This Candidate Solution to Key Issue #1 proposes potential methods for collecting energy-related information on the UE and subsequently reporting it to the network, enhancements to the entities involved in obtaining relevant information, and the impact of them on taking into consideration the media context (e.g., the 5G Media Streaming System defined in
TS 26.501, 5G Multicast-Broadcast User Services as defined in
TS 26.502, the Real-time Media Communication System defined in
TS 26.506, split rendering Media Session Enabler as specified in
TS 26.565, etc. including UE-related energy information exposure.
Clause 6.2.8 of TS 23.288 envisages a set of high-level procedures by which data is collected by a Network Data Analytics Function (NWDAF) from UE Application(s) via an intermediary Direct Data Collection Client residing in the UE and an Application Function residing in the Data Network that provides an Event Exposure service to event consumers. A reference architecture satisfying these requirements in defined in
TS 26.531.
To obtain and maintain the UE energy-related information, a new generic functionality in the UE called the Energy-Related Information Collection and Reporting entity is defined within the Direct Data Collection Client as illustrated in
Figure 7.5.2.2.1-1. This entity is responsible for collecting and reporting energy-related information in the UE.
Based on the generic architecture for UE data collection, reporting and event exposure defined in
TS 26.531,
Figure 7.5.2.2.1-1 shows different interfaces between the UE and the Data Network, including the new UE Energy-Related Information Collection and Reporting functionality in the Direct Data Collection Client. In this case, UE energy-related information is reported to the Data Collection AF at reference point R2 for onward exposure to the NWDAF (at reference point R5) or to the Application Service Provider's Event Consumer AF (at reference point R6).
As described in
clause 4.1 of TS 26.531, the Data Collection AF is responsible for receiving data reports -the scope of which is extended by this candidate solution to include energy-related information reports - from UEs pertaining to a particular UE data domain, for processing the UE data contained in those reports, and for exposing them to subscribed event consumers in the form of events.
When the Direct Data Collection Client is instantiated in the 5G Media Streaming System per
clause 4.7.1 of TS 26.501, the UE Energy Related-Information Collection and Reporting functionality is a subfunction of the Media session Handler and plays the role of UE energy information collection and reporting to the Data Collection AF instantiated inside the 5GMS AF. This instantiation in the 5GMS architecture is illustrated in
Figure 7.5.2.2.2-1.