ContainerE
TriggersE
NSPA Container Information E
NSPA Charging Information
Single NSSAIE
Table 6.2.3-2 defines the basic structure of the supported fields in the Charging Data Response message for CEF converged charging.
Information Element Analytics and Performance CEF
Supported Operation Types E
Session IdentifierE
Invocation TimestampE
Invocation ResultE
Invocation Sequence Number-
Session FailoverE
Triggers -
Multiple Unit information-
Up

6.3  Bindings for network slice performance and analytics converged chargingp. 22

This mapping between the Information Elements, resource attributes and CHF CDR parameters for network slice performance and analytics converged charging is described in clause 7 of TS 32.291.

$  Change historyp. 23